Literature DB >> 18835673

Cyclodextrin-based potentiometric sensors for midazolam and diazepam.

C G Amorim1, A N Araújo, M C B S M Montenegro, V L Silva.   

Abstract

In this work the implementation of benzodiazepine ion-selective electrodes for pharmaceutical formulations control is described. The solid-contact electrodes for midazolam and diazepam are based on polymeric membranes incorporating respectively beta-cyclodextrin and (2-hydroxiproyl)-gamma-cyclodextrin as ionophores, 2-fluorophenyl 2-nitrophenyl ether as plasticizer and potassium tetrakis (p-chlorophenyl) borate as ionic additive. For conventionally shaped midazolam electrode a slope of 61.9+/-1.3 mVdec(-1), a LLLR of 5.7+/-2.7 x 10(-4)gL(-1) and pH range of 2.6-5.4 was obtained, while the corresponding values for diazepam electrodes were of 67.6+/-3.0 mVdec(-1), 4.9+/-1.5 x 10(-2)gL(-1) and 1.9-2.7 pH units, respectively. Membrane optimization was based on the molar ratio between the ionophore and additive for midazolam and on inclusion cavity of cyclodextrin for diazepam. The miniaturization of the above-described electrodes gave rise to potentiometric detectors for sequential-injection lab-on-valve system with similar characteristics albeit the useful lifetime shortened from 1 year to approximately 15 days under continuous operation. The optimized flow conditions were achieved for sample injection volumes of 20 microL propelled towards the detection cell at the flow rate of 16 microLs(-1) during 80s. Real sample analysis revealed statistical accuracy and between-days precision comparable to the general used chromatographic-based procedure.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18835673     DOI: 10.1016/j.jpba.2008.08.012

Source DB:  PubMed          Journal:  J Pharm Biomed Anal        ISSN: 0731-7085            Impact factor:   3.935


  4 in total

1.  Diazepam fluorimetric monitoring upon photo-degradation in an automatic miniaturized flow system.

Authors:  David S M Ribeiro; João A V Prior; João L M Santos; José L F C Lima
Journal:  J Fluoresc       Date:  2010-03-27       Impact factor: 2.217

2.  Ionophore-based potentiometric sensors for the flow-injection determination of promethazine hydrochloride in pharmaceutical formulations and human urine.

Authors:  Ahmed Khudhair Hassan; Bahruddin Saad; Sulaiman Ab Ghani; Rohana Adnan; Afidah Abdul Rahim; Norariza Ahmad; Marina Mokhtar; Suham Tawfiq Ameen; Suad Mustafa Al-Araji
Journal:  Sensors (Basel)       Date:  2011-01-18       Impact factor: 3.576

3.  Synthesis of dendritic silver nanostructures supported by graphene nanosheets and its application for highly sensitive detection of diazepam.

Authors:  Mir Reza Majidi; Seyran Ghaderi; Karim Asadpour-Zeynali; Hossein Dastangoo
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2015-07-23       Impact factor: 7.328

4.  Development of a Flow Injection System for Differential Pulse Amperometry and Its Application for Diazepam Determination.

Authors:  Vesna Antunović; Slavna Tešanović; Danica Perušković; Nikola Stevanović; Rada Baošić; Snežana Mandić; Aleksandar Lolić
Journal:  J Anal Methods Chem       Date:  2018-03-19       Impact factor: 2.193

  4 in total