Literature DB >> 18958570

Intraoperative colonoscopy for stapled anastomosis in colorectal surgery.

Soichiro Ishihara1, Toshiaki Watanabe, Hirokazu Nagawa.   

Abstract

Although stapling colorectal anastomosis is widely accepted as an alternative for hand-sewn anastomosis, we continue to experience postoperative complications such as anastomotic hemorrhage and leakage, which sometimes lead to serious morbidity or even mortality. To secure stapling colorectal anastomosis, we adopted intraoperative colonoscopy (IOCS). We performed IOCS in 73 cases of colorectal resection with stapling anastomosis from November 2004 to October 2005. Intraoperative colonoscopy revealed active bleeding from stapling anastomosis in 7 patients (9.6%). Of these, additional sutures were done in 6 patients, while the anastomosis was exteriorized in the other. The air leak test performed by IOCS was positive in 4 patients (5.5%), with additional sutures being done in 2 patients and reanastomoses performed in the other 2. Incomplete cutting of the mucosa was found in one patient, but it was successfully managed. Following the introduction of IOCS, there were no cases of postoperative anastomotic hemorrhage, and only one case of anastomotic leakage (1.4%).

Entities:  

Mesh:

Year:  2008        PMID: 18958570     DOI: 10.1007/s00595-007-3740-0

Source DB:  PubMed          Journal:  Surg Today        ISSN: 0941-1291            Impact factor:   2.549


  6 in total

1.  Use of a mechanical suturing apparatus in low colorectal anastomosis.

Authors:  S N Fain; C S Patin; L Morgenstern
Journal:  Arch Surg       Date:  1975-09

Review 2.  Stapled versus handsewn methods for colorectal anastomosis surgery.

Authors:  S A Lustosa; D Matos; A N Atallah; A A Castro
Journal:  Cochrane Database Syst Rev       Date:  2001

3.  Curative resection performed twice for circular-staple-line recurrence after colorectal carcinoma surgery: report of a case.

Authors:  Kazuhito Yajima; Hitoshi Matsuo; Takashi Kobayashi; Yoichi Ajioka; Katsuyoshi Hatakeyama
Journal:  Surg Today       Date:  2007-01-01       Impact factor: 2.549

4.  Use of the circular stapler in 1000 consecutive colorectal anastomoses: experience of one surgical team.

Authors:  R J Detry; A Kartheuser; L Delriviere; J Saba; P J Kestens
Journal:  Surgery       Date:  1995-02       Impact factor: 3.982

Review 5.  Endoscopic treatment of postoperative hemorrhage from a stapled colorectal anastomosis.

Authors:  W C Cirocco; R W Golub
Journal:  Am Surg       Date:  1995-05       Impact factor: 0.688

6.  Infraperitoneal colorectal anastomosis: hand-sewn versus circular staples. A controlled clinical trial. French Associations for Surgical Research.

Authors:  A Fingerhut; A Elhadad; J M Hay; F Lacaine; Y Flamant
Journal:  Surgery       Date:  1994-09       Impact factor: 3.982

  6 in total
  16 in total

1.  Endoscopic intraoperative anastomotic testing may avoid early gastrointestinal anastomotic complications. A prospective study.

Authors:  Eva Lieto; Michele Orditura; Paolo Castellano; Margherita Pinto; Anna Zamboli; Ferdinando De Vita; Carlo Pignatelli; Gennaro Galizia
Journal:  J Gastrointest Surg       Date:  2011-01       Impact factor: 3.452

2.  SAGES evidence-based guidelines for the laparoscopic resection of curable colon and rectal cancer.

Authors:  Marc Zerey; Lisa Martin Hawver; Ziad Awad; Dimitrios Stefanidis; William Richardson; Robert D Fanelli
Journal:  Surg Endosc       Date:  2012-12-13       Impact factor: 4.584

Review 3.  Prediction and diagnosis of colorectal anastomotic leakage: A systematic review of literature.

Authors:  Freek Daams; Zhouqiao Wu; Max Jef Lahaye; Johannus Jeekel; Johan Frederik Lange
Journal:  World J Gastrointest Surg       Date:  2014-02-27

4.  Use of a transanal drainage tube for prevention of anastomotic leakage and bleeding after anterior resection for rectal cancer.

Authors:  Wen-Tao Zhao; Feng-Liang Hu; Yu-Ying Li; Hong-Jie Li; Wei-Ming Luo; Feng Sun
Journal:  World J Surg       Date:  2013-01       Impact factor: 3.352

5.  The short-term outcomes of robotic sphincter-preserving surgery for rectal cancer: comparison with open and laparoscopic surgery using a propensity score analysis.

Authors:  Soichiro Ishihara; Tomomichi Kiyomatsu; Kazushige Kawai; Toshiaki Tanaka; Keisuke Hata; Shinsuke Kazama; Eiji Sunami; Hiroaki Nozawa; Toshiaki Watanabe
Journal:  Int J Colorectal Dis       Date:  2018-04-23       Impact factor: 2.571

Review 6.  Intraoperative assessment of colorectal anastomotic integrity: a systematic review.

Authors:  Subramanian Nachiappan; Alan Askari; Andrew Currie; Robin H Kennedy; Omar Faiz
Journal:  Surg Endosc       Date:  2014-04-10       Impact factor: 4.584

Review 7.  Anastomotic Failure in Colorectal Surgery: Where Are We at?

Authors:  Vinna An; Raaj Chandra; Matthew Lawrence
Journal:  Indian J Surg       Date:  2018-03-03       Impact factor: 0.656

8.  Safety and factors contributing to the difficulty of laparoscopic surgery for rectal cancer treated with preoperative chemoradiotherapy.

Authors:  S Ishihara; T Watanabe; Y Fukushima; T Akahane; A Horiuchi; R Shimada; K Nakamura; T Hayama; H Yamada; K Nozawa; K Matsuda; Y Hashiguchi
Journal:  Tech Coloproctol       Date:  2013-09-17       Impact factor: 3.781

9.  Laparoscopic vs. open surgery for T4 colon cancer: A propensity score analysis.

Authors:  Nicola de'Angelis; Giulio Cesare Vitali; Francesco Brunetti; Charles-Henri Wassmer; Charlotte Gagniere; Giacomo Puppa; Christophe Tournigand; Frédéric Ris
Journal:  Int J Colorectal Dis       Date:  2016-09-14       Impact factor: 2.571

10.  Experimental Study of Mechanical Integrity Testing in Stapled Large Bowel: Methylene Blue Leak Test Is Not Inferior to Air Leak Test.

Authors:  Marius Kryzauskas; Austeja Elzbieta Degutyte; Vilius Abeciunas; Beatrice Lukenaite; Eugenijus Jasiunas; Eligijus Poskus; Kestutis Strupas; Tomas Poskus
Journal:  Visc Med       Date:  2020-10-12
View more