OBJECTIVE: The objective of this study was to systematically assess the optimal b value for diffusion tensor imaging and fiber tractography of the median nerve at 1.5 T. MATERIALS AND METHODS: This is a prospective study which was carried out with institutional review board approval and written informed consent from the study subjects. Fifteen healthy volunteers (seven men, eight women; mean age, 31.2 years) underwent diffusion tensor imaging of the wrist. A single-shot spin-echo-based echo-planar imaging sequence (TR/TE, 7000/103 ms) was performed in each subject at eight different b values ranging from 325 to 1,550 s/mm(2). Number and length of reconstructed fiber tracts, fiber density index (FDi), fractional anisotropy (FA), and apparent diffusion coefficient (ADC) were calculated for the median nerve. Signal-to-noise ratio (SNR) was also calculated for each acquisition. The overall image quality was assessed by two readers in consensus by ranking representative fiber tract images for each subject using a scale range from 1 to 8 (1 = best to 8 = worst image quality). RESULTS: Longest fibers were observed for b values between 675 and 1,025 s/mm(2). Maximum FDi was found at b values of 1,025 s/mm(2). FA was between 0.5 and 0.6 for all b values. ADC gradually decreased from 1.44 x 10(-3) to 0.92 x 10(-3) mm(2)/s with increasing b values. Maximum SNR +/- standard deviation (175.4 +/- 72.6) was observed at the lowest b value and decreased with increasing b values. SNR at b values of 1,025 s/mm(2) was 48.5% of the maximum SNR. Optimal fiber tract image quality was found for b values of 1,025 s/mm(2). CONCLUSIONS: The optimal b value for diffusion tensor imaging and fiber tractography of the median nerve at 1.5 T was 1,025 s/mm(2).
OBJECTIVE: The objective of this study was to systematically assess the optimal b value for diffusion tensor imaging and fiber tractography of the median nerve at 1.5 T. MATERIALS AND METHODS: This is a prospective study which was carried out with institutional review board approval and written informed consent from the study subjects. Fifteen healthy volunteers (seven men, eight women; mean age, 31.2 years) underwent diffusion tensor imaging of the wrist. A single-shot spin-echo-based echo-planar imaging sequence (TR/TE, 7000/103 ms) was performed in each subject at eight different b values ranging from 325 to 1,550 s/mm(2). Number and length of reconstructed fiber tracts, fiber density index (FDi), fractional anisotropy (FA), and apparent diffusion coefficient (ADC) were calculated for the median nerve. Signal-to-noise ratio (SNR) was also calculated for each acquisition. The overall image quality was assessed by two readers in consensus by ranking representative fiber tract images for each subject using a scale range from 1 to 8 (1 = best to 8 = worst image quality). RESULTS: Longest fibers were observed for b values between 675 and 1,025 s/mm(2). Maximum FDi was found at b values of 1,025 s/mm(2). FA was between 0.5 and 0.6 for all b values. ADC gradually decreased from 1.44 x 10(-3) to 0.92 x 10(-3) mm(2)/s with increasing b values. Maximum SNR +/- standard deviation (175.4 +/- 72.6) was observed at the lowest b value and decreased with increasing b values. SNR at b values of 1,025 s/mm(2) was 48.5% of the maximum SNR. Optimal fiber tract image quality was found for b values of 1,025 s/mm(2). CONCLUSIONS: The optimal b value for diffusion tensor imaging and fiber tractography of the median nerve at 1.5 T was 1,025 s/mm(2).
Authors: T Jaermann; G Crelier; K P Pruessmann; X Golay; T Netsch; A M C van Muiswinkel; S Mori; P C M van Zijl; A Valavanis; S Kollias; P Boesiger Journal: Magn Reson Med Date: 2004-02 Impact factor: 4.668
Authors: Jonathan A D Farrell; Bennett A Landman; Craig K Jones; Seth A Smith; Jerry L Prince; Peter C M van Zijl; Susumu Mori Journal: J Magn Reson Imaging Date: 2007-09 Impact factor: 4.813
Authors: A Ailianou; A Fitsiori; A Syrogiannopoulou; S Toso; M Viallon; L Merlini; J Y Beaulieu; M I Vargas Journal: Br J Radiol Date: 2012-02-28 Impact factor: 3.039
Authors: Lukas Filli; Marco Piccirelli; David Kenkel; Andreas Boss; Andrei Manoliu; Gustav Andreisek; Himanshu Bhat; Val M Runge; Roman Guggenberger Journal: Eur Radiol Date: 2015-09-15 Impact factor: 5.315
Authors: Julia B Breitenseher; Gottfried Kranz; Alina Hold; Dominik Berzaczy; Stefan F Nemec; Thomas Sycha; Michael Weber; Daniela Prayer; Gregor Kasprian Journal: Eur Radiol Date: 2015-02-14 Impact factor: 5.315
Authors: Roman Guggenberger; Daniel Nanz; Gilbert Puippe; Kaspar Rufibach; Lawrence M White; Marshall S Sussman; Gustav Andreisek Journal: Skeletal Radiol Date: 2011-11-04 Impact factor: 2.199
Authors: Carinna M Torgerson; Andrei Irimia; Alex D Leow; George Bartzokis; Teena D Moody; Robin G Jennings; Jeffry R Alger; John Darrell Van Horn; Lori L Altshuler Journal: Brain Imaging Behav Date: 2013-06 Impact factor: 3.978