Literature DB >> 18839383

From high-resolution CT data to finite element models: development of an integrated modular framework.

Dieter H Pahr1, Philippe K Zysset.   

Abstract

This work introduces a novel method of automating the process of patient-specific finite element (FE) model development using a mapped mesh technique. The objective is to map a predefined mesh (template) of high quality directly onto a new bony surface (target) definition, thereby yielding a similar mesh with minimal user interaction. To bring the template mesh into correspondence with the target surface, a deformable registration technique based on the FE method has been adopted. The procedure has been made hierarchical allowing several levels of mesh refinement to be used, thus reducing the time required to achieve a solution. Our initial efforts have focused on the phalanx bones of the human hand. Mesh quality metrics, such as element volume and distortion were evaluated. Furthermore, the distance between the target surface and the final mapped mesh were measured. The results have satisfactorily proven the applicability of the proposed method.

Entities:  

Mesh:

Year:  2009        PMID: 18839383     DOI: 10.1080/10255840903065399

Source DB:  PubMed          Journal:  Comput Methods Biomech Biomed Engin        ISSN: 1025-5842            Impact factor:   1.763


  19 in total

1.  The effect of standard and low-modulus cement augmentation on the stiffness, strength, and endplate pressure distribution in vertebroplasty.

Authors:  Michael Kinzl; Lorin M Benneker; Andreas Boger; Philippe K Zysset; Dieter H Pahr
Journal:  Eur Spine J       Date:  2011-12-15       Impact factor: 3.134

Review 2.  Current progress in patient-specific modeling.

Authors:  Maxwell Lewis Neal; Roy Kerckhoffs
Journal:  Brief Bioinform       Date:  2009-12-02       Impact factor: 11.622

3.  Interactive graph-cut segmentation for fast creation of finite element models from clinical ct data for hip fracture prediction.

Authors:  Yves Pauchard; Thomas Fitze; Diego Browarnik; Amiraslan Eskandari; Irene Pauchard; William Enns-Bray; Halldór Pálsson; Sigurdur Sigurdsson; Stephen J Ferguson; Tamara B Harris; Vilmundur Gudnason; Benedikt Helgason
Journal:  Comput Methods Biomech Biomed Engin       Date:  2016-05-10       Impact factor: 1.763

4.  Expected frequency of biomechanically adverse values of proximal femur geometric variables for fracture risk in the East Slovak female population (epidemiological study).

Authors:  Jaroslava Wendlová
Journal:  Wien Med Wochenschr       Date:  2011-07-29

Review 5.  Finite Element-Based Mechanical Assessment of Bone Quality on the Basis of In Vivo Images.

Authors:  Dieter H Pahr; Philippe K Zysset
Journal:  Curr Osteoporos Rep       Date:  2016-12       Impact factor: 5.096

6.  QCT-based finite element models predict human vertebral strength in vitro significantly better than simulated DEXA.

Authors:  E Dall'Ara; D Pahr; P Varga; F Kainberger; P Zysset
Journal:  Osteoporos Int       Date:  2011-02-23       Impact factor: 4.507

Review 7.  A review of trabecular bone functional adaptation: what have we learned from trabecular analyses in extant hominoids and what can we apply to fossils?

Authors:  Tracy L Kivell
Journal:  J Anat       Date:  2016-02-16       Impact factor: 2.610

8.  Modelling of bone fracture and strength at different length scales: a review.

Authors:  Fereshteh A Sabet; Ahmad Raeisi Najafi; Elham Hamed; Iwona Jasiuk
Journal:  Interface Focus       Date:  2016-02-06       Impact factor: 3.906

9.  Metacarpal trabecular bone varies with distinct hand-positions used in hominid locomotion.

Authors:  Christopher J Dunmore; Tracy L Kivell; Ameline Bardo; Matthew M Skinner
Journal:  J Anat       Date:  2019-05-17       Impact factor: 2.610

10.  Finite element analysis for prediction of bone strength.

Authors:  Philippe K Zysset; Enrico Dall'ara; Peter Varga; Dieter H Pahr
Journal:  Bonekey Rep       Date:  2013-08-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.