Hemodynamic sensing using subcutaneous photoplethysmography.

Robert G Turcott1, Todd J Pavek.   

Abstract

Pacemakers and implantable defibrillators presently operate without access to hemodynamic information. If available, such data would allow tailoring of delivered therapy according to perfusion status, optimization of device function, and enhancement of disease monitoring and management. A candidate method for hemodynamic sensing in these devices is photoplethysmography (PPG), which uses light to noninvasively detect changes in blood volume. The present study tested the hypotheses that PPG can function in a subcutaneous location, that the acute changes in blood volume it detects are directly proportional to changes in arterial pressure, and that optimum pacing intervals identified by it are concordant with those determined by arterial pressure. Aortic pressure and PPG were simultaneously recorded in 10 dogs under general anesthesia during changes in atrioventricular (AV) delay and bursts of rapid pacing to simulate tachyarrhythmias. Direct proportionality between transient changes in pressure and PPG waveforms was tested using regression analysis. Scatter plots had a linear appearance, with correlation coefficients of 0.95 (SD 0.03) and 0.72 (SD 0.24) for rapid-pacing and AV delay protocols, respectively. The data were well described by a directly proportional relationship. Optimum AV delays estimated from the induced changes in aortic pressure and PPG waveforms were concordant. This preliminary canine study demonstrates that PPG can function subcutaneously and that it may serve as a surrogate for acute changes in arterial pressure.

Entities:  

Mesh:

Year:  2008        PMID: 18849335     DOI: 10.1152/ajpheart.00574.2008

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  4 in total

1.  Measurement precision in the optimization of cardiac resynchronization therapy.

Authors:  Robert G Turcott; Ronald M Witteles; Paul J Wang; Randall H Vagelos; Michael B Fowler; Euan A Ashley
Journal:  Circ Heart Fail       Date:  2010-02-22       Impact factor: 8.790

2.  A general framework for dose optimization.

Authors:  Robert G Turcott; Hersh Sagreiya; Euan A Ashley; Russ B Altman; Amar K Das
Journal:  AMIA Annu Symp Proc       Date:  2009-11-14

3.  Identification of hemodynamically unstable arrhythmias using subcutaneous photoplethysmography.

Authors:  Robert G Turcott; Todd J Pavek
Journal:  J Cardiovasc Electrophysiol       Date:  2009-10-20

4.  Quantification of Electromechanical Coupling to Prevent Inappropriate Implantable Cardioverter-Defibrillator Shocks.

Authors:  Daniel Keene; Matthew J Shun-Shin; Ahran D Arnold; James P Howard; David Lefroy; D Wyn Davies; Phang Boon Lim; Fu Siong Ng; Michael Koa-Wing; Norman A Qureshi; Nick W F Linton; Jaymin S Shah; Nicholas S Peters; Prapa Kanagaratnam; Darrel P Francis; Zachary I Whinnett
Journal:  JACC Clin Electrophysiol       Date:  2019-03-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.