Literature DB >> 18838411

Quantitative assessment of lens opacities with anterior segment optical coherence tomography.

A L Wong1, C K-S Leung, R N Weinreb, A K C Cheng, C Y L Cheung, P T-H Lam, C P Pang, D S C Lam.   

Abstract

AIM: To evaluate the reliability of lens density measurement with anterior segment optical coherence tomography (OCT) and its association with the Lens Opacity Classification System Version III (LOCS III) grading.
METHODS: Fifty-five eyes from 55 age-related cataract patients were included. One eye from each subject was selected at random for lens evaluation. After dilation, lens photographs were taken with a slit lamp and graded against the LOCS III standardised condition. Anterior segment OCT imaging was performed on the same eyes with a high-resolution scan. The association between the anterior segment OCT nucleus density measurement and LOCS III nuclear opalescence (NO) and nuclear colour (NC) scores was evaluated with the Spearman correlation coefficient. Anterior segment OCT measurement precision, coefficient of variation (CVw), and intraclass correlation coefficient (ICC) were calculated.
RESULTS: The mean NO and NC scores were 3.39 (SD 1.10) and 3.37 (SD 1.27), respectively. Significant correlations were found between anterior segment OCT nuclear density measurements and the LOCS III NO and NC scores (r = 0.77 and 0.60, respectively, both with p<0.001). The precision, CVw and ICC of anterior segment OCT measurement were 2.05 units, 4.55% and 0.98, respectively.
CONCLUSION: Anterior segment OCT nucleus density measurement is reliable and correlates with the LOCS III NO and NC scores.

Entities:  

Mesh:

Year:  2008        PMID: 18838411     DOI: 10.1136/bjo.2008.137653

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  20 in total

1.  Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography.

Authors:  Nikoo Hamzeh; Sasan Moghimi; Golshan Latifi; Massood Mohammadi; Nassim Khatibi; Shan C Lin
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

2.  Exploring the possibility of early cataract diagnostics based on tryptophan fluorescence.

Authors:  Dmitry M Gakamsky; Bal Dhillon; John Babraj; Matthew Shelton; S Desmond Smith
Journal:  J R Soc Interface       Date:  2011-04-20       Impact factor: 4.118

3.  A comparative evaluation of cataract classifications based on shear-wave elastography and B-mode ultrasound findings.

Authors:  Mesut Ozgokce; Muhammed Batur; Muhammed Alpaslan; Alpaslan Yavuz; Abdussamet Batur; Erbil Seven; Harun Arslan
Journal:  J Ultrasound       Date:  2019-09-03

4.  Anterior Segment Optical Coherence Tomography: Applications for Clinical Care and Scientific Research.

Authors:  Jing Shan; Charles DeBoer; Benjamin Y Xu
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019-04-25

5.  Correlation between different Scheimpflug-based lens densitometry analysis and effective phacoemulsification time in mild nuclear cataracts.

Authors:  Fernando Faria-Correia; Bernardo Lopes; Tiago Monteiro; Nuno Franqueira; Renato Ambrósio
Journal:  Int Ophthalmol       Date:  2017-05-26       Impact factor: 2.031

6.  The common modification in alphaA-crystallin in the lens, N101D, is associated with increased opacity in a mouse model.

Authors:  Ratna Gupta; Chinwe O Asomugha; Om P Srivastava
Journal:  J Biol Chem       Date:  2011-01-18       Impact factor: 5.157

7.  Mixed pyramid attention network for nuclear cataract classification based on anterior segment OCT images.

Authors:  Xiaoqing Zhang; Zunjie Xiao; Xiaoling Li; Xiao Wu; Hanxi Sun; Jin Yuan; Risa Higashita; Jiang Liu
Journal:  Health Inf Sci Syst       Date:  2022-03-25

8.  Clinical applications of Scheimpflug imaging in cataract surgery.

Authors:  Dilraj Singh Grewal; Satinder Pal Singh Grewal
Journal:  Saudi J Ophthalmol       Date:  2012-01

9.  Volumetric macro- and micro-scale assessment of crystalline lens opacities in cataract patients using long-depth-range swept source optical coherence tomography.

Authors:  Ireneusz Grulkowski; Silvestre Manzanera; Lukasz Cwiklinski; Juan Mompeán; Alberto de Castro; Jose Maria Marin; Pablo Artal
Journal:  Biomed Opt Express       Date:  2018-07-24       Impact factor: 3.732

10.  Assessing the correlation between swept-source optical coherence tomography lens density pattern analysis and best-corrected visual acuity in patients with cataracts.

Authors:  Hugo Bourdon; Liem Trinh; Mathieu Robin; Christophe Baudouin
Journal:  BMJ Open Ophthalmol       Date:  2021-05-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.