Literature DB >> 18814012

Functional luminal imaging probe geometric and histomorphologic analysis of abdominal wall wound induced by different trocars in pigs.

Jingbo Zhao1, Donghua Liao, Barry P McMahon, Deidre O'Donovan, Rich Schiretz, Russell Heninrich, Hans Gregersen.   

Abstract

BACKGROUND: This study aimed to investigate wound geometry and tissue damage caused by several different trocar types using a quantitative functional luminal imaging probe (FLIP) geometric profile and histomorphologic analysis.
METHODS: Four pigs were used in this study. After general anesthesia, six different trocars were randomly inserted at preselected locations in the porcine abdominal wall. The hydration status of the animals was monitored and maintained. A bag mounted on a FLIP was used to profile the geometry of the trocar holes during distension. After the FLIP study, the abdominal wall surrounding the trocar holes was harvested. The tissue was fixed in neutral 10% buffered formalin solution for more than 24 h. The samples contained control tissue (undamaged) and test tissue (damaged) through the entire rectangular tissue block. Approximately four to seven slides were cut parallel to the surface from each sample. Each slide was photographed, and the morphometry of the hole and damaged areas were measured and displayed three-dimensionally. The histologic sections were analyzed with regard to acute damage, bleeding, and acute inflammation of the skin, muscle, and fascia.
RESULTS: The FLIP study demonstrated differences between the six trocars. These were mainly due to differences between the Versaport Plus V2 bladed trocar with the smooth cannula, the Applied Medical Separator nonbladed access system with threaded cannula, and the VersaStep Plus trocar. The morphometry data showed the smallest hole and damage areas for the Versaport Plus V2 bladed trocar with the smooth cannula. The damaged area divided by the trocar hole area was smallest for the VersaStep plus trocar and the Ethicon Endopath bladed trocar with a stability cannula (p < 0.05). The histologic analysis showed that the VersaStep Plus trocar and the Ethicon Endopath bladed trocar with a stability cannula gave the least bleeding and inflammation (p < 0.05).
CONCLUSION: An agreement was found between the geometric data obtained by FLIP, the morphometric analysis, and the histology.

Entities:  

Mesh:

Year:  2008        PMID: 18814012     DOI: 10.1007/s00464-008-0105-8

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  18 in total

1.  Comparison of wounds created by non-bladed trocars and pyramidal tip trocars in the pig.

Authors:  R J Kolata; M Ransick; L Briggs; D Baum
Journal:  J Laparoendosc Adv Surg Tech A       Date:  1999-10       Impact factor: 1.878

2.  Incision characteristics associated with six laparoscopic trocar-cannula systems: a randomized, observer-blinded comparison.

Authors:  C M Tarnay; K B Glass; M G Munro
Journal:  Obstet Gynecol       Date:  1999-07       Impact factor: 7.661

3.  Intraabdominal pressure and incision parameters associated with a pyramidal laparoscopic trocar-cannula system and the EndoTIP cannula.

Authors:  Karen B Glass; Christopher M Tarnay; Malcolm G Munro
Journal:  J Am Assoc Gynecol Laparosc       Date:  2002-11

4.  Access-related complications - an analysis of 6023 consecutive laparoscopic hernia repairs.

Authors: 
Journal:  Minim Invasive Ther Allied Technol       Date:  2001-01       Impact factor: 2.442

5.  Comparison of five different abdominal access trocar systems: analysis of insertion force, removal force, and defect size.

Authors:  D M Shafer; Y Khajanchee; J Wong; L L Swanström
Journal:  Surg Innov       Date:  2006-09       Impact factor: 2.058

6.  Trocar injuries in laparoscopic surgery.

Authors:  S Bhoyrul; M A Vierra; C R Nezhat; T M Krummel; L W Way
Journal:  J Am Coll Surg       Date:  2001-06       Impact factor: 6.113

7.  Bleeding remains a major complication during laparoscopic surgery: analysis of the SALTS database.

Authors:  Isabelle Opitz; Walter Gantert; Urs Giger; Thomas Kocher; Lukas Krähenbühl
Journal:  Langenbecks Arch Surg       Date:  2005-02-08       Impact factor: 3.445

8.  Influence of different trocar tips on abdominal wall penetration during laparoscopy.

Authors:  B Böhm; M Knigge; M Kraft; K Gründel; U Boenick
Journal:  Surg Endosc       Date:  1998-12       Impact factor: 4.584

9.  The impact of trocar-cannula design and simulated operative manipulation on incisional characteristics: a randomized trial.

Authors:  Malcolm G Munro; Christopher M Tarnay
Journal:  Obstet Gynecol       Date:  2004-04       Impact factor: 7.661

10.  A comparison of the relative risk of vessel injury with conical versus pyramidal laparoscopic trocars in a rabbit model.

Authors:  W W Hurd; L Wang; M T Schemmel
Journal:  Am J Obstet Gynecol       Date:  1995-12       Impact factor: 8.661

View more
  1 in total

1.  In vivo and in situ measurement and modelling of intra-body effective complex permittivity.

Authors:  Esmaeil S Nadimi; Victoria Blanes-Vidal; Jakob L F Harslund; Mohammad H Ramezani; Jens Kjeldsen; Per Michael Johansen; David Thiel; Vahid Tarokh
Journal:  Healthc Technol Lett       Date:  2015-11-30
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.