Literature DB >> 18855204

Navigated ultrasound in laparoscopic surgery.

O V Solberg1, T Langø, G A Tangen, R Mårvik, B Ystgaard, A Rethy, T A N Hernes.   

Abstract

Laparoscopic surgery is performed through small incisions that limit free sight and possibility to palpate organs. Although endoscopes provide an overview of organs inside the body, information beyond the surface of the organs is missing. Ultrasound can provide real-time essential information of inside organs, which is valuable for increased safety and accuracy in guidance of procedures. We have tested the use of 2D and 3D ultrasound combined with 3D CT data in a prototype navigation system. In our laboratory, micro-positioning sensors were integrated into a flexible intraoperative ultrasound probe, making it possible to measure the position and orientation of the real-time 2D ultrasound image as well as to perform freehand 3D ultrasound acquisitions. Furthermore, we also present a setup with the probe optically tracked from the shaft with the flexible part locked in one position. We evaluated the accuracy of the 3D laparoscopic ultrasound solution and obtained average values ranging from 1.6% to 3.6% volume deviation from the phantom specifications. Furthermore, we investigated the use of an electromagnetic tracking in the operating room. The results showed that the operating room setup disturbs the electromagnetic tracking signal by increasing the root mean square (RMS) distance error from 0.3 mm to 2.3 mm in the center of the measurement volume, but the surgical instruments and the ultrasound probe added no further inaccuracies. Tracked surgical tools, such as endoscopes, pointers, and probes, allowed surgeons to interactively control the display of both registered preoperative medical images, as well as intraoperatively acquired 3D ultrasound data, and have potential to increase the safety of guidance of surgical procedures.

Mesh:

Year:  2009        PMID: 18855204     DOI: 10.1080/13645700802383975

Source DB:  PubMed          Journal:  Minim Invasive Ther Allied Technol        ISSN: 1364-5706            Impact factor:   2.442


  12 in total

1.  Laparoscopic ultrasound: a survey of its current and future use, requirements, and integration with navigation technology.

Authors:  Cecilie Våpenstad; Anna Rethy; Thomas Langø; Tormod Selbekk; Brynjulf Ystgaard; Toril A Nagelhus Hernes; Ronald Mårvik
Journal:  Surg Endosc       Date:  2010-06-05       Impact factor: 4.584

Review 2.  Navigated laparoscopic ultrasound in abdominal soft tissue surgery: technological overview and perspectives.

Authors:  Thomas Langø; Sinara Vijayan; Anna Rethy; Cecilie Våpenstad; Ole Vegard Solberg; Ronald Mårvik; Gjermund Johnsen; Toril N Hernes
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-09-03       Impact factor: 2.924

3.  Efficacy of DynaCT for surgical navigation during complex laparoscopic surgery: an initial experience.

Authors:  Tetsuo Nozaki; Yasuyoshi Fujiuchi; Akira Komiya; Hideki Fuse
Journal:  Surg Endosc       Date:  2012-10-06       Impact factor: 4.584

4.  Design and implementation of an electromagnetic ultrasound-based navigation technique for laparoscopic ablation of liver tumors.

Authors:  Iwan Paolucci; Marius Schwalbe; Gian Andrea Prevost; Anja Lachenmayer; Daniel Candinas; Stefan Weber; Pascale Tinguely
Journal:  Surg Endosc       Date:  2018-02-12       Impact factor: 4.584

5.  Ultrasound-based tumor movement compensation during navigated laparoscopic liver interventions.

Authors:  Osama Shahin; Armin Beširević; Markus Kleemann; Alexander Schlaefer
Journal:  Surg Endosc       Date:  2014-01-03       Impact factor: 4.584

6.  Development of a multimodal tumor model for porcine liver.

Authors:  Anna Rethy; Thomas Langø; Jenny Aasland; Ronald Mårvik
Journal:  J Gastrointest Surg       Date:  2010-07-24       Impact factor: 3.452

7.  Verification of Guiding Needle Placement by Registered Ultrasound Image During Combined Intracavitary/Interstitial Gynecologic Brachytherapy.

Authors:  Jing Zeng; Ziqi Liu; Shan Jiang; Qingsong Pang; Ping Wang
Journal:  Cancer Manag Res       Date:  2021-02-24       Impact factor: 3.989

8.  Laparoscopic navigated liver resection: technical aspects and clinical practice in benign liver tumors.

Authors:  Markus Kleemann; Steffen Deichmann; Hamed Esnaashari; Armin Besirevic; Osama Shahin; Hans-Peter Bruch; Tilman Laubert
Journal:  Case Rep Surg       Date:  2012-10-22

Review 9.  CustusX: an open-source research platform for image-guided therapy.

Authors:  Christian Askeland; Ole Vegard Solberg; Janne Beate Lervik Bakeng; Ingerid Reinertsen; Geir Arne Tangen; Erlend Fagertun Hofstad; Daniel Høyer Iversen; Cecilie Våpenstad; Tormod Selbekk; Thomas Langø; Toril A Nagelhus Hernes; Håkon Olav Leira; Geirmund Unsgård; Frank Lindseth
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-09-26       Impact factor: 2.924

10.  Verification of needle guidance accuracy in pelvic phantom using registered ultrasound and MRI images for intracavitary/interstitial gynecologic brachytherapy.

Authors:  Zhiyong Yang; Ziqi Liu; Shan Jiang; Jing Zeng; Yuanjing Hu; Guobin Zhang
Journal:  J Contemp Brachytherapy       Date:  2020-04-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.