Literature DB >> 18829940

The outcome and structural integrity of arthroscopic rotator cuff repair with use of the double-row suture anchor technique. Surgical technique.

Laurent Lafosse1, Roman Brzoska, Bruno Toussaint, Reuben Gobezie.   

Abstract

BACKGROUND: The reported rate of failure after arthroscopic rotator cuff repair has varied widely. The influence of the repair technique on the failure rates and functional outcomes after open or arthroscopic rotator cuff repair remains controversial. The purpose of the present study was to evaluate the functional and anatomic results of arthroscopic rotator cuff repairs performed with the double-row suture anchor technique on the basis of computed tomography or magnetic resonance imaging arthrography in order to determine the postoperative integrity of the repairs.
METHODS: A prospective series of 105 consecutive shoulders undergoing arthroscopic double-row rotator cuff repair of the supraspinatus or a combination of the supraspinatus and infraspinatus were evaluated at a minimum of two years after surgery. The evaluation included a routine history and physical examination as well as determination of the preoperative and postoperative strength, pain, range of motion, and Constant scores. All shoulders had a preoperative and postoperative computed tomography arthrogram (103 shoulders) or magnetic resonance imaging arthrogram (two shoulders).
RESULTS: There were thirty-six small rotator cuff tears, forty-seven large isolated supraspinatus or combined supraspinatus and infraspinatus tendon tears, and twenty-two massive rotator cuff tears. The mean Constant score (and standard deviation) was 43.2 +/- 15.1 points (range, 8 to 83 points) preoperatively and 80.1 +/- 11.1 points (range, 46 to 100 points) postoperatively. Twelve of the 105 repairs failed. Intact rotator cuff repairs were associated with significantly increased strength and active range of motion.
CONCLUSIONS: Arthroscopic repair of a rotator cuff tear with use of the double-row suture anchor technique results in a much lower rate of failure than has previously been reported in association with either open or arthroscopic repair methods. Patients with an intact rotator cuff repair have better pain relief than those with a failed repair. After repair, large and massive rotator cuff tears result in more postoperative weakness than small tears do.

Entities:  

Mesh:

Year:  2008        PMID: 18829940     DOI: 10.2106/JBJS.H.00388

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  17 in total

Review 1.  Strategies in biologic augmentation of rotator cuff repair: a review.

Authors:  Emilie V Cheung; Luz Silverio; John W Sperling
Journal:  Clin Orthop Relat Res       Date:  2010-06       Impact factor: 4.176

2.  The effect of multiple channeling on the structural integrity of repaired rotator cuff.

Authors:  Chris Hyunchul Jo; Kang Sup Yoon; Ji Ho Lee; Seung Baik Kang; Jae Hyup Lee; Hyuk Soo Han; Seung Hwan Rhee; Ji Sun Shin
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-30       Impact factor: 4.342

Review 3.  Single Vs Double row repair in rotator cuff tears - A review and analysis of current evidence.

Authors:  Al-Achraf Khoriati; Tony Antonios; Abhinav Gulihar; Bijayendra Singh
Journal:  J Clin Orthop Trauma       Date:  2019-01-30

Review 4.  [Recurrent defects of the rotary cuff : Causes and therapeutic strategies].

Authors:  M Scheibel
Journal:  Oper Orthop Traumatol       Date:  2012-11       Impact factor: 1.154

5.  Serial clinical and MRI examinations after arthroscopic rotator cuff reconstruction using double-row technique.

Authors:  F Pfalzer; J Huth; E Stürmer; D Endele; B Kniesel; F Mauch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-03-09       Impact factor: 4.342

6.  Functional outcome following arthroscopic repair of massive rotator cuff tears is equal to smaller rotator cuff tears: a retrospective case-control study.

Authors:  Jun M Leow; Oliver Krahelski; Oisin Jf Keenan; Nicholas D Clement; Julie M McBirnie
Journal:  Shoulder Elbow       Date:  2020-06-15

Review 7.  Evaluating strategies and outcomes following rotator cuff tears.

Authors:  Kelms Amoo-Achampong; Michael K Krill; Derrick Acheampong; Benedict U Nwachukwu; Frank McCormick
Journal:  Shoulder Elbow       Date:  2018-04-26

8.  Mid-term clinical outcome following rotator cuff repair using all-suture anchors.

Authors:  Baljinder Singh Dhinsa; Jagmeet Singh Bhamra; Mikel Aramberri-Gutierrez; Tony Kochhar
Journal:  J Clin Orthop Trauma       Date:  2018-02-26

9.  Advantages of arthroscopic transosseous suture repair of the rotator cuff without the use of anchors.

Authors:  Shigehito Kuroda; Noriyuki Ishige; Motohiko Mikasa
Journal:  Clin Orthop Relat Res       Date:  2013-07-09       Impact factor: 4.176

10.  Does diabetes mellitus predispose to both rotator cuff surgery and subsequent failure?

Authors:  Karch M Smith; Angela P Presson; Chong Zhang; Joshua J Horns; James M Hotaling; Robert Z Tashjian; Peter N Chalmers
Journal:  JSES Int       Date:  2021-04-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.