Literature DB >> 18766361

Anterior segment optical coherence tomography in eye injuries.

Edward Wylegala1, Dariusz Dobrowolski, Anna Nowińska, Dorota Tarnawska.   

Abstract

BACKGROUND: To evaluate the usefulness of anterior segment optical coherence tomography (AS OCT) for initial diagnosis and for monitoring treatment results in eye injury cases.
METHODS: We examined 38 eyes of 34 patients with different types of ocular injuries: penetrating injury (eight eyes), perforating injury (two eyes), intraocular foreign body (four eyes), ocular burn (nine eyes), contusion (13 eyes), and lamellar laceration (two eyes). The mean age of the patients was 33.8 years. AS OCT examination was performed at the initial visit, directly after injury, and repeated as treatment progressed. Both anterior chamber components and corneal pachymetry were evaluated.
RESULTS: Slit-lamp examination did not provide a clear diagnosis in three eyes after contusion because of a nontransparent cornea. In one case of a 44-year-old male patient, only corneal edema was noticed during slit-lamp examination, whereas AS OCT revealed Descemet's membrane detachment. In a 17-year-old male patient with blood infiltrating the cornea, OCT revealed acute angle closure with a pupillary block. In patients with corneal burns, OCT was valuable for monitoring the corneal healing progress after amniotic membrane application. OCT was also useful for determining whether a lamellar or penetrating technique should be applied in patients that qualified for corneal transplantation. In patients with foreign bodies, AS OCT was helpful in establishing the localization and size of the foreign body.
CONCLUSIONS: AS OCT is a very valuable tool in ophthalmic departments dealing with ocular trauma, for early diagnosis and for monitoring treatment progress.

Entities:  

Mesh:

Year:  2008        PMID: 18766361     DOI: 10.1007/s00417-008-0937-x

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  19 in total

1.  Clinical use of ultrasound biomicroscopy.

Authors:  C J Pavlin; K Harasiewicz; M D Sherar; F S Foster
Journal:  Ophthalmology       Date:  1991-03       Impact factor: 12.079

2.  Imaging through opaque corneas using anterior segment optical coherence tomography.

Authors:  Julian P S Garcia; Patricia M T Garcia; Douglas E Buxton; Anthony Panarelli; Richard B Rosen
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2007 Jul-Aug

3.  Comparison of optical coherence tomography and ultrasound biomicroscopy for detection of narrow anterior chamber angles.

Authors:  Sunita Radhakrishnan; Jason Goldsmith; David Huang; Volker Westphal; David K Dueker; Andrew M Rollins; Joseph A Izatt; Scott D Smith
Journal:  Arch Ophthalmol       Date:  2005-08

4.  Optical coherence tomography for the noninvasive evaluation of the cornea.

Authors:  K Hirano; Y Ito; T Suzuki; T Kojima; S Kachi; Y Miyake
Journal:  Cornea       Date:  2001-04       Impact factor: 2.651

5.  Optical coherence tomography findings of acute traumatic maculopathy following motor vehicle accident.

Authors:  Thuan Quoc Pham; Brian Chua; Mark Gorbatov; Paul Mitchell
Journal:  Am J Ophthalmol       Date:  2006-10-23       Impact factor: 5.258

6.  Anterior segment biometry with 2 imaging technologies: very-high-frequency ultrasound scanning versus optical coherence tomography.

Authors:  David P Piñero; Ana Belén Plaza; Jorge L Alió
Journal:  J Cataract Refract Surg       Date:  2008-01       Impact factor: 3.351

7.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

8.  Detection of primary angle closure using anterior segment optical coherence tomography in Asian eyes.

Authors:  Winifred P Nolan; Jovina L See; Paul T K Chew; David S Friedman; Scott D Smith; Sunita Radhakrishnan; Ce Zheng; Paul J Foster; Tin Aung
Journal:  Ophthalmology       Date:  2006-10-27       Impact factor: 12.079

9.  Corneal imaging with anterior segment optical coherence tomography for lamellar keratoplasty procedures.

Authors:  Laurence S Lim; Han T Aung; Tin Aung; Donald T H Tan
Journal:  Am J Ophthalmol       Date:  2007-10-29       Impact factor: 5.258

10.  A standardized classification of ocular trauma.

Authors:  F Kuhn; R Morris; C D Witherspoon; K Heimann; J B Jeffers; G Treister
Journal:  Ophthalmology       Date:  1996-02       Impact factor: 12.079

View more
  14 in total

1.  Removal of intraocular foreign body in anterior chamber angle with prism contact lens and 23-gauge foreign body forceps.

Authors:  Yan-Ming Huang; Hua Yan; Jin-Hong Cai; Hai-Bo Li
Journal:  Int J Ophthalmol       Date:  2017-05-18       Impact factor: 1.779

2.  Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCT.

Authors:  Noelia Martínez-Albert; Jose J Esteve-Taboada; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-02       Impact factor: 3.117

3.  The clinical features and the factors affecting visual prognosis in pediatric open-globe ınjuries.

Authors:  Hakan Öztürk; Bediz Özen
Journal:  Int Ophthalmol       Date:  2022-05-17       Impact factor: 2.029

4.  A case of a retained intralenticular foreign body for two years.

Authors:  Mete Güler; Turgut Yilmaz; Mehmet Yigit; Gülşen Ulkü; Sermal Arslan
Journal:  Clin Ophthalmol       Date:  2010-09-07

5.  Assessment of eyebright (euphrasia officinalis L.) extract activity in relation to human corneal cells using in vitro tests.

Authors:  Roman Paduch; Anna Woźniak; Piotr Niedziela; Robert Rejdak
Journal:  Balkan Med J       Date:  2014-03-01       Impact factor: 2.021

6.  Anterior segment optical coherence tomography in intracorneal foreign body.

Authors:  Neha Goel; Bhanu P S Pangtey; Usha K Raina; Basudeb Ghosh
Journal:  Oman J Ophthalmol       Date:  2012-05

7.  Anterior segment intraocular metallic foreign body causing chronic hypopyon uveitis.

Authors:  Güler Mete; Yılmaz Turgut; Arslanhan Osman; Ulkü Gülşen; Artaş Hakan
Journal:  J Ophthalmic Inflamm Infect       Date:  2010-11-17

8.  The complementary benefit of anterior segment optical coherence tomography in penetrating keratoplasty.

Authors:  Nursal Melda Yenerel; Raciha Beril Kucumen; Ebru Gorgun
Journal:  Clin Ophthalmol       Date:  2013-07-23

9.  Complimentary imaging technologies in blunt ocular trauma.

Authors:  Anton M Kolomeyer; Bernard C Szirth; Natasha V Nayak; Albert S Khouri
Journal:  Oman J Ophthalmol       Date:  2013-05

10.  Anterior segment imaging in combat ocular trauma.

Authors:  Denise S Ryan; Rose K Sia; Marcus Colyer; Richard D Stutzman; Keith J Wroblewski; Michael J Mines; Kraig S Bower
Journal:  J Ophthalmol       Date:  2013-09-29       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.