Literature DB >> 18851794

[Interfractional and intrafractional setup errors in radiotherapy for tumors analyzed by cone-beam computed tomography].

Feng Xu1, Jin Wang, Sen Bai, Qing-Feng Xu, Ya-Li Shen, Ren-Ming Zhong.   

Abstract

BACKGROUND &
OBJECTIVE: Both interfractional and intrafractional setup errors may affect the precision of radiotherapy. This study was to analyze the interfractional and intrafractional setup errors in radiotherapy for tumors using cone-beam computed tomography(CBCT).
METHODS: Of the 51 patients received radiotherapy, 19 had head and neck tumors, 25 had thoracic tumors, and seven had abdominal-pelvic tumors. Patients received CBCT scans after initial setup, after re-positioning and after radiation delivery. The CBCT images were registered to the planning CT images, and setup errors on X,Y, Z axes were analyzed.
RESULTS: A total of 1,934 CBCT scans were performed on 51 patients, of which 955 were performed after initial setup, 525 after re-positioning and 454 after radiation delivery. The interfractional setup errors on X, Y and Z axes were (1.2+/-0.9) mm,(1.2+/-1.1) mm and (1.0+/-0.8) mm, respectively, for head and neck tumors; (2.3+/-1.9) mm, (4.2+/-3.7) mm and (2.4+/-2.1) mm, respectively, for thoracic tumors; (1.7+/-1.5) mm,(4.7+/-3.6) mm and (2.1+/-1.6) mm, respectively, for abdominal-pelvic tumors. Comparing with the post-correction position, the post-treatment setup errors in head and neck tumors increased significantly on all three axes (P < 0.05), whereas the difference was not significant in trunk tumors (P > 0.05).
CONCLUSIONS: Measurement and correction of interfractional setup errors before each fraction using CBCT could help to improve the precision of radiotherapy. The intrafractional setup error variations are obvious in head and neck tumors and should be taken into account during treatment planning. The intrafractional setup errors in trunk tumors need further study.

Entities:  

Mesh:

Year:  2008        PMID: 18851794

Source DB:  PubMed          Journal:  Ai Zheng


  6 in total

1.  The importance of image guided radiotherapy in small cell lung cancer: Case report and review of literature.

Authors:  Francisco Javier Lozano Ruiz; Sandra Ileana Pérez Álvarez; María Adela Poitevin Chacón; Federico Maldonado Magos; Rubi Ramos Prudencio; Luis Cabrera Miranda; Oscar Arrieta
Journal:  Rep Pract Oncol Radiother       Date:  2019-12-20

2.  Improved setup and positioning accuracy using a three-point customized cushion/mask/bite-block immobilization system for stereotactic reirradiation of head and neck cancer.

Authors:  He Wang; Congjun Wang; Samuel Tung; Andrew Wilson Dimmitt; Pei Fong Wong; Mark A Edson; Adam S Garden; David I Rosenthal; Clifton D Fuller; Gary B Gunn; Vinita Takiar; Xin A Wang; Dershan Luo; James N Yang; Jennifer Wong; Jack Phan
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

3.  Study to Compare the Effect of Different Registration Methods on Patient Setup Uncertainties in Cone-beam Computed Tomography during Volumetric Modulated Arc Therapy for Breast Cancer Patients.

Authors:  P Mohandass; D Khanna; T Manoj Kumar; T Thiyagaraj; C Saravanan; Narendra Kumar Bhalla; Abhishek Puri
Journal:  J Med Phys       Date:  2018 Oct-Dec

4.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375

5.  Assessment of positional reproducibility in the head and neck on a 1.5-T MR simulator for an offline MR-guided radiotherapy solution.

Authors:  Yihang Zhou; Jing Yuan; Oi Lei Wong; Winky Wing Ki Fung; Ka Fai Cheng; Kin Yin Cheung; Siu Ki Yu
Journal:  Quant Imaging Med Surg       Date:  2018-10

6.  Dosimetric impact of setup errors in head and neck cancer patients treated by image-guided radiotherapy.

Authors:  Inderjit Kaur; Sheh Rawat; Parveen Ahlawat; Anjali Kakria; Gourav Gupta; Upasna Saxena; Manindra Bhushan Mishra
Journal:  J Med Phys       Date:  2016 Apr-Jun