Literature DB >> 18977115

Analysis of retrieved ultra-high-molecular-weight polyethylene tibial components from rotating-platform total knee arthroplasty.

Ryan M Garcia1, Matthew J Kraay, Patrick J Messerschmitt, Victor M Goldberg, Clare M Rimnac.   

Abstract

Mobile-bearing total knee Arthroplasties (TKAs) were designed to increase conformity, decrease contact stresses, and decrease polyethylene damage. Our objective was to evaluate the performance of retrieved mobile-bearing TKAs with respect to wear damage of the polyethylene in a series of components obtained at revision surgery. Tibial component polyethylene superior and inferior surface damage and radiographic radiolucency analysis was conducted on 40 retrieved mobile-bearing TKAs. Higher levels of superior articulating surface damage were found to be associated with higher levels of inferior surface damage in this retrieval study. Greater levels of damage were present on both surfaces in components with greater radiographic radiolucency scores and mechanically loose components. The mobile-bearing TKA remains vulnerable to polyethylene wear damage at the superior surface and introduces an independent inferior surface also vulnerable to wear damage.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18977115     DOI: 10.1016/j.arth.2008.01.003

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  Knee wear measured in retrievals: a polished tray reduces insert wear.

Authors:  Daniel J Berry; John H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

Review 2.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

3.  Wear damage in mobile-bearing TKA is as severe as that in fixed-bearing TKA.

Authors:  Natalie H Kelly; Rose H Fu; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

4.  Rotating-platform has no surface damage advantage over fixed-bearing TKA.

Authors:  Kirsten Stoner; Seth A Jerabek; Stephanie Tow; Timothy M Wright; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

5.  Can microcomputed tomography measure retrieved polyethylene wear? Comparing fixed-bearing and rotating-platform knees.

Authors:  Charles A Engh; Rebecca L Zimmerman; Robert H Hopper; Gerard A Engh
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

6.  Does increased topside conformity in modular total knee arthroplasty lead to increased backside wear?

Authors:  Ran Schwarzkopf; Richard D Scott; Evan M Carlson; John H Currier
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

7.  An autonomous mathematical reconstruction to effectively measure volume loss on retrieved polyethylene tibial inserts.

Authors:  Christopher B Knowlton; Markus A Wimmer
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2012-08-22       Impact factor: 3.368

8.  Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty.

Authors:  Tao Cheng; Guoyou Zhang; Xianlong Zhang
Journal:  Acta Orthop       Date:  2011-09-06       Impact factor: 3.717

  8 in total