Literature DB >> 18968370

Determination of chromium(VI) and lead(II) in drinking water by electrokinetic flow analysis system and graphite furnace atomic absorption spectrometry.

L Yang1, Y Z He, W E Gan, M Li, Q S Qu, X Q Lin.   

Abstract

An electrokinetic flow analysis system (EKFA) using an electroosmotic pump (Peo) and a bi-directional electrostacking (BDES) unit is introduced in this paper. Large flow range, moderate carrier pressure, low performance voltage and stable flow rate, especially in mulmin(-1) level, are the main specialties of the Peo. Diethanolamine, 0.5 mM, is selected as its carrier to improve the pump efficiency and stability further. Moreover, BDES, a feasibility investigation for the simultaneous separation and pre-concentration of cations and anions, and graphite furnace atomic absorption spectrometry (GFAAS) determination are presented. The calibration series for both of Cr(VI) and Pb(II) are from 0.2 to 40 mugl(-1) with 10 mul pipette volume and GFAAS determination directly. The detection limit of Cr(VI) and Pb(II) with 10 min BDES is 10 and 13 ngl(-1)(3sigma of blank, n=11), respectively. The recovery of Cr(VI) and Pb(II) is (103-105)+/-1% and (95.9-96.9)+/-1.0% with three independent determinations, respectively. The investigated method is also suitable for the simultaneous separation and pre-concentration of trace cations and anions in low conductivity sample solutions with different detection instruments.

Entities:  

Year:  2001        PMID: 18968370     DOI: 10.1016/s0039-9140(01)00424-6

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Electroosmotic pumps and their applications in microfluidic systems.

Authors:  Xiayan Wang; Chang Cheng; Shili Wang; Shaorong Liu
Journal:  Microfluid Nanofluidics       Date:  2009-02-01       Impact factor: 2.529

2.  Electroosmotic pumps for microflow analysis.

Authors:  Xiayan Wang; Shili Wang; Brina Gendhar; Chang Cheng; Chang Kyu Byun; Guanbin Li; Meiping Zhao; Shaorong Liu
Journal:  Trends Analyt Chem       Date:  2009       Impact factor: 12.296

3.  On-line micro column preconcentration system based on amino bimodal mesoporous silica nanoparticles as a novel adsorbent for removal and speciation of chromium (III, VI) in environmental samples.

Authors:  Hamid Shirkhanloo; Aisan Khaligh; Farideh Golbabaei; Zargham Sadeghi; Amir Vahid; Alimorad Rashidi
Journal:  J Environ Health Sci Eng       Date:  2015-05-22
  3 in total