Literature DB >> 18970017

Speciation of arsenic(III) and arsenic(V) by inductively coupled plasma-atomic emission spectrometry coupled with preconcentration system.

Kritsana Jitmanee1, Mitsuko Oshima, Shoji Motomizu.   

Abstract

A novel and simple flow-based method was developed for the simultaneous determination of As(III) and As(V) in freshwater samples. Two miniature columns with a solid phase anion exchange resin, placed on two 6-way valves were utilized for the solid-phase collection/concentration of arsenic(III) and arsenic(V), respectively. As(III) could be retained on the column after its oxidation to As(V) species with an oxidizing agent. The collected analytes were then sequentially eluted by 2M nitric acid and introduced into ICP-AES. Potassium permanganate was examined as potential oxidizing agent for conversion of As(III) to As(V). The standard deviation of the analytical signals (peak height) for the replicate analysis (n=5) of 0.5mugl(-1) solution were 3 and 5% for As(III) and As(V), respectively. The limit of detection (3sigma) for both As(III) and As(V) were 0.1mugl(-1). The proposed system produced satisfactory results on the application to the direct analysis of inorganic arsenic species in freshwater samples.

Entities:  

Year:  2005        PMID: 18970017     DOI: 10.1016/j.talanta.2004.09.024

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Method optimization for heavy metal determination in milk powder: application to milk samples from Greece.

Authors:  Emmanouil Evgenakis; Christophoros Christophoridis; Konstantinos Fytianos
Journal:  Environ Sci Pollut Res Int       Date:  2017-09-05       Impact factor: 4.223

2.  A simple and cost-effective paper-based and colorimetric dual-mode detection of arsenic(iii) and lead(ii) based on glucose-functionalized gold nanoparticles.

Authors:  Bhuneshwari Sahu; Ramsingh Kurrey; Manas Kanti Deb; Kamlesh Shrivas; Indrapal Karbhal; Beeta Rani Khalkho
Journal:  RSC Adv       Date:  2021-06-10       Impact factor: 4.036

3.  Titanium dioxide solid phase for inorganic species adsorption and determination: the case of arsenic.

Authors:  R Vera; C Fontàs; E Anticó
Journal:  Environ Sci Pollut Res Int       Date:  2016-09-21       Impact factor: 4.223

4.  Immobilization of acetylcholinesterase on screen-printed electrodes. Application to the determination of arsenic(III).

Authors:  Silvia Sanllorente-Méndez; Olga Domínguez-Renedo; M Julia Arcos-Martínez
Journal:  Sensors (Basel)       Date:  2010-03-16       Impact factor: 3.576

Review 5.  Aggregation Induced Emissive Luminogens for Sensing of Toxic Elements.

Authors:  Geeta A Zalmi; Vilas K Gawade; Dinesh N Nadimetla; Sheshanath V Bhosale
Journal:  ChemistryOpen       Date:  2021-07       Impact factor: 2.630

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.