Literature DB >> 18948448

Evaluation of two methods for continuous cardiac output assessment during exercise in chronic heart failure patients.

Hareld M C Kemps1, Eric J M Thijssen, Goof Schep, Boudewijn T H M Sleutjes, Wouter R De Vries, Adwin R Hoogeveen, Pieter F F Wijn, Pieter A F M Doevendans.   

Abstract

The purpose of this study was to evaluate the accuracy of two techniques for the continuous assessment of cardiac output in patients with chronic heart failure (CHF): a radial artery pulse contour analysis method that uses an indicator dilution method for calibration (LiDCO) and an impedance cardiography technique (Physioflow), using the Fick method as a reference. Ten male CHF patients (New York Heart Association class II-III) were included. At rest, cardiac output values obtained by LiDCO and Physioflow were compared with those of the direct Fick method. During exercise, the continuous Fick method was used as a reference. Exercise, performed on a cycle ergometer in upright position, consisted of two constant-load tests at 30% and 80% of the ventilatory threshold and a symptom-limited maximal test. Both at rest and during exercise LiDCO showed good agreement with reference values [bias +/- limits of agreement (LOA), -1% +/- 28% and 2% +/- 28%, respectively]. In contrast, Physioflow overestimated reference values both at rest and during exercise (bias +/- LOA, 48% +/- 60% and 48% +/- 52%, respectively). Exercise-related within-patient changes of cardiac output, expressed as a percent change, showed for both techniques clinically acceptable agreement with reference values (bias +/- LOA: 2% +/- 26% for LiDCO, and -2% +/- 36% for Physioflow, respectively). In conclusion, although the limits of agreement with the Fick method are pretty broad, LiDCO provides accurate measurements of cardiac output during rest and exercise in CHF patients. Although Physioflow overestimates cardiac output, this method may still be useful to estimate relative changes during exercise.

Entities:  

Mesh:

Year:  2008        PMID: 18948448     DOI: 10.1152/japplphysiol.90430.2008

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  13 in total

1.  Heterogenous haemodynamic effects of adaptive servoventilation therapy in sleeping patients with heart failure and Cheyne-Stokes respiration compared to healthy volunteers.

Authors:  Jens Spießhöfer; Henrik Fox; Roman Lehmann; Christina Efken; Jessica Heinrich; Thomas Bitter; Britta Körber; Dieter Horstkotte; Olaf Oldenburg
Journal:  Heart Vessels       Date:  2015-08-22       Impact factor: 2.037

2.  Left Ventricular Function Before and After Aerobic Exercise Training in Women With Pulmonary Arterial Hypertension.

Authors:  Joshua G Woolstenhulme; Andrew A Guccione; Jeffrey E Herrick; John P Collins; Steven D Nathan; Leighton Chan; Randall E Keyser
Journal:  J Cardiopulm Rehabil Prev       Date:  2019-03       Impact factor: 2.081

3.  Cardiac output with modified cardio-impedance against inert gas rebreathing during sub-maximal and maximal cycling exercise in healthy and fit subjects.

Authors:  Alessio Del Torto; Øyvind Skattebo; Jostein Hallén; Carlo Capelli
Journal:  Eur J Appl Physiol       Date:  2018-10-17       Impact factor: 3.078

4.  Reliability of Peak Exercise Stroke Volume Assessment by Impedance Cardiography in Patients with Residual Right Outflow Tract Lesions After Congenital Heart Disease Repair.

Authors:  Antoine Legendre; D Bonnet; L Bosquet
Journal:  Pediatr Cardiol       Date:  2017-09-25       Impact factor: 1.655

5.  Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography.

Authors:  Alicia Gonzalez-Represas; Laurent Mourot
Journal:  Int J Cardiovasc Imaging       Date:  2019-12-16       Impact factor: 2.357

6.  Skeletal muscle reoxygenation after high-intensity exercise in mitochondrial myopathy.

Authors:  Daniela M Bravo; Ana Cristina Gimenes; Rúbia B Nascimento; Eloara V M Ferreira; Ana Cristina B Siqueira; Ethiane D S Meda; J Alberto Neder; Luiz Eduardo Nery
Journal:  Eur J Appl Physiol       Date:  2011-09-04       Impact factor: 3.078

7.  Estimating VO2peak in 18-90 Year-Old Adults: Development and Validation of the FitMáx©-Questionnaire.

Authors:  Renske Meijer; Martijn van Hooff; Nicole E Papen-Botterhuis; Charlotte J L Molenaar; Marta Regis; Thomas Timmers; Lonneke V van de Poll-Franse; Hans H C M Savelberg; Goof Schep
Journal:  Int J Gen Med       Date:  2022-04-05

8.  Evaluation of Impedance Cardiography for Measurement of Stroke Volume in Congenital Heart Disease.

Authors:  Mohammed Ebrahim; Sanjeet Hegde; Beth Printz; Mark Abcede; James A Proudfoot; Christopher Davis
Journal:  Pediatr Cardiol       Date:  2016-08-25       Impact factor: 1.655

Review 9.  Exercise Dynamic of Patients with Chronic Heart Failure and Reduced Ejection Fraction.

Authors:  Sara Rovai; Irene Mattavelli; Elisabetta Salvioni; Ugo Corrà; Gaia Cattadori; Jeness Campodonico; Simona Romani; Piergiuseppe Agostoni
Journal:  Curr Cardiol Rep       Date:  2021-06-29       Impact factor: 2.931

Review 10.  Invasive monitoring in patients with heart failure.

Authors:  Saima Husain; Salpy V Pamboukian; Josè A Tallaj; David C McGiffin; Robert C Bourge
Journal:  Curr Cardiol Rep       Date:  2009-05       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.