Literature DB >> 18969466

Preconcentrative separation of chromium(VI) species from chromium(III) by coprecipitation of its ethyl xanthate complex onto naphthalene.

P Gopi Krishna1, J Mary Gladis, U Rambabu, T Prasada Rao, G R K Naidu.   

Abstract

A rapid, sensitive and selective method is described for the determination of chromium(VI) in presence of 100-fold amounts of chromium(III) by flame atomic absorption spectrometry (FAAS) in conjunction with coprecipitative preconcentration of its ethyl xanthate complex onto naphthalene. The solid mixture consisting of the chromium(VI) complex together with naphthalene is dissolved in 8.0ml of dimethyl formamide (DMF) and chromium(VI) content was established by FAAS. Calibration graphs were rectilinear over the chromium(VI) concentration in the range 0-200mugl(-1). Five replicate determinations of 20mug of chromium(VI) present in 1.0l of sample solution gave a relative standard deviation of 3.1%. The detection limit corresponding to three times the standard deviation of the blank was found to be 0.5mugl(-1). The developed procedure has been successfully utilized for the estimation of chromium(VI), chromium(total) (after oxidation with bromate) and chromium(III) (by subtracting chromium(VI) content from chromium(total) value contents of several tannery industries.

Entities:  

Year:  2004        PMID: 18969466     DOI: 10.1016/j.talanta.2003.11.032

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Preconcentration and speciation of Cr(III) and Cr(VI) in water and soil samples by spectrometric detection via use of nanosized alumina-coated magnetite solid phase.

Authors:  Hossein Tavallali; Gohar Deilamy-Rad; Pegah Peykarimah
Journal:  Environ Monit Assess       Date:  2013-02-21       Impact factor: 2.513

2.  Monitoring of trace amounts of heavy metals in different food and water samples by flame atomic absorption spectrophotometer after preconcentration by amine-functionalized graphene nanosheet.

Authors:  Mohammad Behbahani; Nasim Akbari Ghareh Tapeh; Mojtaba Mahyari; Ali Reza Pourali; Bahareh Golrokh Amin; Ahmad Shaabani
Journal:  Environ Monit Assess       Date:  2014-07-15       Impact factor: 2.513

3.  Application of pneumatic flow injection-tandem spectrometer system for chromium speciation.

Authors:  Meissam Noroozifar; Mozhgan Khorasani-Motlagh; Reza Akbari
Journal:  J Autom Methods Manag Chem       Date:  2007

4.  Ultratrace Determination of Cr(VI) and Pb(II) by Microsample Injection System Flame Atomic Spectroscopy in Drinking Water and Treated and Untreated Industrial Effluents.

Authors:  Jameel Ahmed Baig; Tasneem Gul Kazi; Latif Elci; Hassan Imran Afridi; Muhammad Irfan Khan; Hafiz Muhammad Naseer
Journal:  J Anal Methods Chem       Date:  2013-09-18       Impact factor: 2.193

5.  Self-assembly modified-mushroom nanocomposite for rapid removal of hexavalent chromium from aqueous solution with bubbling fluidized bed.

Authors:  Fei Xu; Xu Liu; Yijiao Chen; Ke Zhang; Heng Xu
Journal:  Sci Rep       Date:  2016-05-18       Impact factor: 4.379

  5 in total