Literature DB >> 18853042

Comparison of the Polar S810i monitor and the ECG for the analysis of heart rate variability in the time and frequency domains.

L C M Vanderlei1, R A Silva, C M Pastre, F M Azevedo, M F Godoy.   

Abstract

The aim of the present study was to compare heart rate variability (HRV) at rest and during exercise using a temporal series obtained with the Polar S810i monitor and a signal from a LYNX(R) signal conditioner (BIO EMG 1000 model) with a channel configured for the acquisition of ECG signals. Fifteen healthy subjects aged 20.9 +/- 1.4 years were analyzed. The subjects remained at rest for 20 min and performed exercise for another 20 min with the workload selected to achieve 60% of submaximal heart rate. RR series were obtained for each individual with a Polar S810i instrument and with an ECG analyzed with a biological signal conditioner. The HRV indices (rMSSD, pNN50, LFnu, HFnu, and LF/HF) were calculated after signal processing and analysis. The unpaired Student t-test and intraclass correlation coefficient were used for data analysis. No statistically significant differences were observed when comparing the values analyzed by means of the two devices for HRV at rest and during exercise. The intraclass correlation coefficient demonstrated satisfactory correlation between the values obtained by the devices at rest (pNN50 = 0.994; rMSSD = 0.995; LFnu = 0.978; HFnu = 0.978; LF/HF = 0.982) and during exercise (pNN50 = 0.869; rMSSD = 0.929; LFnu = 0.973; HFnu = 0.973; LF/HF = 0.942). The calculation of HRV values by means of temporal series obtained from the Polar S810i instrument appears to be as reliable as those obtained by processing the ECG signal captured with a signal conditioner.

Mesh:

Year:  2008        PMID: 18853042     DOI: 10.1590/s0100-879x2008005000039

Source DB:  PubMed          Journal:  Braz J Med Biol Res        ISSN: 0100-879X            Impact factor:   2.590


  68 in total

1.  Assessment of heart rate variability by application of central tendency measure.

Authors:  Laurita dos Santos; Joaquim J Barroso; Elbert E N Macau; Moacir F de Godoy
Journal:  Med Biol Eng Comput       Date:  2015-09-22       Impact factor: 2.602

Review 2.  [Options and limitations of heart rate measurement and analysis of heart rate variability by mobile devices: A systematic review].

Authors:  Stefan Sammito; Irina Böckelmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-02-10

3.  Comparison of three mobile devices for measuring R-R intervals and heart rate variability: Polar S810i, Suunto t6 and an ambulatory ECG system.

Authors:  Matthias Weippert; Mohit Kumar; Steffi Kreuzfeld; Dagmar Arndt; Annika Rieger; Regina Stoll
Journal:  Eur J Appl Physiol       Date:  2010-03-12       Impact factor: 3.078

4.  The use of pupillometry in the assessment of cardiac autonomic function in elite different type trained athletes.

Authors:  Antonia Kaltsatou; Evangelia Kouidi; Dimitrios Fotiou; Pantazis Deligiannis
Journal:  Eur J Appl Physiol       Date:  2011-01-23       Impact factor: 3.078

5.  Heart rate variability and critical flicker fusion frequency changes during and after parachute jumping in experienced skydivers.

Authors:  M Cavalade; V Papadopoulou; S Theunissen; C Balestra
Journal:  Eur J Appl Physiol       Date:  2015-02-26       Impact factor: 3.078

Review 6.  Heart rate variability: are you using it properly? Standardisation checklist of procedures.

Authors:  Aparecida Maria Catai; Carlos Marcelo Pastre; Moacir Fernades de Godoy; Ester da Silva; Anielle Christine de Medeiros Takahashi; Luiz Carlos Marques Vanderlei
Journal:  Braz J Phys Ther       Date:  2019-02-26       Impact factor: 3.377

7.  The Accuracy of Acquiring Heart Rate Variability from Portable Devices: A Systematic Review and Meta-Analysis.

Authors:  Ward C Dobbs; Michael V Fedewa; Hayley V MacDonald; Clifton J Holmes; Zackary S Cicone; Daniel J Plews; Michael R Esco
Journal:  Sports Med       Date:  2019-03       Impact factor: 11.136

8.  Individual differences in cardiac vagal tone are associated with differential neural responses to facial expressions at different spatial frequencies: an ERP and sLORETA study.

Authors:  Gewnhi Park; Eunok Moon; Do-Won Kim; Seung-Hwan Lee
Journal:  Cogn Affect Behav Neurosci       Date:  2012-12       Impact factor: 3.282

9.  Heart rate variability in stroke patients submitted to an acute bout of aerobic exercise.

Authors:  Rodrigo Daminello Raimundo; Luiz Carlos de Abreu; Fernando Adami; Franciele Marques Vanderlei; Tatiana Dias de Carvalho; Isadora Lessa Moreno; Valdelias Xavier Pereira; Vitor Engracia Valenti; Monica Akemi Sato
Journal:  Transl Stroke Res       Date:  2013-05-22       Impact factor: 6.829

10.  Analysis of cardiac autonomic modulation in obese and eutrophic children.

Authors:  Luiz Carlos Marques Vanderlei; Carlos Marcelo Pastre; Ismael Forte Freitas Júnior; Moacir Fernandes de Godoy
Journal:  Clinics (Sao Paulo)       Date:  2010-06       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.