Literature DB >> 33923078

Design and Characterization of Electrochemical Sensor for the Determination of Mercury(II) Ion in Real Samples Based upon a New Schiff Base Derivative as an Ionophore.

Salman S Alharthi1, Ahmed M Fallatah1, Hamed M Al-Saidi2.   

Abstract

The present paper provides a description of the design, characterization, and use of a Hg2+ selective electrode (Hg2+-SE) for the determination of Hg2+ at ultra-traces levels in a variety of real samples. The ionophore in the proposed electrode is a new Schiff base, namely 4-bromo-2-[(4-methoxyphenylimino)methyl]phenol (BMPMP). All factors affecting electrode response including polymeric membrane composition, concentration of internal solution, pH sample solution, and response time were optimized. The optimum response of our electrode was obtained with the following polymeric membrane composition (% w/w): PVC, 32; o-NPOE, 64.5; BMPMP, 2 and NaTPB, 1.5. The potentiometric response of Hg2+-SE towards Hg2+ ion was linear in the wide range of concentrations (9.33 × 10-8-3.98 × 10-3 molL-1), while, the limit of detection of the proposed electrode was 3.98 × 10-8 molL-1 (8.00 μg L-1). The Hg2+-SE responds quickly to Hg2+ ions as the response time of less than 10 s. On the other hand, the slope value obtained for the developed electrode was 29.74 ± 0.1 mV/decade in the pH range of 2.0-9.0 in good agreement with the Nernstian response (29.50 mV/decade). The Hg2+-SE has relatively less interference with other metal ions. The Hg2+-SE was used as an indicator electrode in potentiometric titrations to estimate Hg2+ ions in waters, compact fluorescent lamp, and dental amalgam alloy and the accuracy of the developed electrode was compared with ICP-OES measurement values. Moreover, the new Schiff base (BMPMP) was synthesized and characterized using ATR-FTIR, elemental analysis, 1H NMR, and 13C NMR. The PVC membranes containing BMPMP as an ionophore unloaded and loaded with Hg(II) are reported by scanning electron microscope images (SEM) along with energy-dispersive X-ray spectroscopy (EDX) spectra.

Entities:  

Keywords:  ISE-Hg; PVC membrane; Schiff base; ionophore; mercury selective electrode

Year:  2021        PMID: 33923078     DOI: 10.3390/s21093020

Source DB:  PubMed          Journal:  Sensors (Basel)        ISSN: 1424-8220            Impact factor:   3.576


  30 in total

1.  Determination of mercury in fish by cold vapor atomic absorption spectrophotometry using a multicommuted flow injection analysis system.

Authors:  M Fátima Silva; Ildikó V Tóth; António O S S Rangel
Journal:  Anal Sci       Date:  2006-06       Impact factor: 2.081

2.  Determination of mercury in whole blood and urine by inductively coupled plasma mass spectrometry.

Authors:  Bonnie Mei Wah Fong; Tak Shing Siu; Joseph Sai Kit Lee; Sidney Tam
Journal:  J Anal Toxicol       Date:  2007-06       Impact factor: 3.367

3.  A highly selective mercury electrode based on a diamine donor ligand.

Authors:  Vinod K Gupta; Sudeshna Chandra; Heinrich Lang
Journal:  Talanta       Date:  2005-01-18       Impact factor: 6.057

4.  Solid-contact Hg(II)-selective electrode based on a carbon-epoxy composite containing a new dithiophosphate-based ionophore.

Authors:  J Juarez-Gomez; F Perez-Garcia; M T Ramirez-Silva; A Rojas-Hernandez; C A Galan-Vidal; M E Paez-Hernandez
Journal:  Talanta       Date:  2013-05-16       Impact factor: 6.057

5.  Part 1. Spectrophotometric determination of trace mercury (II) in dental-unit wastewater and fertilizer samples using the novel reagent 6-hydroxy-3-(2-oxoindolin-3-ylideneamino)-2-thioxo-2H-1,3-thiazin-4(3H)-one and the dual-wavelength beta-correction spectrophotometry.

Authors:  A Hamza; A S Bashammakh; A A Al-Sibaai; H M Al-Saidi; M S El-Shahawi
Journal:  J Hazard Mater       Date:  2010-01-21       Impact factor: 10.588

6.  Simultaneous trace-levels determination of Hg(II) and Pb(II) ions in various samples using a modified carbon paste electrode based on multi-walled carbon nanotubes and a new synthesized Schiff base.

Authors:  Abbas Afkhami; Hasan Bagheri; Hosein Khoshsafar; Mohammad Saber-Tehrani; Masoumeh Tabatabaee; Ali Shirzadmehr
Journal:  Anal Chim Acta       Date:  2012-08-23       Impact factor: 6.558

Review 7.  Electrochemical sensing of heavy metal ions with inorganic, organic and bio-materials.

Authors:  Lin Cui; Jie Wu; Huangxian Ju
Journal:  Biosens Bioelectron       Date:  2014-07-28       Impact factor: 10.618

8.  Potentiometric sensing utilizing paper-based microfluidic sampling.

Authors:  Jingwen Cui; Grzegorz Lisak; Sylwia Strzalkowska; Johan Bobacka
Journal:  Analyst       Date:  2014-05-07       Impact factor: 4.616

9.  A new electrochemical sensor based on task-specific ionic liquids-modified palm shell activated carbon for the determination of mercury in water samples.

Authors:  Ahmed Abu Ismaiel; Mohamed Kheireddine Aroua; Rozita Yusoff
Journal:  Sensors (Basel)       Date:  2014-07-21       Impact factor: 3.576

10.  Determination of total mercury in seafood by ion-selective electrodes based on a thiol functionalized ionic liquid.

Authors:  Juan Miao; Xin Wang; Yunchang Fan; Jing Li; Lina Zhang; Guitao Hu; Can He; Can Jin
Journal:  J Food Drug Anal       Date:  2017-09-22       Impact factor: 6.157

View more
  2 in total

1.  Rapid electrochemical sensor for uranium(vi) assessment in aqueous media.

Authors:  Zeinab F Akl
Journal:  RSC Adv       Date:  2022-07-11       Impact factor: 4.036

2.  Dual-Emission Fluorescence Probe Based on CdTe Quantum Dots and Rhodamine B for Visual Detection of Mercury and Its Logic Gate Behavior.

Authors:  Yuefeng Gao; Sai Xu; Zhijian Liu; Kezhen Yu; Xinxiang Pan
Journal:  Micromachines (Basel)       Date:  2021-06-18       Impact factor: 2.891

  2 in total