Literature DB >> 18970145

Synthesis and application of a functionalized resin for flow injection/F AAS copper determination in waters.

Ricardo J Cassella1, Otto I B Magalhães, Marcos Tadeu Couto, Edson Luiz S Lima, Marcia Angélica F S Neves, Fernanda Margarida B Coutinho.   

Abstract

This paper reports the development of a new strategy for low-level determination of copper in water samples by using a flow-injection system coupled to solid-phase extraction (SPE) using flame atomic absorption spectrometry (F AAS) as detector. In order to preconcentrate copper from samples, a minicolumn packed with a styrene-divinylbenzene resin functionalized with (S)-2-[hydroxy-bis-(4-vinyl-phenyl)-methyl]-pyrrolidine-1-carboxylic acid ethyl ester was used and the synthesis procedure is described. System operation is based on the on-line retention of Cu(II) ions at pH 9.0+/-0.2 in a such minicolumn with posterior analyte elution with 2moll(-1) HCl directly to the F AAS nebulizer. The influence of several chemical (sample pH, buffer concentration, HCl eluent concentration and effect of the ionic strength) and flow (sample and eluent flow rates and preconcentration time) variables that could affect the performance of this system were investigated as well as the possible interferents. At optimized conditions, for 2min of preconcentration time (13.2ml of sample volume), the system achieved a detection limit of 1.1mugl(-1), a R.S.D. 1% at 20muggl(-1) and an analytical throughput of 25h(-1), whereas for 4min of preconcentration time (26.4ml of sample volume), a detection limit of 0.93mugl(-1), a R.S.D. 5.3% at 5mugl(-1) and a sampling frequency of 13h(-1) were reported.

Entities:  

Year:  2005        PMID: 18970145     DOI: 10.1016/j.talanta.2005.02.019

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  9 in total

Review 1.  Metal Cation Detection in Drinking Water.

Authors:  Johnson Dalmieda; Peter Kruse
Journal:  Sensors (Basel)       Date:  2019-11-23       Impact factor: 3.576

2.  Highly sensitive and selective determination of copper(II) based on a dual catalytic effect and by using silicon nanoparticles as a fluorescent probe.

Authors:  Xiaogen Chen; Qiujun Lu; Dan Liu; Cuiyan Wu; Meiling Liu; Haitao Li; Youyu Zhang; Shouzhuo Yao
Journal:  Mikrochim Acta       Date:  2018-02-19       Impact factor: 5.833

3.  C-Phycoerythrin as a Colorimetric and Fluorometric Probe for the Sensitive, Selective and Quantitative Detection of Cu2+ in Aqueous Samples.

Authors:  Tonmoy Ghosh; Apeksha Vyas; Khushbu Bhayani; Sandhya Mishra
Journal:  J Fluoresc       Date:  2018-04-18       Impact factor: 2.217

4.  Amino acid-functionalized carbon quantum dots for selective detection of Al3+ ions and fluorescence imaging in living cells.

Authors:  Chaoren Yan; Liulong Guo; Xu Shao; Qi Shu; Ping Guan; Jingwei Wang; Xiaoling Hu; Chaoli Wang
Journal:  Anal Bioanal Chem       Date:  2021-04-28       Impact factor: 4.142

5.  Functional ZnS:Mn(II) quantum dot modified with L-cysteine and 6-mercaptonicotinic acid as a fluorometric probe for copper(II).

Authors:  Jiangru Wang; Jialuo Yu; Xiaoyan Wang; Liyan Wang; Bowei Li; Dazhong Shen; Qi Kang; Lingxin Chen
Journal:  Mikrochim Acta       Date:  2018-08-18       Impact factor: 5.833

6.  Highly Selective Sensing of Li+ in H2O/CH3CN via Fluorescence 'Turn-on' Response of a Coumarin-Indole Linked Dyad: an Experimental and Theoretical Study.

Authors:  Santosh Kumari; Sunita Joshi; Amrit Sarmah; Debi Pant; Rajeev Sakhuja
Journal:  J Fluoresc       Date:  2016-08-27       Impact factor: 2.217

7.  Schiff Base Derived from 4,4'-methylenedianiline and p-anisaldehyde: Colorimetric Sensor for Cu2+, Paper Strip Sensor for Al3+ and Fluorescent Sensor for Pb2.

Authors:  Diganta Kumar Das; Satyapriya Deka; Ankur Kanti Guha
Journal:  J Fluoresc       Date:  2019-11-30       Impact factor: 2.217

8.  Highly sensitive and selective colorimetric and off-on fluorescent reversible chemosensors for Al³⁺ based on the rhodamine fluorophore.

Authors:  Naveen Mergu; Ashok Kumar Singh; Vinod Kumar Gupta
Journal:  Sensors (Basel)       Date:  2015-04-17       Impact factor: 3.576

9.  Single-Piece Solid Contact Cu2+-Selective Electrodes Based on a Synthesized Macrocyclic Calix[4]arene Derivative as a Neutral Carrier Ionophore.

Authors:  Abd El-Galil E Amr; Mohamed A Al-Omar; Ayman H Kamel; Elsayed A Elsayed
Journal:  Molecules       Date:  2019-03-06       Impact factor: 4.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.