Literature DB >> 18777917

Accuracy of TomoTherapy treatments for superficial target volumes.

Dennis Cheek1, John P Gibbons, Isaac I Rosen, Kenneth R Hogstrom.   

Abstract

Helical tomotherapy is a technique for delivering intensity modulated radiation therapy treatments using a continuously rotating linac. In this approach, fan beams exiting the linac are dynamically modulated in synchrony with the motion of the gantry and couch. Helical IMRT deliveries have been applied to treating surface lesions, and the purpose of this study was to evaluate the accuracy of dose calculated by the TomoTherapy HiArt treatment planning system for superficial planning target volumes (PTVs). TomoTherapy treatment plans were developed for three superficial PTVs (2-, 4-, and 6-cm deep radially by 90 degrees azimuthally by 4-cm longitudinally) contoured on a 27-cm diameter cylindrical white opaque, high-impact polystyrene phantom. The phantom included removable transverse and sagittal film cassettes that contained bare Kodak EDR2 films cut such that their edges matched the phantom surface (+/-0.05 cm). The phantom was aligned to the machine's isocenter (+/-0.05 cm) and was irradiated according to the treatment plans. Films were scanned with a Vidar film digitizer, and optical densities were converted to dose using a calibration determined from a 6 MV perpendicular film exposure. This perpendicular calibration required that axial film doses (parallel irradiation) be scaled by 1.02 so that mid-arc depth doses matched those measured in the sagittal plane (perpendicular irradiation). All film readings were scaled by 0.935 to correct for over-response due to phantom Cerenkov light. Measured dose distributions were registered to calculated ones and compared. Calculated doses overpredicted measured doses by as much as 9.5% of the prescribed dose at depths less than 1 cm. At depths greater than 1 cm, calculated dose distributions showed agreement to measurement within 5% in the high-dose region and within 0.2 cm distance-to-agreement in the dose falloff regions. In the low-dose region posterior to the PTVs (<10% of the prescribed dose), the dose algorithm underpredicted the dose by 1%-2% of the prescribed dose. Clinically, it is recommended that 1 cm of bolus be used on the surface to ensure that cancerous tissues less than 1 cm depth are not underdosed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18777917     DOI: 10.1118/1.2952362

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Dose discrepancies in the buildup region and their impact on dose calculations for IMRT fields.

Authors:  Shu-Hui Hsu; Jean M Moran; Yu Chen; Ravi Kulasekere; Peter L Roberson
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  Skin dose study of chest wall treatment with tomotherapy.

Authors:  Khosrow Javedan; Geoffrey Zhang; Richard Mueller; Eleanor Harris; Lawrence Berk; Kenneth Forster
Journal:  Jpn J Radiol       Date:  2009-11-27       Impact factor: 2.374

3.  Acute Toxicity From Breast Cancer Radiation Using Helical Tomotherapy With a Simultaneous Integrated Boost.

Authors:  Andrzej P Wojcieszynski; Anna K Olson; Yi Rong; Randall J Kimple; Poonam Yadav
Journal:  Technol Cancer Res Treat       Date:  2015-03-16

4.  Evaluation of a mixed beam therapy for postmastectomy breast cancer patients: Bolus electron conformal therapy combined with intensity modulated photon radiotherapy and volumetric modulated photon arc therapy.

Authors:  Rui Zhang; David Heins; Mary Sanders; Beibei Guo; Kenneth Hogstrom
Journal:  Med Phys       Date:  2018-05-27       Impact factor: 4.071

5.  Skin dose calculation during radiotherapy of head and neck cancer using deformable image registration of planning and mega-voltage computed tomography scans.

Authors:  Marco Branchini; Sara Broggi; Italo Dell'Oca; Giovanni Mauro Cattaneo; Riccardo Calandrino; Nadia Gisella Di Muzio; Claudio Fiorino
Journal:  Phys Imaging Radiat Oncol       Date:  2018-12-01

6.  Evaluation of skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapy.

Authors:  Fundagul Andic; Yasemin Ors; Rima Davutoglu; Sule Baz Cifci; Emine Burcin Ispir; Mehmet Ertugrul Erturk
Journal:  J Exp Clin Cancer Res       Date:  2009-03-24

7.  Feasibility of a Skin Dose Reduction for Nasopharyngeal Carcinoma Treated With High-Intensity-Modulated Delivery Techniques.

Authors:  Xiongfei Liao; Jie Li; Pei Wang; Xinghong Yao; Yulei Zhang; Tingqiang Tan; Lucia Clara Orlandini
Journal:  Technol Cancer Res Treat       Date:  2018-01-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.