Literature DB >> 18973986

High-resolution ultrasound speckle tracking may detect vascular mechanical wall changes in peripheral artery bypass vein grafts.

William F Weitzel1, Kang Kim, Peter K Henke, Jonathan M Rubin.   

Abstract

We report the use of high-resolution, phase-sensitive ultrasound speckle tracking to measure the local vessel-wall strain in two subjects with artery-vein bypass grafts. In addition, we combined this technique with a free-hand pressure equalization procedure to elucidate the nonlinear effects of blood pressure on vessel wall compliance. While conventional ultrasound imaging can be used to elucidate the mechanical properties of tissues within the body, it is constrained by comparatively lower resolution and inferential, rather than direct, measurements of strain and by the small strain normally produced under physiological pressure in highly nonlinear structures such as arteries. One of our subjects was examined both before and after developing stenosis 3 months postsurgery. The strain values for this individual were found to be significantly lower, indicating a stiffer vessel wall at the stenotic region than at a nonstenotic region under both physiological and equalized pressure. These results suggest the possibility of noninvasive detection of neointimal hyperplasia preceding anastomotic stenosis.

Entities:  

Mesh:

Year:  2008        PMID: 18973986      PMCID: PMC2736955          DOI: 10.1016/j.avsg.2008.08.031

Source DB:  PubMed          Journal:  Ann Vasc Surg        ISSN: 0890-5096            Impact factor:   1.466


  24 in total

1.  Arterial pulse wave velocity with tissue Doppler imaging.

Authors:  A Eriksson; E Greiff; T Loupas; M Persson; P Pesque
Journal:  Ultrasound Med Biol       Date:  2002-05       Impact factor: 2.998

2.  Adaptive strain estimation using retrospective processing [medical US elasticity imaging.

Authors:  M A Lubinski; S Y Emelianov; M O'Donnell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

3.  Deformation models and correlation analysis in elastography.

Authors:  M Bilgen; M F Insana
Journal:  J Acoust Soc Am       Date:  1996-05       Impact factor: 1.840

4.  In vivo human brachial artery elastic mechanics: effects of smooth muscle relaxation.

Authors:  A J Bank; D R Kaiser; S Rajala; A Cheng
Journal:  Circulation       Date:  1999-07-06       Impact factor: 29.690

5.  Reduction of image noise in elastography.

Authors:  I Céspedes; J Ophir
Journal:  Ultrason Imaging       Date:  1993-04       Impact factor: 1.578

6.  The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new model.

Authors:  G J Langewouters; K H Wesseling; W J Goedhard
Journal:  J Biomech       Date:  1984       Impact factor: 2.712

7.  Peripheral arterial disease detection, awareness, and treatment in primary care.

Authors:  A T Hirsch; M H Criqui; D Treat-Jacobson; J G Regensteiner; M A Creager; J W Olin; S H Krook; D B Hunninghake; A J Comerota; M E Walsh; M M McDermott; W R Hiatt
Journal:  JAMA       Date:  2001-09-19       Impact factor: 56.272

8.  Femoral artery wall thickness and stiffness in evaluation of peripheral vascular disease in type 2 diabetes mellitus.

Authors:  H Taniwaki; T Shoji; M Emoto; T Kawagishi; E Ishimura; M Inaba; Y Okuno; Y Nishizawa
Journal:  Atherosclerosis       Date:  2001-09       Impact factor: 5.162

9.  Renal advances in ultrasound elasticity imaging: measuring the compliance of arteries and kidneys in end-stage renal disease.

Authors:  W F Weitzel; K Kim; J M Rubin; H Xie; M O'Donnell
Journal:  Blood Purif       Date:  2005       Impact factor: 2.614

10.  Impact of aortic stiffness on survival in end-stage renal disease.

Authors:  J Blacher; A P Guerin; B Pannier; S J Marchais; M E Safar; G M London
Journal:  Circulation       Date:  1999-05-11       Impact factor: 29.690

View more
  5 in total

1.  Venous elastography: validation of a novel high-resolution ultrasound method for measuring vein compliance using finite element analysis.

Authors:  Rohan Biswas; Prashant Patel; Dae W Park; Thomas J Cichonski; Michael S Richards; Jonathan M Rubin; James Hamilton; William F Weitzel
Journal:  Semin Dial       Date:  2010 Jan-Feb       Impact factor: 3.455

2.  An Open-Source Ultrasound Software for Diagnosis of Fistula Maturation.

Authors:  Barry Belmont; Dae Woo Park; William F Weitzel; Albert J Shih
Journal:  ASAIO J       Date:  2018 Jan/Feb       Impact factor: 2.872

3.  Hemodynamic Shear Stress and Endothelial Dysfunction in Hemodialysis Access.

Authors:  Michelle K Fitts; Daniel B Pike; Kasey Anderson; Yan-Ting Shiu
Journal:  Open Urol Nephrol J       Date:  2014

4.  Angioplasty Induced Changes in Dialysis Vascular Access Compliance.

Authors:  Yihao Zheng; Brian J Thelen; Nirmala Rajaram; Venkataramu N Krishnamurthy; James Hamilton; Miguel Angel Funes-Lora; Timothy Morgan; Lenar Yessayan; Brandie Bishop; Nickolas Osborne; Peter Henke; Albert J Shih; William F Weitzel
Journal:  Ann Biomed Eng       Date:  2021-08-11       Impact factor: 3.934

5.  Characterization of vascular strain during in-vitro angioplasty with high-resolution ultrasound speckle tracking.

Authors:  Prashant Patel; Rohan Biswas; Daewoo Park; Thomas J Cichonski; Michael S Richards; Jonathan M Rubin; Sem Phan; James Hamilton; William F Weitzel
Journal:  Theor Biol Med Model       Date:  2010-08-20       Impact factor: 2.432

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.