Literature DB >> 18969273

Hydrogen ion-selective poly(vinyl chloride) membrane electrode based on a p-tert-butylcalix[4]arene-oxacrown-4.

Ayça Demirel1, Alev Doğan, Esin Canel, Shahabuddin Memon, Mustafa Yilmaz, Esma Kilic .   

Abstract

A hydrogen ion-selective poly(vinyl chloride) (PVC) membrane electrode was developed using p-tert-butylcalix[4]arene-oxacrown-4 as ionophore. Apart from the ionophore, plasticisers and lipophilic anions were blended, in various proportions, with PVC in tetrahydrofurane and mixtures so prepared were poured onto glass surfaces to form the membrane. 2-Nitrophenylpentylether has proved to be the best alternative as plasticiser and the lipophilic anions tried have turned out to have an adverse effect on the pH response. The electrode of the optimum characteristics had a composition of 2% p-tert-butylcalix[4]arene-oxacrown-4, 68.3% o-NPPE and 29.7% PVC. The electrode showed an apparent Nernstian response in the pH range 2-11 with a slope of 54.2+/-0.4mVpH(-1) at 20+/-1 degrees C. It has a rapid potential-response to changes of pH, high ion selectivity towards lithium, sodium and potassium, and other characteristics comparable to those reported for the conventional pH glass membrane electrode. It appears to be a suitable potentiometric indicator electrode specifically for hydrofluoric acid solutions.

Entities:  

Year:  2004        PMID: 18969273     DOI: 10.1016/S0039-9140(03)00414-4

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Syntheses and pH sensing applications of imine-coupled phenol and polyphenol species derived from 2-amino-4-nitrophenol.

Authors:  Mehmet Yıldırım; Aysel Aydın; Ismet Kaya
Journal:  J Fluoresc       Date:  2012-01-07       Impact factor: 2.217

2.  Synthesis and Characterization of Organic-Inorganic Nanocomposite Poly-o-anisidine Sn(IV) Arsenophosphate: Its Analytical Applications as Pb(II) Ion-Selective Membrane Electrode.

Authors:  Asif Ali Khan; Umme Habiba; Anish Khan
Journal:  Int J Anal Chem       Date:  2009-08-09       Impact factor: 1.885

3.  Design and Characterization of Electrochemical Sensor for the Determination of Mercury(II) Ion in Real Samples Based upon a New Schiff Base Derivative as an Ionophore.

Authors:  Salman S Alharthi; Ahmed M Fallatah; Hamed M Al-Saidi
Journal:  Sensors (Basel)       Date:  2021-04-25       Impact factor: 3.576

Review 4.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade.

Authors:  Farnoush Faridbod; Parviz Norouzi; Rassoul Dinarvand; Mohammad Reza Ganjali
Journal:  Sensors (Basel)       Date:  2008-04-03       Impact factor: 3.576

5.  Synthesis of silver embedded poly(o-anisidine) molybdophosphate nano hybrid cation-exchanger applicable for membrane electrode.

Authors:  Anish Khan; Aftab Aslam Parwaz Khan; Abdullah M Asiri; Malik Abdul Rub
Journal:  PLoS One       Date:  2014-05-07       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.