Literature DB >> 18983317

Influence of microgap location and configuration on the periimplant bone morphology in submerged implants. An experimental study in dogs.

Dietmar Weng1, Maria José Hitomi Nagata, Matthias Bell, Alvaro Francisco Bosco, Luiz Gustavo Nascimento de Melo, Ernst-Jürgen Richter.   

Abstract

OBJECTIVES: The vertical location of the implant-abutment connection influences the periimplant bone morphology. It is unknown, however, whether different microgap configurations cause different bone reactions. Therefore, in this study the bone morphologies of two different implant systems were compared.
MATERIAL AND METHODS: Three months after tooth extraction in eight mongrel dogs, two grit-blasted screw implants with internal Morse taper connection (ANK group) were placed on one side whereas the contralateral side received two oxidized screw implants with external hex (TIU group). One implant on each side was placed level with the bone (equicrestal), the second implant was inserted 1.5 mm below bone level (subcrestal). After 3 months the implants were uncovered. Three months after stage two surgery, histometrical evaluations were performed in order to assess the periimplant bone levels (PBL), the first bone-to-implant contact points (BICP), the width (HBD) and the steepness (SLO) of the bone defect.
RESULTS: All implants osseointegrated clinically and histologically. Bone overgrowth of the microgap was seen in ANK implants only. No significant differences between ANK and TIU could be detected in neither vertical position for PBL and BICP. However, a tendency in favor of ANK was visible when the implants were placed subcrestally. In the parameters HBD (ANK equicrestal -0.23 mm; TIU equicrestal -0.51 mm; ANK subcrestal +0.19 mm; TIU subcrestal -0.57 mm) and SLO (ANK equicrestal 35.36 degrees; TIU equicrestal 63.22 degrees; ANK subcrestal 20.40 degrees; TIU subcrestal 44.43 degrees) more pronounced and significant differences were noted.
CONCLUSIONS: Within the limits of this study, it is concluded that different microgap designs cause different shapes and sizes of the periimplant ('dish-shaped') bone defect in submerged implants both in equicrestal and subcrestal positions.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18983317     DOI: 10.1111/j.1600-0501.2008.01564.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  16 in total

1.  Assessment of lipopolysaccharide microleakage at conical implant-abutment connections.

Authors:  Sönke Harder; Elgar Susanne Quabius; Lars Ossenkop; Matthias Kern
Journal:  Clin Oral Investig       Date:  2011-12-02       Impact factor: 3.573

2.  A retrospective study of implant-abutment connections on crestal bone level.

Authors:  M-I Lin; Y-W Shen; H-L Huang; J-T Hsu; L-J Fuh
Journal:  J Dent Res       Date:  2013-10-24       Impact factor: 6.116

3.  In vitro synchrotron-based radiography of micro-gap formation at the implant-abutment interface of two-piece dental implants.

Authors:  A Rack; T Rack; M Stiller; H Riesemeier; S Zabler; K Nelson
Journal:  J Synchrotron Radiat       Date:  2010-02-03       Impact factor: 2.616

Review 4.  Influence of subcrestal implant placement compared with equicrestal position on the peri-implant hard and soft tissues around platform-switched implants: a systematic review and meta-analysis.

Authors:  Cristina Valles; Xavier Rodríguez-Ciurana; Marco Clementini; Mariana Baglivo; Blanca Paniagua; Jose Nart
Journal:  Clin Oral Investig       Date:  2018-01-08       Impact factor: 3.573

5.  Nasal floor augmentation for the reconstruction of the atrophic maxilla: a case series.

Authors:  Moustafa El-Ghareeb; Joan Pi-Anfruns; Mohammed Khosousi; Tara Aghaloo; Peter Moy
Journal:  J Oral Maxillofac Surg       Date:  2011-12-16       Impact factor: 1.895

Review 6.  Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? A systematic review.

Authors:  Marcelo Coelho Goiato; Eduardo Piza Pellizzer; Emily Vivianne Freitas da Silva; Liliane da Rocha Bonatto; Daniela Micheline dos Santos
Journal:  Oral Maxillofac Surg       Date:  2015-04-25

7.  Retrospective Clinical Study of Marginal Bone Level Changes with Two Different Screw-Implant Types: Comparison Between Tissue Level (TE) and Bone Level (BL) Implant.

Authors:  Vinay V Kumar; Keyvan Sagheb; Peer W Kämmerer; Bilal Al-Nawas; Wilfried Wagner
Journal:  J Maxillofac Oral Surg       Date:  2013-06-11

8.  Effects of Implant-Abutment Connection Type and Inter-Implant Distance on Inter-Implant Bone Stress and Microgap: Three-Dimensional Finite Element Analysis.

Authors:  Takashi Matsuoka; Tamaki Nakano; Satoshi Yamaguchi; Shinji Ono; Shota Watanabe; Takumi Sato; Hirofumi Yatani
Journal:  Materials (Basel)       Date:  2021-05-06       Impact factor: 3.623

9.  Ligature-induced peri-implant infection in crestal and subcrestal implants: a clinical and radiographic study in dogs.

Authors:  Baoxin Huang; Muzi Piao; Li Zhang; Xian'e Wang; Li Xu; Weidong Zhu; Huanxin Meng
Journal:  PeerJ       Date:  2015-07-30       Impact factor: 2.984

10.  Evaluation of the success criteria for zirconia dental implants: a four-year clinical and radiological study.

Authors:  Andrea Enrico Borgonovo; Rachele Censi; Virna Vavassori; Marcello Dolci; Josè Luis Calvo-Guirado; Rafael Arcesio Delgado Ruiz; Carlo Maiorana
Journal:  Int J Dent       Date:  2013-08-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.