Literature DB >> 18788212

Continous quality improvement of perfusion practice: the role of electronic data collection and statistical control charts.

R A Baker1, R F Newland.   

Abstract

In-hospital data collection may be used to improve the selection, operative techniques, and process of care for cardiac surgical patients. The aim of this report is to demonstrate the influence of the automated generation of quality indicators (QI) for cardiopulmonary bypass (CPB) and the implementation of a continuous quality improvement (CQI) programme on the CPB process of care. Adult patients undergoing CPB were divided into three consecutive groups: Group 1 (n = 363); no QI data feedback, Group 2 (n = 253); automated QI data feedback alone, and Group 3 (n = 363) data feedback and implementation of CQI. There were no significant differences in demographic, procedural or clinical outcomes for each group. Significant improvement, as determined by adherence to practice protocols and reduction in practice variation, was observed for cardiac index < 1.6 L/min/m2 (min), mean arterial pressure < 40 mmHg (min), venous saturation < 60% (min), arterial blood temperature of > 37.5 degrees C (min), minimum pCO2 (mmHg), maximum pCO2 (mmHg), and minimum pO2 (mmHg). There was no change in the minimum haemoglobin (g/dl) on bypass. Automated generation of QI resulted in improved adherence to process of care guidelines, highlighting the potential of electronic data collection. This technique is optimised in a CQI programme, utilising statistical control charts for data interpretation.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18788212     DOI: 10.1177/0267659108093853

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  12 in total

1.  Perfusion Electronic Record Documentation Using Epic Systems Software.

Authors:  Jeffrey B Riley; George A Justison
Journal:  J Extra Corpor Technol       Date:  2015-12

2.  Implementing change in perfusion practice: quality improvement vs. experimentation?

Authors:  Richard F Newland; Robert A Baker
Journal:  J Extra Corpor Technol       Date:  2009-12

Review 3.  Blood Conservation-A Team Sport.

Authors:  Donald S Likosky; Timothy A Dickinson; Theron A Paugh
Journal:  J Extra Corpor Technol       Date:  2016-09

4.  Integration of Electronic Perfusion Data for Perfusion Registries.

Authors:  Richard F Newland; Robert A Baker; Chris A Barratt
Journal:  J Extra Corpor Technol       Date:  2018-06

5.  Improving cardiopulmonary bypass: does continuous blood gas monitoring have a role to play?

Authors:  Jane Ottens; Sigrid C Tuble; Andrew J Sanderson; John L Knight; Robert A Baker
Journal:  J Extra Corpor Technol       Date:  2010-09

6.  Alternative Input for Perfusion Management Devices: Voice Recognition for Data Input and the Effects on Charting and Perioperative Calculation Use.

Authors:  Kara Lung; Brandi Brummer; Scott Sanderson; David W Holt
Journal:  J Extra Corpor Technol       Date:  2021-12

7.  Perfusion quality improvement and the reduction of clinical variability.

Authors:  Alfred H Stammers; Cody C Trowbridge; James Pezzuto; Alfred Casale
Journal:  J Extra Corpor Technol       Date:  2009-12

Review 8.  How Well Is Quality Improvement Described in the Perioperative Care Literature? A Systematic Review.

Authors:  Emma L Jones; Nicholas Lees; Graham Martin; Mary Dixon-Woods
Journal:  Jt Comm J Qual Patient Saf       Date:  2016-05

9.  Australian and New Zealand perfusion survey: management and procedure.

Authors:  Sigrid C Tuble; Timothy W Willcox; Robert A Baker
Journal:  J Extra Corpor Technol       Date:  2009-06

10.  O2 delivery and CO2 production during cardiopulmonary bypass as determinants of acute kidney injury: time for a goal-directed perfusion management?

Authors:  Filip de Somer; John W Mulholland; Megan R Bryan; Tommaso Aloisio; Guido J Van Nooten; Marco Ranucci
Journal:  Crit Care       Date:  2011-08-10       Impact factor: 9.097