Comparison of catheter ablation using radiofrequency versus direct current energy: biophysical, electrophysiologic and pathologic observations.

S K Huang1, A R Graham, M A Lee, M E Ring, G D Gorman, R Schiffman.   

Abstract

The effects of catheter ablation with radiofrequency versus direct current energy were compared in 18 dogs assigned to two groups (of 9 dogs each). Each dog underwent a single ablation at two sites in the left ventricle at energy levels of 100, 200 or 300 J delivered in unipolar configuration to six dogs each. A transient decrease in left ventricular systolic pressure (from 121.3 +/- 24.5 to 94.2 +/- 18.7 mm Hg, p less than 0.01) and wall motion abnormality were noted in dogs with direct current shock. The left ventricular ejection fraction decreased (from 50 +/- 2% to 34 +/- 3%, p less than 0.001) shortly after direct current ablation but improved 4 weeks later to 43 +/- 3%. There were no significant changes in left ventricular pressure, wall motion or ejection fraction in dogs in the radiofrequency ablation group. Sustained ventricular tachycardia (greater than or equal to 30 s) was seen immediately after direct current shock in all dogs, and one dog died of intractable ventricular fibrillation. A 24-h ambulatory electrocardiographic (ECG) monitor obtained immediately after the procedure showed multiple runs of ventricular tachycardia in all dogs exposed to direct current ablation but in only three dogs that underwent radiofrequency ablation. No differences were found in peak creatine kinase, complete blood count with smear and B-beta 15-42 fibrinopeptide levels. Pathologically, direct current-induced lesions were larger (mean length x width x depth 10.9 x 7.5 x 5.2 vs. 4.8 x 4.6 x 4.3 mm) and were poorly circumscribed with inhomogeneous margins of necrosis.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1991        PMID: 1894854     DOI: 10.1016/0735-1097(91)90772-2

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  2 in total

1.  Testing the safety of Baxter continuous cardiac output monitoring system.

Authors:  P R Lichtenthal; D Gordan
Journal:  J Clin Monit       Date:  1996-05

2.  The impacts of contact force, power and application time on ablation effect indicated by serial measurements of impedance drop in both conventional and high-power short-duration ablation settings of atrial fibrillation.

Authors:  Li-Bin Shi; Yu-Chuan Wang; Song-Yun Chu; Alessandro De Bortoli; Peter Schuster; Eivind Solheim; Jian Chen
Journal:  J Interv Card Electrophysiol       Date:  2021-04-23       Impact factor: 1.759

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.