Literature DB >> 18835691

Modular femoral stem-sleeve junction failure after primary total hip arthroplasty.

Amar Patel1, James Bliss, Ryan P Calfee, John Froehlich, Richard Limbird.   

Abstract

The total hip prosthesis has evolved from the initial monoblock system developed by Charnley. Modularity of both the femoral and acetabular components, which allows the surgeon to assemble the prostheses just before or during the course of implantation, has now become standard. Modularity increases the number of implant parameter variables, allowing semicustom devices to be constructed. Component interfaces, however, are subject to significant stresses, micromotion manifesting as fretting, may produce wear debris, and at times may experience macromotion leading to catastrophic failure. We report 3 cases of stem-sleeve junction failure in otherwise uncomplicated primary total hip arthroplasties. Two of the failures occurred in the S-ROM (Joint Medical Products, Stamford, Conn) femoral stem design and the other in an Apex stem (Omni Life Science, Raynham, Mass). To our knowledge, there have been no previous reports of clinical failures at femoral stem-sleeve junction.

Entities:  

Mesh:

Year:  2008        PMID: 18835691     DOI: 10.1016/j.arth.2008.09.006

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Fracture of a modular femoral neck after total hip arthroplasty: a case report.

Authors:  Geoffrey Wright; Scott Sporer; Robert Urban; Joshua Jacobs
Journal:  J Bone Joint Surg Am       Date:  2010-06       Impact factor: 5.284

2.  Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.

Authors:  Feras Waly; Fahad H Abduljabbar; Trevor Gascoyne; Thomas R Turgeon; Olga Huk
Journal:  HSS J       Date:  2015-07-09

3.  Modular femoral sleeve and stem implant provides long-term total hip survivorship.

Authors:  David Le; Karen Smith; Dylan Tanzer; Michael Tanzer
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  Fatigue performance of medical Ti6Al4V alloy after mechanical surface treatments.

Authors:  Robert Sonntag; Jörn Reinders; Jens Gibmeier; J Philippe Kretzer
Journal:  PLoS One       Date:  2015-03-30       Impact factor: 3.240

5.  Failure of Emperion modular femoral stem with implant analysis.

Authors:  Benjamin M Stronach; Michael D Roach; Kenneth R St John
Journal:  Arthroplast Today       Date:  2016-01-11

6.  Total Hip Arthroplasty Using the S-ROM-A Prosthesis for Anatomically Difficult Asian Patients.

Authors:  Akira Hozumi; Kyousuke Kobayashi; Nobuhisa Tsuru; Chikara Miyamoto; Jyunichiro Maeda; Ko Chiba; Hisataka Goto; Makoto Osaki
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

7.  Fracture of an S-ROM stem at the sleeve-stem junction.

Authors:  Kilian Rueckl; Friedrich Boettner; Ulrich Bechler; Elexis C Baral; Timothy M Wright; Peter K Sculco
Journal:  Arthroplast Today       Date:  2018-05-10

8.  Fracture of a Sivash-Range of Motion Femoral Stem at the Diaphyseal Spline.

Authors:  Tyler J Humphrey; Daniel Marchwiany; Hany S Bedair; Christopher M Melnic
Journal:  Cureus       Date:  2021-12-24

9.  Femoral Stem Fracture in Hip Revision Arthroplasty: A Systematic Literature Review of the Real-World Evidence.

Authors:  Matthias Sukopp; Dominic Taylor; Raimund Forst; Frank Seehaus
Journal:  Z Orthop Unfall       Date:  2021-04-13       Impact factor: 0.923

  9 in total