Abstract

The goal of this study was to compare diagnostic accuracy of radiologists viewing clinical images on a top-of-the-line medical-grade vs a top-of-the-line commercial off-the-shelf (COTS) color display with the luminance values set to simulate a display that had been in use for 1 year. A set of 50 digital radiography chest images was selected for use in the study, half containing a solitary pulmonary nodule and half nodule-free. The images were displayed twice to each of six observers, once on each display. Eye position was recorded on a subset of the images. Overall, there was a statistically significant difference (F = 4.1496, p = 0.0471) between the medical-grade color display and the COTS color display in terms of receiver operating characteristic area under the curve values, with the medical-grade display yielding higher diagnostic accuracy. Total viewing time did not differ significantly, but eye position data revealed differences, suggesting better search and decision-making efficiency with the medical-grade display. Medical-grade color displays at 1 year old yield better diagnostic and search efficiency than COTS color displays and thus are recommended for primary reading if color displays are to be used.

Mesh:

Year:  2008        PMID: 18769964      PMCID: PMC3043703          DOI: 10.1007/s10278-008-9156-6

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  12 in total

1.  Shortcomings of low-cost imaging systems for viewing computed radiographs.

Authors:  J Ricke; E L Hänninen; C Zielinski; H Amthauer; C Stroszczynski; T Liebig; M Wolf; N Hosten
Journal:  Comput Med Imaging Graph       Date:  2000 Jan-Feb       Impact factor: 4.790

2.  The influence of a perceptually linearized display on observer performance and visual search.

Authors:  E A Krupinski; H Roehrig
Journal:  Acad Radiol       Date:  2000-01       Impact factor: 3.173

3.  Receiver operating characteristic rating analysis. Generalization to the population of readers and patients with the jackknife method.

Authors:  D D Dorfman; K S Berbaum; C E Metz
Journal:  Invest Radiol       Date:  1992-09       Impact factor: 6.016

4.  [Evaluation of the display quality of different modalities in digital radiology].

Authors:  L Lehmkuhl; J Mulzer; U Teichgraeber; C Gillessen; T Ehrenstein; J Ricke
Journal:  Rofo       Date:  2004-07

5.  ROC study of four LCD displays under typical medical center lighting conditions.

Authors:  Steve Langer; Ken Fetterly; Jay Mandrekar; Scott Harmsen; Brian Bartholmai; Charles Patton; Alan Bishop; Colin McCannel
Journal:  J Digit Imaging       Date:  2006-03       Impact factor: 4.056

6.  Eye-movement study and human performance using telepathology virtual slides: implications for medical education and differences with experience.

Authors:  Elizabeth A Krupinski; Allison A Tillack; Lynne Richter; Jeffrey T Henderson; Achyut K Bhattacharyya; Katherine M Scott; Anna R Graham; Michael R Descour; John R Davis; Ronald S Weinstein
Journal:  Hum Pathol       Date:  2006-12       Impact factor: 3.466

7.  Monochrome versus color softcopy displays for teleradiology: observer performance and visual search efficiency.

Authors:  Elizabeth A Krupinski; Hans Roehrig; Jiahua Fan; Takahiro Yoneda
Journal:  Telemed J E Health       Date:  2007-12       Impact factor: 3.536

8.  Visual scanning patterns of radiologists searching mammograms.

Authors:  E A Krupinski
Journal:  Acad Radiol       Date:  1996-02       Impact factor: 3.173

9.  Visual search of mammographic images: influence of lesion subtlety.

Authors:  Elizabeth A Krupinski
Journal:  Acad Radiol       Date:  2005-08       Impact factor: 3.173

10.  Personal computer versus workstation display: observer performance in detection of wrist fractures on digital radiographs.

Authors:  Anthony J Doyle; James Le Fevre; Graeme D Anderson
Journal:  Radiology       Date:  2005-10-19       Impact factor: 11.105

View more
  10 in total

1.  Observer performance using virtual pathology slides: impact of LCD color reproduction accuracy.

Authors:  Elizabeth A Krupinski; Louis D Silverstein; Syed F Hashmi; Anna R Graham; Ronald S Weinstein; Hans Roehrig
Journal:  J Digit Imaging       Date:  2012-12       Impact factor: 4.056

2.  DICOM part 14: GSDF-calibrated medical grade monitor vs a DICOM part 14: GSDF-calibrated "commercial off-the-shelf" (COTS) monitor for viewing 8-bit dental images.

Authors:  D J McIlgorm; J P McNulty
Journal:  Dentomaxillofac Radiol       Date:  2014-11-25       Impact factor: 2.419

3.  Comparison of medical-grade and calibrated consumer-grade displays for diagnosis of subtle bone fissures.

Authors:  Daniel Pinto Dos Santos; Jonas Welter; Tilman Emrich; Florian Jungmann; Evelyn Dappa; Peter Mildenberger; Roman Kloeckner
Journal:  Eur Radiol       Date:  2017-06-28       Impact factor: 5.315

4.  Viewing your digital radiographs: which monitor is best?

Authors:  D McIlgorm
Journal:  Br Dent J       Date:  2016-04-22       Impact factor: 1.626

5.  Display evaluation for primary diagnosis using digital pathology.

Authors:  Emily L Clarke; Craig Munnings; Bethany Williams; David Brettle; Darren Treanor
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-23

Review 6.  Display Characteristics and Their Impact on Digital Pathology: A Current Review of Pathologists' Future "Microscope".

Authors:  Jacob T Abel; Peter Ouillette; Christopher L Williams; John Blau; Jerome Cheng; Keluo Yao; Winston Y Lee; Toby C Cornish; Ulysses G J Balis; David S McClintock
Journal:  J Pathol Inform       Date:  2020-08-11

7.  Reproducible Color Gamut of Hematoxylin and Eosin Stained Images in Standard Color Spaces.

Authors:  Wei-Chung Cheng
Journal:  J Pathol Inform       Date:  2020-11-06

8.  Telemedicine During COVID-19 Pandemic: Endocrine Surgery Patient Perspective.

Authors:  Mohammed W Jeraq; Michelle B Mulder; Dina Kaplan; John I Lew; Josefina C Farra
Journal:  J Surg Res       Date:  2021-12-28       Impact factor: 2.417

9.  Interpretation of digital chest radiographs: comparison of light emitting diode versus cold cathode fluorescent lamp backlit monitors.

Authors:  Hyun-ju Lim; Myung Jin Chung; Geewon Lee; Miyeon Yie; Kyung Eun Shin; Jung Won Moon; Kyung Soo Lee
Journal:  Korean J Radiol       Date:  2013-11-05       Impact factor: 3.500

Review 10.  Telemedicine Workplace Environments: Designing for Success.

Authors:  Elizabeth A Krupinski
Journal:  Healthcare (Basel)       Date:  2014-02-24
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.