Literature DB >> 18810480

Improved reproducibility of retinal nerve fiber layer thickness measurements with the repeat-scan protocol using the Stratus OCT in normal and glaucomatous eyes.

Argyrios Tzamalis1, Myron Kynigopoulos, Torsten Schlote, Ivan Haefliger.   

Abstract

BACKGROUND: Optical coherence tomography has become within the last years an established imaging technique with many applications in ophthalmology, and an important tool which contributes to earlier and more accurate diagnosis of glaucoma. As a consequence, detection sensitivity is highly valued. The aim of this study was to assess the reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness measurements by the Stratus Optical Coherence Tomograph (OCT) using the Fast- and Repeat-scan protocols in normal and glaucomatous eyes.
METHODS: In the clinical setting, RNFL thickness measurements were obtained from a control group of 40 subjects, consisting of 20 normal volunteers and 20 glaucoma patients. One eye was randomly chosen from each subject, and underwent five RNFL thickness measurements with the Fast- and five with the Repeat-scan protocol, which was also based on the Fast-scan mode. Reproducibility was assessed by the intraclass correlation coefficient (ICC) and the coefficient of variation (CV) for the overall mean RNFL thickness and for each quadrant and clock hour of the peripapillary area.
RESULTS: The Repeat-scan protocol yielded higher ICC and lower CV values in all quadrants and clock hours of the peripapillary area, both in normal and glaucomatous subjects. The difference in CV values between Fast- and Repeat-scan protocol measurements reached statistical significance in the temporal quadrant (P = 0.021) and in clock hour sectors 8, 9 and 12 (P = 0.022, 0.017 and 0.03 respectively). ICC (and CV) for the temporal-, superior-, nasal- and inferior-quadrant RNFL thickness was: for the Fast-scan protocol, 0.913 (7.4%), 0.925 (6.97%), 0.828 (10.31%), 0.964 (4.89%) respectively; and for the Repeat-scan protocol, 0.965 (5.08%), 0.958 (5.26%), 0.906 (8.12%) 0.968 (4.6%) respectively.
CONCLUSIONS: Reproducibility of RNFL thickness measurements with the Fast- and Repeat-scan protocols by the Stratus OCT is proved to be very high both in normal and glaucomatous subjects. The Repeat-scan protocol shows higher ICC and lower CV values, statistically significant especially on the temporal side of the peripapillary area, which may indicate a higher reproducibility and greater agreement of measurements. These findings support the fact that the Repeat-scan protocol might be considered as a more precise method for evaluation of RNFL thickness.

Entities:  

Mesh:

Year:  2008        PMID: 18810480     DOI: 10.1007/s00417-008-0946-9

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  25 in total

1.  [Reproducibility of measuring retinal nerve fiber density. Comparison of optical coherence tomography with the nerve fiber analyzer and the Heidelberg retinal tomography device].

Authors:  M Klemm; E Rumberger; A Walter; G Richard
Journal:  Ophthalmologe       Date:  2002-05       Impact factor: 1.059

2.  Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography.

Authors:  E Z Blumenthal; J M Williams; R N Weinreb; C A Girkin; C C Berry; L M Zangwill
Journal:  Ophthalmology       Date:  2000-12       Impact factor: 12.079

3.  Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT.

Authors:  Lelia A Paunescu; Joel S Schuman; Lori Lyn Price; Paul C Stark; Siobahn Beaton; Hiroshi Ishikawa; Gadi Wollstein; James G Fujimoto
Journal:  Invest Ophthalmol Vis Sci       Date:  2004-06       Impact factor: 4.799

4.  Relationship of optic disc topography to optic nerve fiber number in glaucoma.

Authors:  Y H Yücel; N Gupta; M W Kalichman; A P Mizisin; W Hare; M de Souza Lima; L Zangwill; R N Weinreb
Journal:  Arch Ophthalmol       Date:  1998-04

5.  Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography.

Authors:  Felipe A Medeiros; Linda M Zangwill; Christopher Bowd; Roberto M Vessani; Remo Susanna; Robert N Weinreb
Journal:  Am J Ophthalmol       Date:  2005-01       Impact factor: 5.258

6.  Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography.

Authors:  J S Schuman; M R Hee; C A Puliafito; C Wong; T Pedut-Kloizman; C P Lin; E Hertzmark; J A Izatt; E A Swanson; J G Fujimoto
Journal:  Arch Ophthalmol       Date:  1995-05

7.  Number of ganglion cells in glaucoma eyes compared with threshold visual field tests in the same persons.

Authors:  L A Kerrigan-Baumrind; H A Quigley; M E Pease; D F Kerrigan; R S Mitchell
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-03       Impact factor: 4.799

8.  Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes.

Authors:  Donald L Budenz; Robert T Chang; Xiangrun Huang; Robert W Knighton; James M Tielsch
Journal:  Invest Ophthalmol Vis Sci       Date:  2005-07       Impact factor: 4.799

9.  Clinically detectable nerve fiber atrophy precedes the onset of glaucomatous field loss.

Authors:  A Sommer; J Katz; H A Quigley; N R Miller; A L Robin; R C Richter; K A Witt
Journal:  Arch Ophthalmol       Date:  1991-01

10.  An evaluation of optic disc and nerve fiber layer examinations in monitoring progression of early glaucoma damage.

Authors:  H A Quigley; J Katz; R J Derick; D Gilbert; A Sommer
Journal:  Ophthalmology       Date:  1992-01       Impact factor: 12.079

View more
  9 in total

1.  Reproducibility and agreement in evaluating retinal nerve fibre layer thickness between Stratus and Spectralis OCT.

Authors:  S N Arthur; S D Smith; M M Wright; A L Grajewski; Q Wang; J M Terry; M S Lee
Journal:  Eye (Lond)       Date:  2010-11-26       Impact factor: 3.775

Review 2.  Test-retest variability in structural parameters measured with glaucoma imaging devices.

Authors:  Makoto Araie
Journal:  Jpn J Ophthalmol       Date:  2012-11-09       Impact factor: 2.447

3.  Effectiveness of averaging strategies to reduce variance in retinal nerve fibre layer thickness measurements using spectral-domain optical coherence tomography.

Authors:  Berthold Pemp; Randy H Kardon; Karl Kircher; Elisabeth Pernicka; Ursula Schmidt-Erfurth; Andreas Reitner
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-04-16       Impact factor: 3.117

4.  Helvacioglu reproducibility index: a new algorithm to evaluate the effects of misalignments on the measurements of retinal nerve fiber layer by spectral-domain OCT.

Authors:  Firat Helvacioglu; Osman Murat Uyar; Sadik Sencan; Zeki Tunc; Ziya Kapran
Journal:  Int J Ophthalmol       Date:  2015-10-18       Impact factor: 1.779

5.  Reproducibility of peripapillary retinal nerve fiber layer thickness measurements with cirrus HD-OCT in glaucomatous eyes.

Authors:  Reza Soltani-Moghadam; Yousef Alizadeh; Ehsan Kazemnezhad Leili; Mohamadreza Absari Haghighi
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

6.  Reproducibility of retinal nerve fiber layer thickness measurements using spectral domain optical coherence tomography.

Authors:  Huijuan Wu; Johannes F de Boer; Teresa C Chen
Journal:  J Glaucoma       Date:  2011-10       Impact factor: 2.503

7.  Reproducibility of retinal circulation measurements obtained using laser speckle flowgraphy-NAVI in patients with glaucoma.

Authors:  Naoko Aizawa; Yu Yokoyama; Naoki Chiba; Kazuko Omodaka; Masayuki Yasuda; Takaaki Otomo; Masahiko Nakamura; Nobuo Fuse; Toru Nakazawa
Journal:  Clin Ophthalmol       Date:  2011-08-19

8.  The effect of various factors on variability of retinal nerve fiber layer thickness measurements using optical coherence tomography.

Authors:  Dong Ju Youm; Hyunjoong Kim; Seong Hee Shim; Hyo Ju Jang; Joon Mo Kim; Ki Ho Park; Chul Young Choi; Jung Gon Cho
Journal:  Korean J Ophthalmol       Date:  2012-03-22

9.  The attenuation of retinal nerve fiber layer thickness and cognitive deterioration.

Authors:  Yuan Shen; Zhongyong Shi; Renbao Jia; Yikang Zhu; Yan Cheng; Wei Feng; Chunbo Li
Journal:  Front Cell Neurosci       Date:  2013-09-19       Impact factor: 5.505

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.