Literature DB >> 18793865

Reliability and validity of a palpation technique for identifying the spinous processes of C7 and L5.

Roar Robinson1, Hilde Stendal Robinson, Gustav Bjørke, Alice Kvale.   

Abstract

The objective was to examine inter-tester reliability and validity of two therapists identifying the spinous processes (SP) of C7 and L5, using one predefined surface palpation procedure for each level. One identification method made it possible to examine the reliability and the validity of the procedure itself. Two manual therapists examined 49 patients (29 women). Aged between 26 and 79 years, 18 were cervical and 31 lumbar patients. An invisible marking pen and ultraviolet light were used, and the findings were compared. X-rays were taken as an objective measure of the correct spinal level. Percentage agreement and kappa statistics were used to evaluate reliability and validity. The best inter-therapist agreement was found for the skin marks. Percentage agreement within 10mm and 20mm was 67% and 85%, respectively. The inter-tester reliability for identifying a radiological nominated SP by palpation was found to be poor for C7 and moderate for L5, with kappa of 0.18 and 0.48, respectively. The results indicated acceptable inter-therapist surface palpation agreement, but the chosen procedures did not identify the correct SP. This indicates that the procedures are not precise enough. Future reliability studies should test other non-invasive palpation procedures, both individually and in combination, and compare these with radiological investigation.

Entities:  

Mesh:

Year:  2008        PMID: 18793865     DOI: 10.1016/j.math.2008.06.002

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  20 in total

1.  Current issues with standards in the measurement and documentation of human skeletal anatomy.

Authors:  Justin Magee; Brian McClelland; John Winder
Journal:  J Anat       Date:  2012-07-02       Impact factor: 2.610

2.  Validity of palpation of the C1 transverse process: comparison with a radiographic reference standard.

Authors:  Robert Cooperstein; Morgan Young; Makani Lew
Journal:  J Can Chiropr Assoc       Date:  2015-06

3.  Would adopting a revised landmark rule for the spinal level of the iliac crests improve the accuracy of lumbar level identification?

Authors:  Robert Cooperstein; Felisha Truong
Journal:  J Can Chiropr Assoc       Date:  2019-04

4.  Inter-tester reliability of selected clinical tests for long-lasting temporomandibular disorders.

Authors:  Elisabeth Heggem Julsvoll; Nina Køpke Vøllestad; Gro Opseth; Hilde Stendal Robinson
Journal:  J Man Manip Ther       Date:  2017-05-14

5.  Accuracy of measuring tape and vertebral-level methods to determine shoulder internal rotation.

Authors:  Seung-Hwan Han; Kyung-Soo Oh; Kyeong-Jin Han; Joon Jo; Doo-Hyung Lee
Journal:  Clin Orthop Relat Res       Date:  2011-10-01       Impact factor: 4.176

6.  Validity of sagittal thoracolumbar curvature measurement using a non-radiographic surface topography method.

Authors:  Erin Hannink; Helen Dawes; Thomas M L Shannon; Karen L Barker
Journal:  Spine Deform       Date:  2022-07-09

7.  Accuracy of Motion Palpation Flexion-Extension Test in Identifying the Seventh Cervical Spinal Process.

Authors:  Luciana C Póvoa; Ana P A Ferreira; José F C Zanier; Julio G Silva
Journal:  J Chiropr Med       Date:  2018-03-01

8.  Using Skin Markers for Spinal Curvature Quantification in Main Thoracic Adolescent Idiopathic Scoliosis: An Explorative Radiographic Study.

Authors:  Stefan Schmid; Daniel Studer; Carol-Claudius Hasler; Jacqueline Romkes; William R Taylor; Reinald Brunner; Silvio Lorenzetti
Journal:  PLoS One       Date:  2015-08-13       Impact factor: 3.240

9.  Reliability of Upper Quadrant Posture Analysis Using an Ultrasound-based Three-dimensional Motion Analyzer.

Authors:  Daisuke Uritani
Journal:  J Phys Ther Sci       Date:  2013-10-20

10.  Determination of thoracic and lumbar spinal processes by their percentage position between C7 and the PSIS level.

Authors:  Markus J Ernst; Fabian M Rast; Christoph M Bauer; Valentine L Marcar; Jan Kool
Journal:  BMC Res Notes       Date:  2013-02-11