Literature DB >> 18799324

Comparison of conforming and nonconforming retrieved glenoid components.

Shane J Nho1, Owen L Ala, Christopher C Dodson, Mark P Figgie, Timothy M Wright, Edward V Craig, Russell F Warren.   

Abstract

The purpose of this study was to compare differences in wear performance of conforming and nonconforming glenoid designs, using clinical, radiographic, and retrieved polyethylene glenoid component outcome Sixty-three glenoids met the study criteria, and each glenoid was assigned to the conforming group (if the radii of curvature of the humeral and glenoid components were identical) or the nonconforming group (if a mismatch existed between the radii of curvature). The mean length of implantation was 5.6 +/- 5.5 years in the conforming group and 3.1 +/- 3.1 years for the nonconforming group (P < .05). The loosening score was 3.2 +/- 2.0 in the conforming group and 2.4 +/- 1.2 in the nonconforming one (P < .05). The nonconforming group had a significantly greater burnishing score (P < .01), while the conforming group had greater abrasion and delamination scores (P < .05). Articular conformity contributes to differences observed from retrieved polyethylene glenoid components, which are consistent with differences in performance that may influence loosening.

Entities:  

Mesh:

Year:  2008        PMID: 18799324     DOI: 10.1016/j.jse.2008.04.010

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  5 in total

1.  Does an increase in modularity improve the outcomes of total shoulder replacement? Comparison across design generations.

Authors:  Bradley Schoch; Jean-David Werthel; Cathy Schleck; John W Sperling; Robert H Cofield
Journal:  Int Orthop       Date:  2015-08-06       Impact factor: 3.075

Review 2.  [Anatomical total shoulder replacement in glenohumeral osteoarthritis : Indications, current implants, and clinical results].

Authors:  O Lorbach
Journal:  Orthopade       Date:  2018-05       Impact factor: 1.087

3.  The glenoid in total shoulder arthroplasty.

Authors:  Mark Schrumpf; Travis Maak; Sommer Hammoud; Edward V Craig
Journal:  Curr Rev Musculoskelet Med       Date:  2011-12

4.  Polyethylene wear in retrieved reverse total shoulder components.

Authors:  Judd S Day; Daniel W MacDonald; Madeline Olsen; Charles Getz; Gerald R Williams; Steven M Kurtz
Journal:  J Shoulder Elbow Surg       Date:  2011-07-02       Impact factor: 3.019

5.  The effect of radial mismatch on radiographic glenoid loosening.

Authors:  Bradley S Schoch; Thomas W Wright; Joseph D Zuckerman; Pierre-Henri Flurin; Charlotte Bolch; Chris P Roche; Joseph J King
Journal:  JSES Open Access       Date:  2019-11-18
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.