Literature DB >> 18970784

Fast simultaneous spectrophotometric determination of naphazoline nitrate and methylparaben by sequential injection chromatography.

Petr Chocholous1, Dalibor Satínský, Petr Solich.   

Abstract

Fast simultaneous determination of naphazoline nitrate and methylparaben in pharmaceuticals using separation method based on a novel reversed-phase sequential injection chromatography (SIC) is described in this contribution as an alternative to classical HPLC. A Chromolithtrade mark Flash RP-18e (25mmx4.6mm) column (Merck((R)), Germany) and a FIAlab((R)) 3000 system (USA) with a six-port selection valve and 5.0ml syringe pump were used for sequential injection chromatographic separations in our study. The mobile phase used was methanol/water (40:65, v/v), pH 5.2 adjusted with triethylamine 0.8mulml(-1) and acetic acid, at flow rate 0.9mlmin(-1). UV detection provided by DAD detector and two wavelengths were simultaneously monitored for increasing sensitivity of determination. Detector was set up at 220nm for naphazoline nitrate and 256nm for methylparaben and ethylparaben (IS). There is no necessity to use pre-adjustment of sample of nasal drops (only dilution with mobile phase) so the time of the whole analysis is very short. The validation parameters have shown good results: linearity of determination for both components (naphazoline nitrate and methylparaben), correlation coefficient >0.999; repeatability of determination (R.S.D.) in the range 0.5-1.6% at three different concentration levels, detection limits 0.02mugml(-1) (naphazoline nitrate) and 0.20mugml(-1) (methylparaben and ethylparaben), and recovery from the pharmaceutical preparations in the range 100.06-102.55%. The chromatographic resolution between peaks of compounds was more than 4.0 and analysis time was less than 4min under the optimal conditions. The advantages and drawbacks of SIC against classical HPLC are discussed showing that SIC can be an advantageous alternative in many cases.

Entities:  

Year:  2006        PMID: 18970784     DOI: 10.1016/j.talanta.2006.02.065

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  A validated stability-indicating HPLC method for the simultaneous determination of pheniramine maleate and naphazoline hydrochloride in pharmaceutical formulations.

Authors:  Taomin Huang; Nianzu Chen; Donglei Wang; Yonghua Lai; Zhijuan Cao
Journal:  Chem Cent J       Date:  2014-02-01       Impact factor: 4.215

2.  In situ modified screen printed and carbon paste ion selective electrodes for potentiometric determination of naphazoline hydrochloride in its formulation.

Authors:  Gehad G Mohamed; F A Nour El-Dien; Eman Y Z Frag; Marwa El-Badry Mohamed
Journal:  J Pharm Anal       Date:  2013-04-10

3.  Determination of naphazoline HCl, pheniramine maleate and their official impurities in eye drops and biological fluid rabbit aqueous humor by a validated LC-DAD method.

Authors:  Khadiga M Kelani; Maha A Hegazy; Amal M Hassan; Mahmoud A Tantawy
Journal:  RSC Adv       Date:  2021-02-10       Impact factor: 3.361

4.  A green TLC densitometric method for the simultaneous detection and quantification of naphazoline HCl, pheniramine maleate along with three official impurities.

Authors:  Khadiga M Kelani; Maha A Hegazy; Amal M Hassan; Mahmoud A Tantawy
Journal:  BMC Chem       Date:  2022-04-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.