Literature DB >> 18969027

Mercury(II) ion-selective polymeric membrane sensor based on a recently synthesized Schiff base.

Mohammad Hossein Mashhadizadeh1, Iran Sheikhshoaie.   

Abstract

A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Hg(II) ions was prepared by using bis[5-((4-nitrophenyl)azo salicylaldehyde)] (BNAS) as a suitable neutral carrier. The sensor exhibits a Nernstian response for mercury ions over a wide concentration range (5.0x10(-2)-7.0x10(-7) M) with a slope of 30+/-1 mV per decade. It has a response time of <10 s and can be used for at least 3 months without any measurable divergence in potential. The electrode can be used in the pH range from 1.0 to 3.5. The proposed sensor shows fairly good discriminating ability towards Hg(2+) ion in comparison with some hard and soft metals. The electrode was used in the direct determination of Hg(2+) in aqueous solution and as an indicator electrode in potentiometric titration of mercury ions.

Entities:  

Year:  2003        PMID: 18969027     DOI: 10.1016/S0039-9140(03)00036-5

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  Design and Characterization of Electrochemical Sensor for the Determination of Mercury(II) Ion in Real Samples Based upon a New Schiff Base Derivative as an Ionophore.

Authors:  Salman S Alharthi; Ahmed M Fallatah; Hamed M Al-Saidi
Journal:  Sensors (Basel)       Date:  2021-04-25       Impact factor: 3.576

Review 2.  Developments in the Field of Conducting and Non-conducting Polymer Based Potentiometric Membrane Sensors for Ions Over the Past Decade.

Authors:  Farnoush Faridbod; Parviz Norouzi; Rassoul Dinarvand; Mohammad Reza Ganjali
Journal:  Sensors (Basel)       Date:  2008-04-03       Impact factor: 3.576

3.  Schiff's Bases and Crown Ethers as Supramolecular Sensing Materials in the Construction of Potentiometric Membrane Sensors.

Authors:  Farnoush Faridbod; Mohammad Reza Ganjali; Rassoul Dinarvand; Parviz Norouzi; Siavash Riahi
Journal:  Sensors (Basel)       Date:  2008-03-11       Impact factor: 3.576

4.  Flow injection analysis of mercury using 4-(dimethylamino) benzaldehyde-4-ethylthiosemicarbazone as the ionophore of a coated wire electrode.

Authors:  Tara F Tahir; Abdussalam Salhin; Sulaiman Ab Ghani
Journal:  Sensors (Basel)       Date:  2012-11-06       Impact factor: 3.576

5.  A new electrochemical sensor based on task-specific ionic liquids-modified palm shell activated carbon for the determination of mercury in water samples.

Authors:  Ahmed Abu Ismaiel; Mohamed Kheireddine Aroua; Rozita Yusoff
Journal:  Sensors (Basel)       Date:  2014-07-21       Impact factor: 3.576

6.  2,6-Bis((benzoyl-R)amino)pyridine (R = H, 4-Me, and 4-NMe2) Derivatives for the Removal of Cu(II), Ni(II), Co(II), and Zn(II) Ions from Aqueous Solutions in Classic Solvent Extraction and a Membrane Extraction.

Authors:  Daria Bożejewicz; Borys Ośmiałowski; Małgorzata Anna Kaczorowska; Katarzyna Witt
Journal:  Membranes (Basel)       Date:  2021-03-25
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.