Literature DB >> 18968332

Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip.

G Cui1, J H Yoo, B W Woo, S S Kim, G S Cha, H Nam.   

Abstract

Electrochemical properties of screen-printed carbon paste electrodes (CPEs) with a glucose oxidase-immobilized and hexamineruthenium (III) chloride ([Ru(NH(3))(6)](3+)) containing nitrocellulose (NC) strip were examined. The NC strip (2x8 mm) placed on the CPEs printed on polyester (PE) film is tightly sealed using another PE film on the top with open edges on both sides. Samples containing macromolecules and particles (e.g. proteins and blood cells) are applied at one edge of the NC strip and reach the detection area, chromatographically separating small molecules (e.g. glucose, ascorbate, acetaminophen, and uric acid) of analytical interests. Since sample volumes and the amount of catalytic reagents (mediator and glucose oxidase) are precisely predefined by the dimension and pore size (8 mum) of the NC strip, the sensor-to-sensor reproducibility and accuracy of analysis are greatly improved. The use of [Ru(NH(3))(6)](3+) mediator, which exhibits characteristic substantially lowers the applied potential (0.0 V vs Ag/AgCl) for glucose determination and eliminates the interference from other oxidizable species, providing improved analytical results.

Entities:  

Year:  2001        PMID: 18968332     DOI: 10.1016/s0039-9140(01)00377-0

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  6 in total

1.  A stretchable and screen-printed electrochemical sensor for glucose determination in human perspiration.

Authors:  A Abellán-Llobregat; Itthipon Jeerapan; A Bandodkar; L Vidal; A Canals; J Wang; E Morallón
Journal:  Biosens Bioelectron       Date:  2017-01-26       Impact factor: 10.618

Review 2.  Advanced wearable biosensors for the detection of body fluids and exhaled breath by graphene.

Authors:  Santoshi U Singh; Subhodeep Chatterjee; Shahbaz Ahmad Lone; Hsin-Hsuan Ho; Kuldeep Kaswan; Kiran Peringeth; Arshad Khan; Yun-Wei Chiang; Sangmin Lee; Zong-Hong Lin
Journal:  Mikrochim Acta       Date:  2022-05-28       Impact factor: 6.408

3.  A potentiometric indirect uric acid sensor based on ZnO nanoflakes and immobilized uricase.

Authors:  Syed M Usman Ali; Zafar Hussain Ibupoto; Muhammad Kashif; Uda Hashim; Magnus Willander
Journal:  Sensors (Basel)       Date:  2012-03-01       Impact factor: 3.576

4.  Synthesis of Heart/Dumbbell-Like CuO Functional Nanostructures for the Development of Uric Acid Biosensor.

Authors:  Zafar Hussain Ibupoto; Aneela Tahira; Hamid Raza; Gulzar Ali; Aftab Ahmed Khand; Nabila Shah Jilani; Arfana Begum Mallah; Cong Yu; Magnus Willander
Journal:  Materials (Basel)       Date:  2018-08-08       Impact factor: 3.623

Review 5.  Paper-Based Enzymatic Electrochemical Sensors for Glucose Determination.

Authors:  Olaya Amor-Gutiérrez; Estefanía Costa-Rama; M Teresa Fernández-Abedul
Journal:  Sensors (Basel)       Date:  2022-08-19       Impact factor: 3.847

6.  A Disposable paper breathalyzer with an alcohol sensing organic electrochemical transistor.

Authors:  Eloїse Bihar; Yingxin Deng; Takeo Miyake; Mohamed Saadaoui; George G Malliaras; Marco Rolandi
Journal:  Sci Rep       Date:  2016-06-13       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.