Literature DB >> 18926019

Chemical imaging with variable angles of incidence using a diamond attenuated total reflection accessory.

K L Andrew Chan1, Feng H Tay, Graham Poulter, Sergei G Kazarian.   

Abstract

A new development in Fourier transform infrared (FT-IR) imaging using a diamond attenuated total reflection (ATR) imaging accessory in a novel manner that allows the angle of incidence to be varied in order to obtain images from subsurface layers of different thickness is introduced. Chemical images of samples from the same area but with different depths of penetration are obtained by changing the angle of incidence as well as using different spectral bands at different wavenumbers. Changes in the angle of incidence with this accessory were made possible by taking advantage of the relatively large numerical aperture employed by the original imaging optics. This arrangement allowed us to introduce an additional movable aperture in the optical design to restrict the angle of incidence to certain values. Two samples have been studied, one for the calibration of the angle of incidence while the other demonstrates the capability of obtaining three-dimensional (3D) information using this approach. Advantages of this new approach include the relatively high spatial resolution (it can spatially resolve features as small as 12 mum without a microscope) and no change in the imaging area and sampling area during manipulation of the angle of incidence.

Year:  2008        PMID: 18926019     DOI: 10.1366/000370208786049222

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  5 in total

Review 1.  Infrared Spectroscopic Imaging Advances as an Analytical Technology for Biomedical Sciences.

Authors:  Tomasz P Wrobel; Rohit Bhargava
Journal:  Anal Chem       Date:  2018-02-06       Impact factor: 6.986

2.  In-column ATR-FTIR spectroscopy to monitor affinity chromatography purification of monoclonal antibodies.

Authors:  Maxime Boulet-Audet; Sergei G Kazarian; Bernadette Byrne
Journal:  Sci Rep       Date:  2016-07-29       Impact factor: 4.379

3.  Apparatus for High-Precision Angle-Resolved Reflection Spectroscopy in the Mid-Infrared Region.

Authors:  Takashi Kuroda; Siti Chalimah; Yuanzhao Yao; Naoki Ikeda; Yoshimasa Sugimoto; Kazuaki Sakoda
Journal:  Appl Spectrosc       Date:  2020-10-12       Impact factor: 2.388

4.  Temperature-Dependent Infrared Refractive Index of Polymers from a Calibrated Attenuated Total Reflection Infrared Measurement.

Authors:  Md S Azam; Malcolm D Ranson; Dennis K Hore
Journal:  Appl Spectrosc       Date:  2022-05-25       Impact factor: 3.588

5.  Cleaning-in-place of immunoaffinity resins monitored by in situ ATR-FTIR spectroscopy.

Authors:  Maxime Boulet-Audet; Bernadette Byrne; Sergei G Kazarian
Journal:  Anal Bioanal Chem       Date:  2015-07-10       Impact factor: 4.142

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.