Literature DB >> 1885746

Detection of tetanus antitoxin using Eu(3+)-labeled anti-human immunoglobulin G monoclonal antibodies in a time-resolved fluorescence immunoassay.

J P Schröder1, W D Kuhlmann.   

Abstract

Tetanus antitoxin in human sera was detected with solid-phase immunoassays in microtitration modules coated with tetanus toxoid by using Eu(3+)-labeled anti-human monoclonal antibodies on the basis of an exactly calibrated antibody standard. The use of a time-resolved fluorescence immunoassay (TR-FIA) significantly improved the quantitative detection of tetanus antitoxin over that of the enzyme-linked immunosorbent assay (ELISA) technique because of its high sensitivity and its wide measurement range, detecting antibody levels between 0.001 and 12.5 IU/ml with a single serum dilution of 1:100. For the same purpose, two different serum dilutions (1:100 and 1:1,000) were needed in the ELISA technique. TR-FIA is reproducible and can be performed in 3.5 h. A study of 2,630 serum samples was undertaken to examine the age-dependent distribution of titer levels, indicating the decline of sufficient protection in patients older than 60 years. The wide measurement range of TR-FIA enabled fast examination of large numbers of serum samples without the need for repetition, with further sample dilution, as was often necessary in the ELISA procedure.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1885746      PMCID: PMC270142          DOI: 10.1128/jcm.29.7.1504-1507.1991

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  20 in total

1.  [Radioimmunological measurement of tetanus antitoxin].

Authors:  G Stiffler-Rosenberg; H Fey
Journal:  Schweiz Med Wochenschr       Date:  1975-06-21

Review 2.  [Tetanus prophylactic inoculation--the indications and contraindications].

Authors:  H E Müller; M Müller; W Schiek
Journal:  Dtsch Med Wochenschr       Date:  1988-08-26       Impact factor: 0.628

3.  Evaluation of vaccination requirements to secure continuous antitoxin immunity to tetanus.

Authors:  O Simonsen; M W Bentzon; K Kjeldsen; H A Venborg; I Heron
Journal:  Vaccine       Date:  1987-06       Impact factor: 3.641

4.  [Anaphylactic reactions following active tetanus immunization].

Authors:  M Staak; E Wirth
Journal:  Dtsch Med Wochenschr       Date:  1973-01-19       Impact factor: 0.628

5.  A comparison of enzyme-linked immunosorbent assay (ELISA) with the toxin neutralization test in mice as a method for the estimation of tetanus antitoxin in human sera.

Authors:  M E Melville-Smith; V A Seagroatt; J T Watkins
Journal:  J Biol Stand       Date:  1983-04

Review 6.  Detection of viral antigens by time-resolved fluoroimmunoassay.

Authors:  P Halonen; O Meurman; T Lövgren; I Hemmilä; E Soini
Journal:  Curr Top Microbiol Immunol       Date:  1983       Impact factor: 4.291

7.  Europium as a label in time-resolved immunofluorometric assays.

Authors:  I Hemmilä; S Dakubu; V M Mukkala; H Siitari; T Lövgren
Journal:  Anal Biochem       Date:  1984-03       Impact factor: 3.365

8.  A new rapid semi-quantitative enzyme immunoassay suitable for determining immunity to tetanus.

Authors:  H M Chandler; K Healey; R R Premier; J G Hurrell
Journal:  J Infect       Date:  1984-03       Impact factor: 6.072

9.  Immunity to tetanus: tetanus antitoxin and anti-BIIb in human sera.

Authors:  M German-Fattal; B Bizzini; A German
Journal:  J Biol Stand       Date:  1987-07

10.  Detection of hepatitis B surface antigen using time-resolved fluoroimmunoassay.

Authors:  H Siitari; I Hemmilä; E Soini; T Lövgren; V Koistinen
Journal:  Nature       Date:  1983-01-20       Impact factor: 49.962

View more
  5 in total

1.  Time resolved fluorometric immunoassay, using europium labelled antihuman IgG, for the detection of human tetanus antitoxin in serum.

Authors:  P A Maple; C S Jones; N J Andrews
Journal:  J Clin Pathol       Date:  2001-10       Impact factor: 3.411

2.  Detection of Aspergillus galactomannan: comparison of an enzyme-linked immunoassay and a europium-linked time-resolved fluoroimmunoassay.

Authors:  A Paugam; J Sarfati; R Romieu; M Viguier; J Dupouy-Camet; J P Latgé
Journal:  J Clin Microbiol       Date:  1998-10       Impact factor: 5.948

3.  A lateral flow assay for the determination of human tetanus antibody in whole blood by using gold nanoparticle labeled tetanus antigen.

Authors:  Juanzu Liu; Junyan Wang; Zhaohui Li; Hongmin Meng; Lin Zhang; Hongqi Wang; Jianjun Li; Lingbo Qu
Journal:  Mikrochim Acta       Date:  2018-01-11       Impact factor: 5.833

4.  Detection of adenovirus in clinical specimens by polymerase chain reaction and liquid-phase hybridization quantitated by time-resolved fluorometry.

Authors:  J C Hierholzer; P E Halonen; P O Dahlen; P G Bingham; M M McDonough
Journal:  J Clin Microbiol       Date:  1993-07       Impact factor: 5.948

5.  A New Method for Detection African Swine Fever Virus: Time-resolved Fluorescence Immunoassay.

Authors:  Cuicui Chen; Hongrui Lai; Huankun Liang; Ying He; Guiling Guo; Laiqing Li
Journal:  J Fluoresc       Date:  2021-06-01       Impact factor: 2.217

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.