A critical examination of the components of the Schlieren effect in flow analysis.

Ana Cristi B Dias1, Eduardo P Borges, Elias A G Zagatto, Paul J Worsfold.   

Abstract

The Schlieren effect is a consequence of light inflexions altering the spectrophotometric measurements that are due to the formation of optical artefacts such as mirror and lenses inside the flowing sample. It may influence signal-to-noise ratio, sample throughput and measurement repeatability in spectrophotometric flow-based procedures. It was critically examined, in order to provide guidelines for system design. Results demonstrate that the magnitude of the Schlieren effect is governed by the combined influence of two components. The first is related to loss of light by reflection at sharp liquid interfaces and prevails under poor mixing conditions. In this situation the transmitted light becomes more intense and somewhat erratic. The second is related to light refraction in regions with pronounced refractive index gradients, and prevails under good mixing conditions. It can lead to positive or negative modifications of the transmitted light, the direction being dependent on the relevance of these components. The importance of the solubility of the chemical species involved, the possibility of interactions with the inner wall of the tubing, and the feasibility of dual-wavelength spectrophotometry for compensating purposes are discussed.

Year:  2005        PMID: 18970434     DOI: 10.1016/j.talanta.2005.06.071

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  FIA-coupled spectrophotometric method for determination of Cr (VI) traces in natural waters: application of in-line dissolution of 1,5-diphenylcarbazide after heat treatment and activated alumina as adsorbent for preconcentration.

Authors:  Diogenes Meneses; José Guimarães F Júnior; Paulo Cesar Costa de Oliveira
Journal:  Environ Monit Assess       Date:  2018-09-28       Impact factor: 2.513

2.  Improvement of On-Site Sensor for Simultaneous Determination of Phosphate, Silicic Acid, Nitrate plus Nitrite in Seawater.

Authors:  Mahmoud Fatehy Altahan; Mario Esposito; Eric P Achterberg
Journal:  Sensors (Basel)       Date:  2022-05-03       Impact factor: 3.847

3.  Sequential Injection System for Analysis of Degree Brix, Orthophosphate and pH in Raw Sugarcane Juice Applicable to Sugar Industry.

Authors:  Phoonthawee Saetear; Nattinee Saechua; Kamonthip Sereenonchai
Journal:  Molecules       Date:  2021-10-27       Impact factor: 4.411

Review 4.  Chemical Derivatization in Flow Analysis.

Authors:  Fábio R P Rocha; Elias A G Zagatto
Journal:  Molecules       Date:  2022-02-26       Impact factor: 4.411

5.  Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis.

Authors:  Thitirat Mantim; Korbua Chaisiwamongkhol; Kanchana Uraisin; Peter C Hauser; Prapin Wilairat; Duangjai Nacapricha
Journal:  Molecules       Date:  2020-05-13       Impact factor: 4.411

6.  The Automation Technique Lab-In-Syringe: A Practical Guide.

Authors:  Burkhard Horstkotte; Petr Solich
Journal:  Molecules       Date:  2020-04-01       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.