Literature DB >> 18777552

High-spatial-resolution three-dimensional MR cholangiography using a high-sampling-efficiency technique (SPACE) at 3T: comparison with the conventional constant flip angle sequence in healthy volunteers.

Shigeki Arizono1, Hiroyoshi Isoda, Yoji S Maetani, Yuusuke Hirokawa, Kotaro Shimada, Yuji Nakamoto, Kaori Togashi.   

Abstract

PURPOSE: To evaluate the image quality of high-spatial-resolution three-dimensional magnetic resonance cholangiography (MRC) with a high-sampling-efficiency technique (sampling perfection with application optimized contrasts using different flip angle evolutions [SPACE]) in comparison with a conventional constant flip angle (FA) sequence at 3T.
MATERIALS AND METHODS: Eighteen volunteers were examined on a 3T MR unit using MRC imaging performed with three different free-breathing three-dimensional T2-weighted turbo spin-echo (TSE) sequences: 1) SPACE (spatial resolution, 1.1x1.0x0.84 mm), 2) constant FA (1.1x1.0x0.84 mm), and 3) SPACE at a higher resolution (SPACE HR; 1.0x0.9x0.644 mm). A five-point scale was used to compare overall image quality and visualization of the third branches of the bile duct (B2, B6, and B8). Depictions of cystic duct insertion and the highest order of bile duct visible were also compared.
RESULTS: MRC with SPACE and SPACE HR sequences produced significantly better overall image quality than the constant FA sequence. In all analyses of duct visibility, SPACE and SPACE HR sequences showed higher scores than the constant FA sequence.
CONCLUSION: High-resolution three-dimensional MRC with SPACE at 3T allows high-quality imaging of the biliary tract, and has the ability to depict nondilated intrahepatic bile ducts (IHBD) in healthy volunteers. Copyright (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 18777552     DOI: 10.1002/jmri.21484

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  9 in total

1.  Unenhanced calf MR angiography at 3.0 T using electrocardiography-gated partial-fourier fast spin echo imaging with variable flip angle.

Authors:  Dan Li; Jiang Lin; Fuhua Yan; Qingyuan Wu; Weiwei Lv; Yan San; Hong Yun
Journal:  Eur Radiol       Date:  2010-12-14       Impact factor: 5.315

2.  Three-dimensional MR Cholangiopancreatography in a Breath Hold with Sparsity-based Reconstruction of Highly Undersampled Data.

Authors:  Hersh Chandarana; Ankur M Doshi; Alampady Shanbhogue; James S Babb; Mary T Bruno; Tiejun Zhao; Esther Raithel; Michael O Zenge; Guobin Li; Ricardo Otazo
Journal:  Radiology       Date:  2016-03-16       Impact factor: 11.105

Review 3.  Advanced MR Imaging of the Pancreas.

Authors:  Danielle V Hill; Temel Tirkes
Journal:  Magn Reson Imaging Clin N Am       Date:  2020-06-03       Impact factor: 2.266

4.  Breath-held MR cholangiopancreatography (MRCP) using a 3D Dixon fat-water separated balanced steady state free precession sequence.

Authors:  James F Glockner; Manojkumar Saranathan; Ersin Bayram; Christine U Lee
Journal:  Magn Reson Imaging       Date:  2013-07-20       Impact factor: 2.546

5.  Evaluation of aqueductal patency in patients with hydrocephalus: three-dimensional high-sampling-efficiency technique (SPACE) versus two-dimensional turbo spin echo at 3 Tesla.

Authors:  Murat Ucar; Melike Guryildirim; Nil Tokgoz; Koray Kilic; Alp Borcek; Yusuf Oner; Koray Akkan; Turgut Tali
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

6.  Quantitative Analysis of Parotid Gland Secretion Function in Sjögren's Syndrome Patients with Dynamic Magnetic Resonance Sialography.

Authors:  Simin Liu; Weiwei Chen; Min Wang; Tong Wu; Lingli Dong; Chu Pan; Wenzhen Zhu
Journal:  Korean J Radiol       Date:  2019-03       Impact factor: 3.500

7.  Magnetic resonance cholangiopancreatography with compressed sensing at 1.5 T: clinical application for the evaluation of branch duct IPMN of the pancreas.

Authors:  Benjamin Henninger; Michael Steurer; Michaela Plaikner; Elisabeth Weiland; Werner Jaschke; Christian Kremser
Journal:  Eur Radiol       Date:  2020-06-18       Impact factor: 5.315

8.  Comparison of 3D MRI with high sampling efficiency and 2D multiplanar MRI for contouring in cervix cancer brachytherapy.

Authors:  Primoz Petric; Robert Hudej; Peter Rogelj; Mateja Blas; Barbara Segedin; Helena Barbara Zobec Logar; Johannes Carl Athanasios Dimopoulos
Journal:  Radiol Oncol       Date:  2012-04-11       Impact factor: 2.991

9.  Recommendations from Gynaecological (GYN) GEC-ESTRO Working Group (IV): Basic principles and parameters for MR imaging within the frame of image based adaptive cervix cancer brachytherapy.

Authors:  Johannes C A Dimopoulos; Peter Petrow; Kari Tanderup; Primoz Petric; Daniel Berger; Christian Kirisits; Erik M Pedersen; Erik van Limbergen; Christine Haie-Meder; Richard Pötter
Journal:  Radiother Oncol       Date:  2012-01-30       Impact factor: 6.280

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.