Literature DB >> 18791727

Does intraoperative fluoroscopic 3D imaging provide extra information for fracture surgery?

B Carelsen1, R Haverlag, D Th Ubbink, J S K Luitse, J C Goslings.   

Abstract

Fracture surgery of the extremities using 2D fluoroscopy frequently fails to detect the suboptimal positioning of implants and joint incongruities. The use of intraoperative 3D-rotational X-ray (3D-RX) imaging with a new X-ray device potentially reveals these failures. We compared 50 intraoperative (2D) results of surgery and certainty about the effectiveness of different aspects of fracture reduction as interpreted from conventional (2D) methods versus intraoperative 3D-RX in 42 distal extremity fractures by means of a surgery questionnaire. In addition, we investigated the need for revision surgery based on postoperative radiological findings in 81 patients. After fracture reduction, just before a 3D-RX scan, the surgeon preoperatively assessed the result of surgery. Three months after surgery, the 3D-RX scan was judged by three experienced surgeons independently. Intraoperative 3D-RX showed significantly more information as to screw positioning and rotation of the fracture reduction than the conventional method (p < 0.005). None of the 81 patients in whom 3D-RX was performed needed surgical revision based on postoperative radiological examinations. Intraoperative 3D-RX with this new device scanning offers additional information about extremity fracture reduction as compared to conventional intraoperative 2D imaging, and may reduce the need for revision surgery. The value of 3D-RX on functional outcomes still needs to be assessed.

Entities:  

Mesh:

Year:  2008        PMID: 18791727     DOI: 10.1007/s00402-008-0740-5

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  12 in total

1.  Is there a need for standardized postoperative radiographs after operative treatment of wrist or ankle fractures?

Authors:  Florian Oehme; Björn Christian Link; Herman Frima; Tim Schepers; Steven J Rhemrev; Reto Babst; Frank J P Beeres
Journal:  Eur J Trauma Emerg Surg       Date:  2018-07-07       Impact factor: 3.693

Review 2.  [3D safety in osteosynthesis adjacent to joints].

Authors:  J Franke; S Y Vetter; N Beisemann; B Swartman; P A Grützner; M Schnetzke
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

3.  Automatic intraoperative stitching of nonoverlapping cone-beam CT acquisitions.

Authors:  Javad Fotouhi; Bernhard Fuerst; Mathias Unberath; Stefan Reichenstein; Sing Chun Lee; Alex A Johnson; Greg M Osgood; Mehran Armand; Nassir Navab
Journal:  Med Phys       Date:  2018-04-10       Impact factor: 4.071

4.  Automatic plane adjustment of orthopedic intraoperative flat panel detector CT-volumes.

Authors:  Celia Martín Vicario; Florian Kordon; Felix Denzinger; Jan Siad El Barbari; Maxim Privalov; Jochen Franke; Sarina Thomas; Lisa Kausch; Andreas Maier; Holger Kunze
Journal:  J Med Imaging (Bellingham)       Date:  2022-05-09

5.  [Multiplanar reconstruction with mobile 3D image intensifier. Surgical treatment of proximal humerus fractures].

Authors:  P Hepp; J Theopold; J-S Jarvers; B Marquaß; N von Dercks; C Josten
Journal:  Unfallchirurg       Date:  2014-05       Impact factor: 1.000

6.  Tangential View and Intraoperative Three-Dimensional Fluoroscopy for the Detection of Screw-Misplacements in Volar Plating of Distal Radius Fractures.

Authors:  Sascha Rausch; Ivan Marintschev; Isabel Graul; Arne Wilharm; Kajetan Klos; Gunther O Hofmann; Marc Florian Gras
Journal:  Arch Trauma Res       Date:  2015-06-20

7.  Intraoperative 3D imaging in the treatment of elbow fractures--a retrospective analysis of indications, intraoperative revision rates, and implications in 36 cases.

Authors:  Marc Schnetzke; Julia Fuchs; Sven Y Vetter; Nils Beisemann; Holger Keil; Paul-Alfred Grützner; Jochen Franke
Journal:  BMC Med Imaging       Date:  2016-03-18       Impact factor: 1.930

8.  Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery.

Authors:  M S H Beerekamp; M Backes; N W L Schep; D T Ubbink; J S Luitse; T Schepers; J C Goslings
Journal:  Arch Orthop Trauma Surg       Date:  2017-09-21       Impact factor: 3.067

9.  Fluoroscopy of the Elbow: A Cadaveric Study Defining New Standard Projections to Visualize Important Anatomical Landmarks.

Authors:  Sebastian A Müller; Lars Adolfsson; Cornelia Baum; Magdalena Müller-Gerbl; Andreas M Müller; Daniel Rikli
Journal:  JB JS Open Access       Date:  2021-05-05

10.  Detection of articular perforations of the proximal humerus fracture using a mobile 3D image intensifier - a cadaver study.

Authors:  Jan Theopold; Kevin Weihs; Christine Feja; Bastian Marquaß; Christoph Josten; Pierre Hepp
Journal:  BMC Med Imaging       Date:  2017-08-01       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.