Literature DB >> 18801695

Effects of dividing the transverse carpal ligament on the mechanical behavior of the carpal bones under axial compressive load: a finite element study.

Xin Guo1, Yubo Fan, Zong-Ming Li.   

Abstract

Transecting the transverse carpal ligament (TCL) is a routine procedure to surgically treat carpal tunnel syndrome; yet, its mechanical consequences on carpal bones are unclear. In this study, our intent was to perform a computational analysis of carpal biomechanics resulting from TCL release. A three-dimensional finite element model of the wrist was constructed, which included all the carpal bones, the distal ulna and radius, the proximal metacarpals and the interosseous ligaments. Cartilage layers of each bone were modeled manually according to anatomic visualization software. The TCL was also modeled in three dimensions and added to the bone model. A 100-Newton axial load was applied to the upper section of the second and third metacarpals. The effects of dividing the TCL on the displacements of the carpal bones and the contact stress distribution in the midcarpal joints were studied using a finite element analysis method. When the TCL was divided, the axial compressive load resulted in the carpal bones deviating more radially. More specifically, the carpal bones on the radial side of the capitate and lunate (i.e. the trapezium, trapezoid, and scaphoid) moved further toward the radius, and the carpal bones on the ulnar side of the capitate and lunate (i.e. hamate, triquetrum, and pisiform) moved further toward the metacarpals. The contact stresses and contact locations in the midcarpal joints changed as a result of dividing the TCL. The changes in displacements of carpal bones and the contact stress distributions in the midcarpal joints due to TCL release may be implicated for some of the postoperative complications associated with carpal tunnel release.

Entities:  

Mesh:

Year:  2008        PMID: 18801695     DOI: 10.1016/j.medengphy.2008.08.001

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  19 in total

Review 1.  Techniques of Force and Pressure Measurement in the Small Joints of the Wrist.

Authors:  Michael J Schreck; Meghan Kelly; Colin D Canham; John C Elfar
Journal:  Hand (N Y)       Date:  2017-02-06

2.  Carpal tunnel release: do we understand the biomechanical consequences?

Authors:  Nathan T Morrell; Andrew Harris; Christian Skjong; Edward Akelman
Journal:  J Wrist Surg       Date:  2014-11

3.  Biomechanical role of the transverse carpal ligament in carpal tunnel compliance.

Authors:  Zong-Ming Li; Tamara L Marquardt; Peter J Evans; William H Seitz
Journal:  J Wrist Surg       Date:  2014-11

4.  Biomechanical analysis of the wrist arthroplasty in rheumatoid arthritis: a finite element analysis.

Authors:  M N Bajuri; Mohammed Rafiq Abdul Kadir; Malliga Raman Murali; T Kamarul
Journal:  Med Biol Eng Comput       Date:  2012-11-03       Impact factor: 2.602

5.  Subject-specific finite element analysis of the carpal tunnel cross-sectional to examine tunnel area changes in response to carpal arch loading.

Authors:  Piyush Walia; Ahmet Erdemir; Zong-Ming Li
Journal:  Clin Biomech (Bristol, Avon)       Date:  2017-01-04       Impact factor: 2.063

6.  Volar/dorsal compressive mechanical behavior of the transverse carpal ligament.

Authors:  Erin K Main; Jessica E Goetz; Thomas E Baer; Noelle F Klocke; Thomas D Brown
Journal:  J Biomech       Date:  2012-02-28       Impact factor: 2.712

7.  The pisotriquetral joint: osteoarthritis and enthesopathy.

Authors:  K E Kofman; A H Schuurman; M C Mulder; S A M W Verlinde; L M Gierman; P J van Diest; R L A W Bleys
Journal:  J Hand Microsurg       Date:  2014-04-18

8.  Finite element analysis of the wrist in stroke patients: the effects of hand grip.

Authors:  Muhammad Hanif Ramlee; Gan Kok Beng; Nazri Bajuri; Mohammed Rafiq Abdul Kadir
Journal:  Med Biol Eng Comput       Date:  2017-12-05       Impact factor: 2.602

9.  Ultrasound assessment of transverse carpal ligament thickness: a validity and reliability study.

Authors:  Zhilei Liu Shen; Zong-Ming Li
Journal:  Ultrasound Med Biol       Date:  2012-04-12       Impact factor: 2.998

10.  Three-dimensional stiffness of the carpal arch.

Authors:  Joseph N Gabra; Zong-Ming Li
Journal:  J Biomech       Date:  2015-11-18       Impact factor: 2.712

View more