Literature DB >> 18845674

Potential clinical utility of a fibre optic-coupled dosemeter for dose measurements in diagnostic radiology.

A Kyle Jones1, David Hintenlang.   

Abstract

Many types of dosemeters have been investigated for absorbed dose measurements in diagnostic radiology, including ionisation chambers, metal-oxide semiconductor field-effect transistor dosemeters, thermoluminescent dosemeters, optically stimulated luminescence detectors, film and diodes. Each of the aforementioned dosemeters suffers from a critical limitation, either the need to interrogate, or read, the dosemeter to retrieve dose information or large size to achieve adequate sensitivity. This work presents an evaluation of a fibre optic-coupled dosemeter (FOCD) for use in diagnostic radiology dose measurement. This dosemeter is small, tissue-equivalent and capable of providing true real-time dose information. The FOCD has been evaluated for dose linearity, angular dependence, sensitivity and energy dependence at energies, beam qualities and beam quantities relevant to diagnostic radiology. The FOCD displayed excellent dose linearity and high sensitivity, while exhibiting minimal angular dependence of response. However, the dosemeter does exhibit positive energy dependence, and is subject to attenuation of response when bent.

Entities:  

Mesh:

Year:  2008        PMID: 18845674     DOI: 10.1093/rpd/ncn252

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  5 in total

1.  Validating plastic scintillation detectors for photon dosimetry in the radiologic energy range.

Authors:  Francois Lessard; Louis Archambault; Mathieu Plamondon; Philippe Despres; Franccois Therriault-Proulx; Sam Beddar; Luc Beaulieu
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

2.  Water-equivalent fiber radiation dosimeter with two scintillating materials.

Authors:  Zhuang Qin; Yaosheng Hu; Yu Ma; Wei Lin; Xianping Luo; Wenhui Zhao; Weimin Sun; Daxin Zhang; Ziyin Chen; Boran Wang; Elfed Lewis
Journal:  Biomed Opt Express       Date:  2016-11-03       Impact factor: 3.732

3.  Effects of Temperature and X-rays on Plastic Scintillating Fiber and Infrared Optical Fiber.

Authors:  Bongsoo Lee; Sang Hun Shin; Kyoung Won Jang; Wook Jae Yoo
Journal:  Sensors (Basel)       Date:  2015-05-11       Impact factor: 3.576

4.  Measurement of entrance surface dose on an anthropomorphic thorax phantom using a miniature fiber-optic dosimeter.

Authors:  Wook Jae Yoo; Sang Hun Shin; Dayeong Jeon; Seunghan Hong; Hyeok In Sim; Seon Geun Kim; Kyoung Won Jang; Seunghyun Cho; Won Sik Youn; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2014-04-01       Impact factor: 3.576

5.  Performance Evaluation of a Multichannel All-In-One Phantom Dosimeter for Dose Measurement of Diagnostic X-ray Beam.

Authors:  Hyesu Jeon; Wook Jae Yoo; Sang Hun Shin; Guwon Kwon; Mingeon Kim; Hye Jin Kim; Young Beom Song; Kyoung Won Jang; Won Sik Youn; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2015-11-11       Impact factor: 3.576

  5 in total