| Literature DB >> 18979817 |
W H Greene1, S Chelikani, K Purushothaman, Z Chen, J P S Knisely, L H Staib, X Papademetris, J Duncan.
Abstract
A constrained non-rigid registration (CNRR) algorithm for use in updating prostate external beam image-guided radiotherapy treatment plans is presented in this paper. The developed algorithm is based on a multi-resolution cubic B-spline FFD transformation and has been tested and verified using 3D CT images from 10 sets of real patient data acquired from 4 different patients on different treatment days. The registration can be constrained to any combination of the prostate, rectum, bladder, pelvis, left femur, and right femur. The CNRR was tested with 5 different combinations of constraints and each test significantly outperformed both rigid and non-rigid registration at aligning constrained bones and critical organs. The CNRR was then used to update the treatment plans to account for articulated, rigid bone motion and non-rigid organ deformation. Each updated treatment plan outperformed the original treatment plan by increasing radiation dosage to the prostate and lowering radiation dosage to the rectum and bladder.Entities:
Mesh:
Year: 2008 PMID: 18979817 PMCID: PMC2790815 DOI: 10.1007/978-3-540-85988-8_93
Source DB: PubMed Journal: Med Image Comput Comput Assist Interv