Literature DB >> 18783414

Cemented CeraOne and porcelain fused to TiAdapt abutment single-implant crown restorations: a 10-year comparative follow-up study.

Torsten Jemt1.   

Abstract

BACKGROUND: Long-term data comparing cemented and noncemented single-implant restorations has not been reported. AIM: To compare clinical and radiographic performance of single-implant crown restorations made by either directly baked porcelain to custom-made TiAdapt titanium abutments (Nobel Biocare AB, Göteborg, Sweden) (test) or cement crowns onto CeraOne (Nobel Biocare AB) abutments (control) after 10 years in function.
MATERIALS AND METHODS: Altogether, 35 consecutive patients were provided with 41 turned single Brånemark System implants (Nobel Biocare AB) in the partially edentulous upper jaw. By random, 15 and 20 patients were provided with 18 test and 23 control implant crowns, respectively. Thereafter, clinical and radiographic data were collected and compared between the two groups.
RESULTS: None of the implants were found loose during the follow-up period (100%). Few clinical problems were observed, and the overall average marginal bone loss was 0.26 mm (SD 0.64) during 10 years in function. After the final tightening of the crowns, no significant differences were observed between the test and control groups (p > .05). The head of the implants was placed on an average 6.3 mm (SD 2.24) below the cement/enamel junction of the adjacent teeth (range 2.5-10.0 mm). Implants with reported mechanical and/or mucosal problems or placed more apically in relation to the adjacent teeth did not present more bone loss as compared with implants with no problems or placed more coronally, respectively (p > .05).
CONCLUSIONS: There seems to be no obvious clinical or radiographic differences between the test and control single-implant restorations during 10 years of follow-up. Occasionally, some restorations presented loose abutment screws and/or fistulas during follow-up. This implies a certain need for maintenance where a one-piece single-implant protocol (test) allows both for a simple clinical procedure at placement without cementation problems, as well as for an easy and simple maintenance of installed single implant crowns in long-term function.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18783414     DOI: 10.1111/j.1708-8208.2008.00120.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  5 in total

1.  Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment.

Authors:  Rudys Rodolfo de Jesus Tavarez; Wellington Cardoso Bonachela; Anuar Antônio Xible
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

Review 2.  Influence of implant location on the clinical outcomes of implant abutments: a systematic review and meta-analysis.

Authors:  Amr G ElHoussiney; He Zhang; Jinlin Song; Ping Ji; Lu Wang; Sheng Yang
Journal:  Clin Cosmet Investig Dent       Date:  2018-02-26

Review 3.  Retention failures in cement- and screw-retained fixed restorations on dental implants in partially edentulous arches: A systematic review with meta-analysis.

Authors:  Jatin K Jain; Rajesh Sethuraman; Sameer Chauhan; Piyush Javiya; Shreya Srivastava; Rutvik Patel; Bhagyashri Bhalani
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

4.  Five-year randomized controlled clinical study comparing cemented and screw-retained zirconia-based implant-supported single crowns.

Authors:  Riccardo D Kraus; Catharina Espuelas; Christoph H F Hämmerle; Ronald E Jung; Irena Sailer; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2022-03-03       Impact factor: 5.021

5.  Cemented versus screw-retained zirconia-based single-implant restorations: 5-year results of a randomized controlled clinical trial.

Authors:  Sofia T Lamperti; Karin Wolleb; Christoph H F Hämmerle; Ronald E Jung; Jürg Hüsler; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2022-02-02       Impact factor: 5.021

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.