Frontal EEG for intensive care unit sedation: treating numbers or patients?

Peter V Sackey1.   

Abstract

In this issue of Critical Care, Dr Haenggi and co-workers present a study evaluating bispectral index (BIS), state entropy (SE) and response entropy in 44 patients sedated in the intensive care unit (ICU). As in recent studies attempting to correlate frontal electroencephalogram (EEG) measurements with clinical evaluations of sedative efficacy, there is considerable overlap in numerical EEG values and different clinical levels of sedation. This precludes the use of these monitors for monitoring or titrating sedation in the critically ill. Despite many attempts, no study has yet presented data showing improved outcome with the use of EEG monitors in ICU sedation. Meanwhile, clinical sedation protocols have emerged, improving important endpoints in critically ill patients needing sedation. A major underlying problem in applying EEG monitors in the ICU is that they have been developed for measuring anesthetic depth and the related risk of recall, rather than the acknowledged endpoints of sedation, namely reduction of anxiety and discomfort. Until an 'objective' monitor is developed to measure the degree of such symptoms, physicians should continue treating patients and not numbers.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18983711      PMCID: PMC2592758          DOI: 10.1186/cc7029

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


In this issue of Critical Care, Dr Haenggi and co-workers from Bern University Hospital present a study evaluating bispectral index (BIS), state entropy (SE) and response entropy (RE) during sedation in 44 patients in the intensive care unit (ICU) [1]. The authors used a meticulous protocol – with parallel SE, RE and BIS measurements, web camera monitoring and a computer program for noting sedative administration and interventions – to find a clinical indication for the use of entropy or BIS during ICU Ramsay Sedation Scale-targeted sedation. Statistically significant but poor correlation was found between the electroencephalogram (EEG) measurements and clinical assessment; correlation coefficients for RE and SE were -0.372 and -0.360, respectively. For BIS and clinical assessment the correlation coefficient was -0.426. These results, together with an overlap of entropy and BIS values between clinical sedation levels, led the authors to conclude that "BIS-Index or Entropy do not add information which can be used to guide sedation in the general ICU population." Other investigators have attempted to find correlation between EEG measurements of sedation and clinical parameters, similarly finding considerable overlap of displayed values between clinically different sedation levels and also close correlation with facial electromyographic activity [2-4]. The conclusions of these studies are identical to those of Dr Haenggi and co-workers, namely that BIS [2,3] and entropy [4] are not reliable in describing the level of sedation or guiding sedative administration in ICU patients. After more than a decade of use, the role of EEG parameters for sedation monitoring in the ICU is yet to be defined. For BIS – probably the most studied EEG parameter for ICU sedation – no study has yet shown clear benefit when used for sedation monitoring of ICU patients [5]. In contrast, new methods for clinical monitoring and titration of sedatives and analgesics have led to significant improvements in patient outcomes [6-8]. A daily wake-up test during sedation and mechanical ventilation has been shown to reduce time for mechanical ventilation and may also reduce ICU and hospital length of stay [7] and reduce complications of critical illness [9]. In a recent study, combining daily awakenings with spontaneous breathing tests additionally improved one-year survival, the effect probably depending on a lesser likelihood of oversedation [8]. Modifying sedation regimens may also modify patients memory panorama from the ICU and long-term psychological status [10,11]. It may be tempting to introduce plug-and-play EEG monitors for measuring anesthetic depth – such as BIS – in the ICU. The concept of a number on a monitor informing clinicians how to titrate drug doses for adequate sedation is appealing. The problem with applying BIS for ICU sedation is that it was not originally designed to detect the main indications for sedative administration, namely discomfort and anxiety [12]. The anesthesia end-point that BIS primarily was developed to target and is marketed for [13] – amnesia – may not be a valid end-point for ICU sedation. Amnesia from the ICU is not necessarily a good thing [14]. Furthermore, given the data from the study and previous studies of BIS in ICU sedation, aiming for a target BIS-interval in ICU patients would likely lead to clinical problems of under- or oversedation in individual patients [1-4]. Acknowledged endpoints of ICU sedation are rather optimal patient comfort and safety [12]. EEG measures may not reflect the efficacy of sedation or analgesia with regard to these endpoints. The previously prevailing idea of sleep being necessary for comfort in ICU patients may have emanated from transferring the anesthesia endpoint – hypnosis – from the operating room into the ICU, at a time when mechanical ventilation was less refined than it is today. New ventilators with more patient-friendly modes of ventilation may cause less patient-ventilator dysynchrony during light to moderate sedation, thereby potentially reducing sedative requirements. The development of new analgosedation concepts highlight this quandary of old and new sedation end-points in ICU patients [15,16]. While EEG monitoring in patients receiving neuromuscular blocking treatment may be of some value given the lack of other methods for monitoring sedation depth [5], there is presently no evidence or rationale for the use of BIS or entropy in monitoring or titrating sedation of ICU patients. A number on a monitor indicating 'adequate sedation' can not replace the common sense of sedating a patient with clinical signs of discomfort or agitation, or reducing sedation in a unresponsive patient, unless patient outcome studies prove such an approach to be successful. The reasonable current sedation end-point should not, therefore, be deep sedation, a certain BIS or entropy value, but rather patient comfort and safety. Before considering new monitors for ICU sedation, we need to be confident that they make a difference in these end-points. For now, let's treat patients and not numbers.

Abbreviations

BIS: bispectral index; EEG: electroencephalogram; ICU: intensive care unit; RE: response entropy; SE: state entropy.

Competing interests

The author declares that he has no competing interests.
  15 in total

1.  Clinical practice guidelines for the sustained use of sedatives and analgesics in the critically ill adult.

Authors:  Judith Jacobi; Gilles L Fraser; Douglas B Coursin; Richard R Riker; Dorrie Fontaine; Eric T Wittbrodt; Donald B Chalfin; Michael F Masica; H Scott Bjerke; William M Coplin; David W Crippen; Barry D Fuchs; Ruth M Kelleher; Paul E Marik; Stanley A Nasraway; Michael J Murray; William T Peruzzi; Philip D Lumb
Journal:  Crit Care Med       Date:  2002-01       Impact factor: 7.598

2.  The long-term psychological effects of daily sedative interruption on critically ill patients.

Authors:  John P Kress; Brian Gehlbach; Maureen Lacy; Neil Pliskin; Anne S Pohlman; Jesse B Hall
Journal:  Am J Respir Crit Care Med       Date:  2003-10-02       Impact factor: 21.405

3.  Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation.

Authors:  A D Brook; T S Ahrens; R Schaiff; D Prentice; G Sherman; W Shannon; M H Kollef
Journal:  Crit Care Med       Date:  1999-12       Impact factor: 7.598

4.  Memory, delusions, and the development of acute posttraumatic stress disorder-related symptoms after intensive care.

Authors:  C Jones; R D Griffiths; G Humphris; P M Skirrow
Journal:  Crit Care Med       Date:  2001-03       Impact factor: 7.598

5.  Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation.

Authors:  J P Kress; A S Pohlman; M F O'Connor; J B Hall
Journal:  N Engl J Med       Date:  2000-05-18       Impact factor: 91.245

6.  A comparison of hypnotic and analgesic based sedation in a general intensive care unit.

Authors:  G Park; M Lane; S Rogers; P Bassett
Journal:  Br J Anaesth       Date:  2007-01       Impact factor: 9.166

7.  How reliable is the Bispectral Index in critically ill patients? A prospective, comparative, single-blinded observer study.

Authors:  Stanley A Nasraway SA; Eugene C Wu; Ruth M Kelleher; Cynthia M Yasuda; Anne M Donnelly
Journal:  Crit Care Med       Date:  2002-07       Impact factor: 7.598

8.  Bispectral index as a predictor of sedation depth during isoflurane or midazolam sedation in ICU patients.

Authors:  P V Sackey; P J Radell; F Granath; C R Martling
Journal:  Anaesth Intensive Care       Date:  2007-06       Impact factor: 1.669

Review 9.  Role of the bispectral index in sedation monitoring in the ICU.

Authors:  Jaclyn M LeBlanc; Joseph F Dasta; Sandra L Kane-Gill
Journal:  Ann Pharmacother       Date:  2006-02-21       Impact factor: 3.154

10.  Daily interruption of sedative infusions and complications of critical illness in mechanically ventilated patients.

Authors:  William D Schweickert; Brian K Gehlbach; Anne S Pohlman; Jesse B Hall; John P Kress
Journal:  Crit Care Med       Date:  2004-06       Impact factor: 7.598

View more
  5 in total

1.  Long-term sedation in intensive care unit: a randomized comparison between inhaled sevoflurane and intravenous propofol or midazolam.

Authors:  Malcie Mesnil; Xavier Capdevila; Sophie Bringuier; Pierre-Olivier Trine; Yoan Falquet; Jonathan Charbit; Jean-Paul Roustan; Gerald Chanques; Samir Jaber
Journal:  Intensive Care Med       Date:  2011-03-29       Impact factor: 17.440

2.  Feasibility of continuous sedation monitoring in critically ill intensive care unit patients using the NeuroSENSE WAVCNS index.

Authors:  Nicholas West; Paul B McBeth; Sonia M Brodie; Klaske van Heusden; Sarah Sunderland; Guy A Dumont; Donald E G Griesdale; J Mark Ansermino; Matthias Görges
Journal:  J Clin Monit Comput       Date:  2018-02-20       Impact factor: 2.502

3.  Automated sedation outperforms manual administration of propofol and remifentanil in critically ill patients with deep sedation: a randomized phase II trial.

Authors:  Morgan Le Guen; Ngai Liu; Eric Bourgeois; Thierry Chazot; Daniel I Sessler; Jean-Jacques Rouby; Marc Fischler
Journal:  Intensive Care Med       Date:  2012-12-06       Impact factor: 17.440

4.  Adaptive Sedation Monitoring From EEG in ICU Patients With Online Learning.

Authors:  Wei-Long Zheng; Haoqi Sun; Oluwaseun Akeju; M Brandon Westover
Journal:  IEEE Trans Biomed Eng       Date:  2019-09-23       Impact factor: 4.538

5.  Automated tracking of level of consciousness and delirium in critical illness using deep learning.

Authors:  Haoqi Sun; Eyal Kimchi; Oluwaseun Akeju; Sunil B Nagaraj; Lauren M McClain; David W Zhou; Emily Boyle; Wei-Long Zheng; Wendong Ge; M Brandon Westover
Journal:  NPJ Digit Med       Date:  2019-09-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.