Literature DB >> 18941091

Lesion conspicuity and efficiency of CT colonography with electronic cleansing based on a three-material transition model.

Iwo W O Serlie1, Ayso H de Vries, Lucas J van Vliet, Chung Y Nio, Roel Truyen, Jaap Stoker, Franciscus M Vos.   

Abstract

OBJECTIVE: The purpose of this article is to report the effect on lesion conspicuity and the practical efficiency of electronic cleansing for CT colonography (CTC).
MATERIALS AND METHODS: Patients were included from the Walter Reed Army Medical Center public database. All patients had undergone extensive bowel preparation with fecal tagging. A primary 3D display method was used. For study I, the data consisted of all patients with polyps > or = 6 mm. Two experienced CTC observers (observer 1 and observer 2) scored the lesion conspicuity considering supine and prone positions separately. For study II, data consisted of 19 randomly chosen patients from the database. The same observers evaluated the data before and after electronic cleansing. Evaluation time, assessment effort, and observer confidence were recorded.
RESULTS: In study I, there were 59 lesions partly or completely covered by tagged material (to be uncovered by electronic cleansing) and 70 lesions surrounded by air (no electronic cleansing required). The conspicuity did not differ significantly between lesions that were uncovered by electronic cleansing and lesions surrounded by air (observer 1, p < 0.5; observer 2, p < 0.6). In study II, the median evaluation time per patient after electronic cleansing was significantly shorter than for original data (observer 1, 20 reduced to 12 minutes; observer 2, 17 reduced to 12 minutes). Assessment effort was significantly smaller for both observers (p < 0.0000001), and observer confidence was significantly larger (observer 1, p < 0.007; observer 2, p < 0.0002) after electronic cleansing.
CONCLUSION: Lesions uncovered by electronic cleansing have comparable conspicuity with lesions surrounded by air. CTC with electronic cleansing sustains a shorter evaluation time, lower assessment effort, and larger observer confidence than without electronic cleansing.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18941091     DOI: 10.2214/AJR.07.2776

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

Review 1.  Computed tomography colonography for the practicing radiologist: A review of current recommendations on methodology and clinical indications.

Authors:  Paola Scalise; Annalisa Mantarro; Francesca Pancrazi; Emanuele Neri
Journal:  World J Radiol       Date:  2016-05-28

2.  Preferences for CT colonography and colonoscopy as diagnostic tests for colorectal cancer: a discrete choice experiment.

Authors:  Kirsten Howard; Glenn Salkeld; Michael Pignone; Peter Hewett; Peter Cheung; Julie Olsen; Wayne Clapton; Ian C Roberts-Thomson
Journal:  Value Health       Date:  2011-12       Impact factor: 5.725

3.  Mosaic decomposition: an electronic cleansing method for inhomogeneously tagged regions in noncathartic CT colonography.

Authors:  Wenli Cai; June-Goo Lee; Michael E Zalis; Hiroyuki Yoshida
Journal:  IEEE Trans Med Imaging       Date:  2010-10-14       Impact factor: 10.048

Review 4.  A computer-assisted model for detection of MRI signs of Crohn's disease activity: future or fiction?

Authors:  Jeroen A W Tielbeek; Frans M Vos; Jaap Stoker
Journal:  Abdom Imaging       Date:  2012-12

5.  A simple image processing approach for electronic cleansing in computed tomographic colonography.

Authors:  S Yamamoto; G Iinuma; M Suzuki; T Tanaka; Y Muramatsu; N Moriyama
Journal:  Biomed Imaging Interv J       Date:  2009-07-01

6.  Primary uncleansed 2D versus primary electronically cleansed 3D in limited bowel preparation CT-colonography. Is there a difference for novices and experienced readers?

Authors:  Ayso H de Vries; Marjolein H Liedenbaum; Shandra Bipat; Roel Truyen; Iwo W O Serlie; Rutger H Cohen; Saskia G C van Elderen; Anneke Heutinck; Oskar Kesselring; Wouter de Monyé; Lambertus te Strake; Tjeerd Wiersma; Jaap Stoker
Journal:  Eur Radiol       Date:  2009-03-20       Impact factor: 5.315

7.  CT colonography: size reduction of submerged colorectal polyps due to electronic cleansing and CT-window settings.

Authors:  Christian Bräuer; Philippe Lefere; Stefaan Gryspeerdt; Helmut Ringl; Ali Al-Mukhtar; Paul Apfaltrer; Dominik Berzaczy; Barbara Füger; Julia Furtner; Christina Müller-Mang; Matthias Pones; Martina Scharitzer; Ramona Woitek; Anno Graser; Michael Weber; Thomas Mang
Journal:  Eur Radiol       Date:  2018-05-14       Impact factor: 5.315

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.