Literature DB >> 18949299

Influence of cervical preflaring on determination of apical file size in mandibular molars: SEM analysis.

Marcia da Silva Schmitz1, Roberto Santos, Alexandre Capelli, Marcos Jacobovitz, Júlio César Emboava Spanó, Jesus Djalma Pécora.   

Abstract

This study investigated the influence of cervical preflaring with different rotary instruments on determination of the initial apical file (IAF) in mesiobuccal roots of mandibular molars. Fifty human mandibular molars whose mesial roots presented two clearly separated apical foramens (mesiobuccal and mesiolingual) were used. After standard access opening and removal of pulp tissue, the working length (WL) was determined at 1 mm short of the root apex. Five groups (n=10) were formed at random, according to the type of instrument used for cervical preflaring. In group 1, the size of the IAF was determined without preflaring of the cervical and middle root canal thirds. In groups 2 to 5, preflaring was performed with Gates-Glidden drills, ProTaper instruments, EndoFlare instruments and LA Axxes burs, respectively. Canals were sized manually with K-files, starting with size 08 K-files, inserted passively up to the WL. File sizes were increased until a binding sensation was felt at the WL and the size of the file was recorded. The instrument corresponding to the IAF was fixed into the canal at the WL with methylcyanoacrylate. The teeth were then sectioned transversally 1 mm short of the apex, with the IAF in position. Cross-sections of the WL region were examined under scanning electron microscopy and the discrepancies between canal diameter and the diameter of IAF were calculated using the tool "rule" (FEG) of the microscope's proprietary software. The measurements (microm) were analyzed statistically by Kruskal-Wallis and Dunn's tests at 5% significance level. There were statistically significant differences among the groups (p<0.05). The non-flared group had the greatest discrepancy (125.30 +/- 51.54) and differed significantly from all flared groups (p<0.05). Cervical preflaring with LA Axxess burs produced the least discrepancies (55.10 +/- 48.31), followed by EndoFlare instruments (68.20 +/- 42.44), Gattes Glidden drills (68.90 +/- 42.46) and ProTaper files (77.40 +/- 73.19). However, no significant differences (p>0.05) were found among the rotary instruments. In conclusion, cervical preflaring improved IAF fitting to the canals at the WL in mesiobuccal roots of maxillary first molars. The rotary instruments evaluated in this study did not differ from each other regarding the discrepancies produced between the IAF size and canal diameter at the WL.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18949299     DOI: 10.1590/s0103-64402008000300013

Source DB:  PubMed          Journal:  Braz Dent J        ISSN: 0103-6440


  4 in total

1.  Accuracy of five electronic foramen locators with different operating systems: an ex vivo study.

Authors:  Bruno Carvalho de Vasconcelos; Michelli de Medeiros Bueno; Suyane Maria Luna-Cruz; Marco Antonio Hungaro Duarte; Carlos Augusto de Oliveira Fernandes
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

2.  The minimum residual root thickness after using ProTaper, RaCe and Gates-Glidden drills: A cone beam computerized tomography study.

Authors:  Nahid Mohammadzadeh Akhlaghi; Laleh Mohammadian Bajgiran; Amirali Naghdi; Elaheh Behrooz; Zohreh Khalilak
Journal:  Eur J Dent       Date:  2015 Apr-Jun

3.  The Effect of Gates-Glidden Drills on the Quality of Root Canal Treatment by Pre-Clinical Dental Students.

Authors:  Roohollah Sharifi; Amin Torabi; Reza Hatam; Nafiseh Nikkerdar; Hamid Reza Mozaffari; Mohsen Safaei; Seyed Mojtaba Amiri
Journal:  Open Access Maced J Med Sci       Date:  2018-11-23

4.  Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments.

Authors:  Theodoro Weissheimer; Murilo Alcalde; Julia Barrionuevo Cortez; Ricardo Rosa; Rodrigo Vivan; Pedro Henrique Souza Calefi; Marco Antonio Hungaro Duarte; Marcus Vinicius So
Journal:  Eur Endod J       Date:  2021-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.