Literature DB >> 18977332

Automated measurement of urinary creatinine by multichannel kinetic spectrophotometry.

Shin-Ichi Ohira1, Andrea B Kirk, Purnendu K Dasgupta.   

Abstract

Urinary creatinine analysis is required for clinical diagnosis, especially for evaluation of renal function. Creatinine adjustment is also widely used to estimate 24-h excretion from spot samples. Few convenient validated approaches are available for in-house creatinine measurement for small- to medium-scale studies. Here we apply the Jáffe reaction to creatinine determination with zone fluidic multichannel kinetic spectrophotometry. Diluted urine sample and reagent, alkaline picric acid, were mixed by a computer-programmed dispenser and rapidly delivered to a four-channel detection cell. The absorbance change was monitored by a flow-through light-emitting diode-photodiode-based detector. Validation results against high-performance liquid chromatography-ultraviolet (HPLC-UV)/mass spectrometry (MS) are presented. Responses for 10-fold diluted samples were linear within clinically relevant ranges (0-250 mg/L after dilution). The system can analyze 70 samples per hour with a limit of detection of 0.76 mg/L. The relative standard deviation was 1.29% at 100 mg/L creatinine (n=225). Correlation with the HPLC (UV quantitation/MS confirmation) system was excellent (linear, r2=0.9906). The developed system allows rapid, simple, cost-effective, and robust creatinine analysis and is suitable for the analysis of large numbers of urine samples.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18977332     DOI: 10.1016/j.ab.2008.10.015

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  3 in total

1.  Prenatal exposure to inflammation induced by zymosan results in activation of intrarenal renin-angiotensin system in adult offspring rats.

Authors:  Xue-Qin Hao; Hai-Gang Zhang; Shu-Hui Li; Yi Jia; Ya Liu; Jian-Zhi Zhou; Yan-Ling Wei; Li-Yun Hao; Yuan Tang; Min Su; Xiao-Hui Li
Journal:  Inflammation       Date:  2010-12       Impact factor: 4.092

2.  Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis.

Authors:  Thitirat Mantim; Korbua Chaisiwamongkhol; Kanchana Uraisin; Peter C Hauser; Prapin Wilairat; Duangjai Nacapricha
Journal:  Molecules       Date:  2020-05-13       Impact factor: 4.411

3.  Fluorimetric Method for the Determination of Histidine in Random Human Urine Based on Zone Fluidics.

Authors:  Antonios Alevridis; Apostolia Tsiasioti; Constantinos K Zacharis; Paraskevas D Tzanavaras
Journal:  Molecules       Date:  2020-04-04       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.