Serial coupling of reversed-phase and hydrophilic interaction liquid chromatography to broaden the elution window for the analysis of pharmaceutical compounds.

Stefan Louw1, Alberto S Pereira, Frédéric Lynen, Melissa Hanna-Brown, Pat Sandra.   

Abstract

It is presently a common practice in drug discovery to analyse samples by reversed-phase liquid chromatography (RPLC) and hydrophilic interaction chromatography (HILIC). To increase throughput, HILIC was connected in series to RPLC by means of a T-piece with make-up flow. The first column is a 2mm I.D. column having an optimal flow between 0.1 and 0.2mL/min. Via the T-piece, the flow for the second dimension column with an I.D. of 4.6mm is adjusted to 1.5-2.0mL/min with a high acetonitrile content (i.e. >/=80%) mobile phase. Therefore, even in gradient RPLC analysis starting with a mobile phase with high water content, the HILIC column is always operated at high acetonitrile concentration which is required to obtain retention on the HILIC column. The performance of the hyphenated RPLC/HILIC set-up is illustrated with the analysis of two model samples of pharmaceutical interest. Optimization of the conditions in the HILIC dimension is discussed.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18771775     DOI: 10.1016/j.chroma.2008.08.058

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

Review 1.  Isolation and analysis of ginseng: advances and challenges.

Authors:  Lian-Wen Qi; Chong-Zhi Wang; Chun-Su Yuan
Journal:  Nat Prod Rep       Date:  2011-01-24       Impact factor: 13.423

2.  Implementation of HILIC-UV technique for the determination of moxifloxacin and fluconazole in raw materials and pharmaceutical eye gel.

Authors:  Eman Yosrey; Heba Elmansi; Zeinab A Sheribah; Mohammed El-Sayed Metwally
Journal:  Sci Rep       Date:  2022-08-04       Impact factor: 4.996

3.  Serially coupling hydrophobic interaction and reversed-phase chromatography with simultaneous gradients provides greater coverage of the metabolome.

Authors:  Jennifer Haggarty; Madalina Oppermann; Matthew J Dalby; Richard J Burchmore; Ken Cook; Stefan Weidt; Karl E V Burgess
Journal:  Metabolomics       Date:  2015-01-11       Impact factor: 4.290

4.  Automated Sequential Analysis of Hydrophilic and Lipophilic Fractions of Biological Samples: Increasing Single-Injection Chemical Coverage in Untargeted Metabolomics.

Authors:  Kristian Pirttilä; Göran Laurell; Curt Pettersson; Mikael Hedeland
Journal:  Metabolites       Date:  2021-05-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.