Validity of palpation of the C1 transverse process: comparison with a radiographic reference standard.

Robert Cooperstein1, Morgan Young1, Makani Lew2.   

Abstract

OBJECTIVES: Primary goal: to determine the validity of C1 transverse process (TVP) palpation compared to an imaging reference standard.
METHODS: Radiopaque markers were affixed to the skin at the putative location of the C1 TVPs in 21 participants receiving APOM radiographs. The radiographic vertical distances from the marker to the C1 TVP, mastoid process, and C2 TVP were evaluated to determine palpatory accuracy.
RESULTS: Interexaminer agreement for radiometric analysis was "excellent." Stringent accuracy (marker placed ±4mm from the most lateral projection of the C1 TVP) = 57.1%; expansive accuracy (marker placed closer to contiguous structures) = 90.5%. Mean Absolute Deviation (MAD) = 4.34 (3.65, 5.03) mm; root-mean-squared error = 5.40mm.
CONCLUSIONS: Manual palpation of the C1 TVP can be very accurate and likely to direct a manual therapist or other health professional to the intended diagnostic or therapeutic target. This work is relevant to manual therapists, anesthetists, surgeons, and other health professionals.

Entities:  

Keywords:  C1 TVP; chiropractic; palpation; radiograph; validity

Year:  2015        PMID: 26136601      PMCID: PMC4486993     

Source DB:  PubMed          Journal:  J Can Chiropr Assoc        ISSN: 0008-3194


  43 in total

1.  The frictional properties at the thoracic skin-fascia interface: implications in spine manipulation.

Authors:  David E Bereznick; J Kim Ross; Stuart M McGill
Journal:  Clin Biomech (Bristol, Avon)       Date:  2002-05       Impact factor: 2.063

2.  Reproducibility and repeatability: errors of three groups of physiotherapists in locating spinal levels by palpation.

Authors:  E V Billis; N E Foster; C C Wright
Journal:  Man Ther       Date:  2003-11

3.  Preliminary studies with a mechanical model for the evaluation of spinal motion palpation.

Authors:  D Harvey; D Byfield
Journal:  Clin Biomech (Bristol, Avon)       Date:  1991-05       Impact factor: 2.063

4.  Transverse process of the atlas(C1)--an important surgical landmark of the upper neck.

Authors:  T S Sheen; T T Chung; C H Snyderman
Journal:  Head Neck       Date:  1997-01       Impact factor: 3.147

5.  An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-06       Impact factor: 2.571

6.  The sensitivity and specificity of seven lumbo-pelvic orthopedic tests and the arm-fossa test.

Authors:  C Leboeuf
Journal:  J Manipulative Physiol Ther       Date:  1990 Mar-Apr       Impact factor: 1.437

7.  Palpation of the upper thoracic spine: an observer reliability study.

Authors:  Henrik Wulff Christensen; Werner Vach; Kirstin Vach; Claus Manniche; Torben Haghfelt; Lisbet Hartvigsen; Poul Flemming Høilund-Carlsen
Journal:  J Manipulative Physiol Ther       Date:  2002-06       Impact factor: 1.437

8.  Determining cavitation location during lumbar and thoracic spinal manipulation: is spinal manipulation accurate and specific?

Authors:  J Kim Ross; David E Bereznick; Stuart M McGill
Journal:  Spine (Phila Pa 1976)       Date:  2004-07-01       Impact factor: 3.468

9.  Spinous process palpation using the scapular tip as a landmark vs a radiographic criterion standard.

Authors:  Robert Cooperstein; Michael T Haneline
Journal:  J Chiropr Med       Date:  2007-09

10.  Searching biomedical databases on complementary medicine: the use of controlled vocabulary among authors, indexers and investigators.

Authors:  Linda S Murphy; Sibylle Reinsch; Wadie I Najm; Vivian M Dickerson; Michael A Seffinger; Alan Adams; Shiraz I Mishra
Journal:  BMC Complement Altern Med       Date:  2003-07-07       Impact factor: 3.659

View more
  1 in total

1.  Accuracy of Motion Palpation Flexion-Extension Test in Identifying the Seventh Cervical Spinal Process.

Authors:  Luciana C Póvoa; Ana P A Ferreira; José F C Zanier; Julio G Silva
Journal:  J Chiropr Med       Date:  2018-03-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.