Literature DB >> 1894869

Intravascular ultrasound imaging of angiographically normal coronary arteries: an in vivo comparison with quantitative angiography.

F G St Goar1, F J Pinto, E L Alderman, P J Fitzgerald, M L Stadius, R L Popp.   

Abstract

Intravascular ultrasound, a new technique for real-time two-dimensional visualization of arteries and veins, delineates vessel wall morphology and measures luminal dimensions. This imaging method has been validated with in vitro systems and in peripheral vessels, but there are few in vivo coronary artery studies. Twenty cardiac transplant recipients with no angiographic coronary artery disease were scanned with a 30-MHz intravascular ultrasound catheter from the left main coronary ostium to the mid-left anterior descending coronary artery. Simultaneous angiographic measurements were performed at 76 sites. Ultrasound end-diastolic diameters in two perpendicular axes were 3.8 +/- 0.9 and 3.9 +/- 0.6 mm, respectively, and mean diameter derived from an area determined by planimetry was 3.9 +/- 0.9 mm. Angiographic coronary artery diameters measured with a computer-assisted edge detection system perpendicular to the long axis of the vessel and to the long axis of the catheter were 3.4 +/- 0.8 and 3.6 +/- 0.8 mm, respectively. Luminal diameters measured with the two imaging systems correlated closely, with an r value of 0.86 when ultrasound was compared with the angiographic diameter measured perpendicular to the vessel and 0.88 when compared with the angiographic diameter measured perpendicular to the imaging catheter. Eighty-three percent of the ultrasound-measured diameters were above the line of identity when compared with the simultaneous angiographic measurement. The more the imaging catheter deviated from the long axis of the vessel, the greater was the discrepancy between the ultrasound and angiographic measurements.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1894869     DOI: 10.1016/0735-1097(91)90753-v

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  13 in total

1.  Influence of coronary pulsation on volumetric intravascular ultrasound measurements performed without ECG-gating. Validation in vessel segments with minimal disease.

Authors:  Hiroshi Tsutsui; Paul Schoenhagen; Timothy D Crowe; Jon D Klingensmith; D Geoffrey Vince; Steven E Nissen; E Murat Tuzcu
Journal:  Int J Cardiovasc Imaging       Date:  2003-02       Impact factor: 2.357

2.  Comparison of QCA systems.

Authors:  U Dietz; H J Rupprecht; R Brennecke; H P Fritsch; J Woltmann; S Blankenberg; J Meyer
Journal:  Int J Card Imaging       Date:  1997-08

3.  Intravascular Ultrasound Versus Optical Coherence Tomography for Coronary Artery Imaging - Apples and Oranges?

Authors:  Krishnaraj S Rathod; Stephen M Hamshere; Daniel A Jones; Anthony Mathur
Journal:  Interv Cardiol       Date:  2015-03

4.  Use of Intravascular Ultrasound Imaging in Percutaneous Coronary Intervention to Treat Left Main Coronary Artery Disease.

Authors:  Giovanni Luigi De Maria; Adrian P Banning
Journal:  Interv Cardiol       Date:  2017-05

5.  Wall composition in intravascular ultrasound layered appearance of human coronary artery.

Authors:  S Kawano; M Yamagishi; H Hao; C Yutani; K Miyatake
Journal:  Heart Vessels       Date:  1996       Impact factor: 2.037

Review 6.  Intracoronary ultrasound: current state of the art.

Authors:  P P Kearney; I R Starkey; G R Sutherland
Journal:  Br Heart J       Date:  1995-05

7.  Progression of cardiac allograft vascular disease as assessed by serial intravascular ultrasound: correlation to immunological and non-immunological risk factors.

Authors:  K Pethig; V Klauss; B Heublein; H Mudra; A Westphal; C Weber; K Theisen; A Haverich
Journal:  Heart       Date:  2000-11       Impact factor: 5.994

8.  Use of intravascular ultrasound for in vivo assessment of changes in intimal thickness of angiographically normal saphenous vein grafts one year after aortocoronary bypass surgery.

Authors:  T Hozumi; J Yoshikawa; K Yoshida; T Akasaka; T Takagi; Y Honda; H Okura
Journal:  Heart       Date:  1996-10       Impact factor: 5.994

9.  Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation.

Authors:  Michael T Tomkowiak; Amish N Raval; Michael S Van Lysel; Tobias Funk; Michael A Speidel
Journal:  J Med Imaging (Bellingham)       Date:  2014-10

10.  Variable coronary vasomotor responses to acetylcholine in patients with normal coronary arteriograms: evidence for localised endothelial dysfunction.

Authors:  D Tousoulis; G Davies; D C Lefroy; A W Haider; T Crake
Journal:  Heart       Date:  1996-03       Impact factor: 5.994

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.