Literature DB >> 18852055

Functional and structural synergy for resolution recovery and partial volume correction in brain PET.

Miho Shidahara1, Charalampos Tsoumpas, Alexander Hammers, Nicolas Boussion, Dimitris Visvikis, Tetsuya Suhara, Iwao Kanno, Federico E Turkheimer.   

Abstract

PURPOSE: Positron Emission Tomography (PET) has the unique capability of measuring brain function but its clinical potential is affected by low resolution and lack of morphological detail. Here we propose and evaluate a wavelet synergistic approach that combines functional and structural information from a number of sources (CT, MRI and anatomical probabilistic atlases) for the accurate quantitative recovery of radioactivity concentration in PET images. When the method is combined with anatomical probabilistic atlases, the outcome is a functional volume corrected for partial volume effects.
METHODS: The proposed method is based on the multiresolution property of the wavelet transform. First, the target PET image and the corresponding anatomical image (CT/MRI/atlas-based segmented MRI) are decomposed into several resolution elements. Secondly, high-resolution components of the PET image are replaced, in part, with those of the anatomical image after appropriate scaling. The amount of structural input is weighted by the relative high frequency signal content of the two modalities. The method was validated on a digital Zubal phantom and clinical data to evaluate its quantitative potential.
RESULTS: Simulation studies showed the expected relationship between functional recovery and the amount of correct structural detail provided, with perfect recovery achieved when true images were used as anatomical reference. The use of T1-MRI images brought significant improvements in PET image resolution. However improvements were maximized when atlas-based segmented images as anatomical references were used; these results were replicated in clinical data sets.
CONCLUSION: The synergistic use of functional and structural data, and the incorporation of anatomical probabilistic information in particular, generates morphologically corrected PET images of exquisite quality.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18852055     DOI: 10.1016/j.neuroimage.2008.09.012

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  23 in total

1.  An MR image-guided, voxel-based partial volume correction method for PET images.

Authors:  Hesheng Wang; Baowei Fei
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Evaluation of a 3D local multiresolution algorithm for the correction of partial volume effects in positron emission tomography.

Authors:  Adrien Le Pogam; Mathieu Hatt; Patrice Descourt; Nicolas Boussion; Charalampos Tsoumpas; Federico E Turkheimer; Caroline Prunier-Aesch; Jean-Louis Baulieu; Denis Guilloteau; Dimitris Visvikis
Journal:  Med Phys       Date:  2011-09       Impact factor: 4.071

Review 3.  Hybrid MR-PET in Neuroimaging.

Authors:  S Bisdas; C Lá Fougere; U Ernemann
Journal:  Clin Neuroradiol       Date:  2015-07-31       Impact factor: 3.649

4.  Noise propagation in resolution modeled PET imaging and its impact on detectability.

Authors:  Arman Rahmim; Jing Tang
Journal:  Phys Med Biol       Date:  2013-09-13       Impact factor: 3.609

Review 5.  Positron emission tomography molecular imaging in late-life depression.

Authors:  Kentaro Hirao; Gwenn S Smith
Journal:  J Geriatr Psychiatry Neurol       Date:  2014-01-05       Impact factor: 2.680

Review 6.  Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

Authors:  Arman Rahmim; Jinyi Qi; Vesna Sossi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

7.  Connectivity-based functional analysis of dopamine release in the striatum using diffusion-weighted MRI and positron emission tomography.

Authors:  Andri C Tziortzi; Suzanne N Haber; Graham E Searle; Charalampos Tsoumpas; Christopher J Long; Paul Shotbolt; Gwenaelle Douaud; Saad Jbabdi; Timothy E J Behrens; Eugenii A Rabiner; Mark Jenkinson; Roger N Gunn
Journal:  Cereb Cortex       Date:  2013-01-02       Impact factor: 5.357

8.  The importance of appropriate partial volume correction for PET quantification in Alzheimer's disease.

Authors:  Benjamin A Thomas; Kjell Erlandsson; Marc Modat; Lennart Thurfjell; Rik Vandenberghe; Sebastien Ourselin; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-02-19       Impact factor: 9.236

9.  Multimodal partial volume correction: Application to [11C]PIB PET/MRI myelin imaging in multiple sclerosis.

Authors:  Elisabetta Grecchi; Mattia Veronese; Benedetta Bodini; Daniel García-Lorenzo; Marco Battaglini; Bruno Stankoff; Federico E Turkheimer
Journal:  J Cereb Blood Flow Metab       Date:  2017-06-01       Impact factor: 6.200

10.  Tau PET imaging predicts cognition in atypical variants of Alzheimer's disease.

Authors:  Jeffrey S Phillips; Sandhitsu R Das; Corey T McMillan; David J Irwin; Emily E Roll; Fulvio Da Re; Ilya M Nasrallah; David A Wolk; Murray Grossman
Journal:  Hum Brain Mapp       Date:  2017-11-06       Impact factor: 5.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.